Specifications Specifications Models SWC32B11 Net capacity (L) Color black Power Supply 220~/50 (V/Hz) Rated Input Power Power Consumption ---- (kW.·h/24h) Net Weight (kg) Gross Weight (kg) Unit Dimension (D*W*H) 510*500*845 (mm) Packing Dimension (D*W*H) 560*535*870 (mm) Container Quantity 40'HQ (PCS)
Safety precautions Safety precautions This appliance uses 220-240V~50Hz AC It is required to use separate, special for power supply. outlet with securely grounding. Failure in operation and damage to the control The power cable of this appliance is fitted with panel, thermostat or the compressor will occur if three-core (grounding) plug complying with voltage is outside the range 187-242V, unless a...
Page 5
Do not damage power cable In case of damaged power cable If the power cable or plug was damaged, it Be sure not to pull out the plug of the appliance by drawing the power cable. Be sure to directly is prohibited to continue using it.
Page 6
Do not store or use gasoline or other Do not place any electrical plugs, regulators flammable article in the vicinity of the or microwaves on top of the refrigerator. Do refrigerator to avoid fire. not use electric appliances (except those allowed by manufacturer) in side the refrigerator.
Page 7
When the refrigerator has started running, Do not spray water onto the refrigerator, or take care not to touch the cold surface of the place it in wet area where water can be freezer compartment with hand, especially easily splashed, so as to avoid influencing with wet hand.
1. Compressor 2. Condenser 3. Dry filter 4. Capillary tube 5. Evaporator 2 Brief Description of System Flow Chart Model SWC32B11 is a direct cooling single-system refrigerator. When the refrigerator is just powered on, the refrigerant flows in the sequence: 1->2->3->4->5>1...
Schematic Circuit Diagram 2 Brief Description of Control Principle Model SWC32B11 is a direct cooling single-system larder. A mechanical type of all the control is generally adopted. The thermostat directly controls the start and stop of compressor, and hence the refrigerator temperature.
Maintenance Service and Trouble Shooting Maintenance Service and Trouble Shooting 1. No cooling No cooling Check and repair according to If compressor can the section of "the compressor run after it stop to does not work". five minutes and give power. If compressor can Refrigerant leak.
Page 12
Maintenance Service and Trouble Shooting 2 The compressor doesn't stop Compressor does not stop Check and repair according to Is refrigerator the section of "No cooling". cooling? Check and repair according to Is cooling capacity the section of "Cooling capacity insufficient? is insufficient".
Page 13
Maintenance Service and Trouble Shooting 3 Cooling capacity is insufficient Cooling capacity is insufficient Check the Is the ambient thermostat is temperature low than 16°C correct? Does the Adjust and instruct refrigerant leak consumer how to use slowly? Repair...
Page 14
Maintenance Service and Trouble Shooting 4 The compressor doesn't work The compressor doesn't work. Is the interior light on when door is opened? Check the power Repair source and power Check the Is the ambient temperature thermostat is low than 16°C correct? Adjust and instruct consumer how to use...
Page 15
Maintenance Service and Trouble Shooting 5 Normal Phenomena—Not Troubles for Refrigerators In a domestic refrigerator, there is not only a complicated electric control system, but also a refrigerating system that is difficult to discern whether it is in a good working condition.
Page 16
Maintenance Service and Trouble Shooting 6 Common Troubles in Refrigerators and Their Remedies Causes for troubles occurring in refrigerators are closely related to the quality of components and workmanship in assembling by manufacturers as whether refrigerators are properly used and maintained .The parameters generally used to express the working conditions of a refrigerator include the temperature inside the refrigerator ,operation rate ,electric power consumption ,noise level ,and other functional indexes .If any one of these parameters is beyond its permissible range ,this indicates that there is a fault or...
Page 17
spring inside the compressor has broken . During the normal operation of compressor ,a slight and uniform hum sound due to undulation of electric current can be heard generally ,this is a normal phenomenon .However ,if it sounds like "tong ,tong ",i.e., an impact sound inside the compressor ,this means that a large quantity of wet vapour of refrigerant or refrigerating oil has come into the compressor cylinder ;if it sounds like "dang ,dang", a striking sound of metal parts inside the compressor ,this means that some moving parts have loosened...
Page 18
make a hasty conclusion based on only one abnormal phenomenon .It is advisable to find out two or more abnormal phenomenon ,or conduct troubleshooting comprehensively with the aid of instruments or other ways ,because several kinds of troubles may share a common abnormal phenomenon ,and two or more abnormal phenomena may occur simultaneously due to a certain trouble .With this method ,you can reject some suspicious troubles and finally make a correct judgment .
Page 19
b) In case excessive refrigerant has been charged, the liquid refrigerant that cannot evaporates in the evaporator will return to the compressor ,and thus a phenomenon of "liquid striking" will occur .The liquid refrigerant evaporates and effervesces as soon as it flows into the refrigerating oil at the bottom of compressor .If the condition is severe ,foams will fill all over inside the compressor housing and be sucked by the piston ,causing damage to the components of compressor .
Page 20
Turn the refrigerator off ,and make preparations for defrosting ,open the refrigerator door to let the air come in ,or use a fan to speed up air flowing so as to shorten the time needed for defrosting .Never strike the frost layer with any iron tools or wood stick in order to avoid damage to the evaporator tubing .
Page 21
quite a long time ,we find the leakage of refrigerant ,or in the course of its operation ,we have found that the refrigerator is gradually becoming not so cold and finally no refrigerating cab be achieved ; ii) fast leakage in that case ,all the refrigerant will escape swiftly due to abrupt rupture of system tubing .
Page 22
dirt exhibits the same symptoms as that with ice, namely, higher gas suction pressure, lower temperature of discharged gas, and no gas flowing sound from the evaporator. The difference between the both is as follows: if the clogging is caused by dirt , tapping the suspicious clogged point (generally in the capillary or the connection joint of the filter) may cause the refrigerant to flow through partially, resulting in some corresponding change, whereas in that case if you heat it with a hot towel, no reaction will happen, no flowing...
Page 23
1) Stoppage due to excessively high gas discharge pressure A) Too much refrigerant charged into the system Analysis of Trouble The phenomenon, such as loose frosting and poor refrigerating effect, may occur if excessive refrigerant has been charged into the system. Superfluous refrigerant will occupy a certain space of the evaporator, thus reduce its heat dissipating area, and the phenomenon of "liquid striking"...
Page 24
exceeds its refrigerating capacity ; or in case the power supply voltage drops considerably, the current flowing through the motor will increase drastically making the thermal protector actuate and the fuse blown , and hence the motor stops running. If the motor is still running continuously in such a case , its windings will be burned out .
Page 25
Remedy Measure the voltage with a voltmeter, if it is really too low, give directions to the user for buying a stabilizer so as to step up the voltage, thus normal operation can be achieved. 3) Check the thermal relay to see whether its contacts are closed. Analysis of Trouble The contacts of thermal relay sometimes may be open due to the leakage of temperature sensing agent from the temperature sensor.
Page 26
lubricant, clogging in the lubricant oil line, or intermittent lubricant oil supply. Dirt and other impurities in the lubricant oil will increase its viscosity and cause the shaft to be seized. Copper plating may also result in seizing of shaft. b) Seizing of piston This is caused by too small fit clearance between the piston and cylinder or expansion due to heat.
Page 27
4) No stoppage of compressor due to damaged heat-insulation layer inside case body and/or door seal Analysis of Trouble When the heat-insulation layer inside the case body deteriorates or the door seal is not closely touches the door frame, the temperature in the refrigerator will rise and makes the compressor running continuously.
Page 28
If the leveling screws on refrigerator legs have not been adjusted properly ,vibration and noise will still occur even if the refrigerator has been placed on a level ground . 2) Abnormal noise from compressor Three suspended spring inside the compressor case are out of balance ,and strike against the case ,moreover ,the wear of compressor parts may cause noise sometimes .
Need help?
Do you have a question about the SWC32B11 and is the answer not in the manual?
Questions and answers