  • Page 1 Portable Air Conditioner Models: AP14000HS & AP14000W Owner’s Manual For more information on other great EdgeStar products on the web, go to http://www.edgestar.com...
  • Page 2: Important Safety Information

    2. Press the TEST button on the LCDI plug. This should trip the plug and cut the power to the air conditioner. If the plug does not trip and you are able to turn on the unit, please contact EdgeStar support.
  • Page 3: Table Of Contents

    LEANING THE UNIT ... 19 LEANING THE PRE FILTER ... 19 REPARATION FOR TORAGE TROUBLESHOOTING ... 20 ROUBLESHOOTING CONTINUED SPECIFICATIONS ... 22 EDGESTAR LIMITED WARRANTY ... 23 ... 4 ... 5 ... 6 ... 7 ... 8 ... 8 ... 21...
  • Page 4: Introduction

    Introduction Thank you for purchasing this EdgeStar portable air conditioner. We are glad you chose us. We believe that your purchase of this product opens a relationship between you and EdgeStar. We will provide the customer support needed to nurture that relationship.
  • Page 5: Parts Identification

    Parts Identification Front View Control Panel Front Air Vent Handle Caster Back View Duct connector Pre-Filter Exhaust hose Air Intake Hose Drain Port Power Cord EdgeStar Portable Air Conditioner...
  • Page 6: Installing The Carbon Filter

    Activated carbon filter Installing the Carbon Filter Your portable air conditioner ships with a pre-filter and an activated carbon filter. The carbon filter will help remove contaminates and odors from the air. It is recommended you replace the carbon filter every two to three months, or as needed.
  • Page 7: Window Kit Installation Instructions

    EdgeStar Portable Air Conditioner Window Kit Installation Instructions You must vent your portable air conditioner when running in it cooling mode and heating mode (HS model). Your unit includes a window exhaust kit that can be used to vent the unit out a window.
  • Page 8: Installing The Grated Adapter

    Installing the grated adapter   1. Insert the round grated adapters through the back grooved side of the window kit plate with holes. 2. Secure the grated adapters by fastening the screws from flat side of the window kit plate to the holes on the grated adapter.
  • Page 9: Installing The Window Plates

    Please contact your EdgeStar retailer to purchase window locks. EdgeStar Portable Air Conditioner 3. Open your window and place the window kit with grooved side facing outward on the window sill. Then, slide the window kit plates to fit the width of the window. You can use screws to secure the window kit plates from sliding.
  • Page 10: Attaching The Duct Connectors To The Exhaust Hose

    Attaching the duct connectors to the exhaust hose   5. Attach the connectors to the hose: A. Extend the ends of the exhaust hose B. Thread the duct connector on by turning it clockwise until it stops. 6. Roll the unit towards the window kit. Leave a space that is at least 20 inches to the wall.
  • Page 11: Connecting The Duct Connectors To The Unit

    8. Align the slots on the duct connector to the tabs on the grated adapter and snap in place. After you have installed the exhaust hose and window kit, you can plug in your portable air conditioner and start using it.
  • Page 12 Please take this into account when deciding how to vent it. 1. The exhaust hose supplied with the portable air conditioner can be extended up to 48 inches; however for maximum efficiency, use the shortest length possible.
  • Page 13: Control Panel Overview

    EdgeStar Portable Air Conditioner Control Panel Overview Water Light WATER POWER Mode Speed Power Button Mode Button Speed Button Function Power Powers the unit on or off. Mode Changes between cool, dehumidify, fan, and heat (HS model) modes. Speed Sets the fan speed.
  • Page 14: Using The Control Panel

    Dehumidifying Mode. Using the Control Panel Use the Power button to turn the portable air conditioner on and off. By default when you first use the power button, the unit should begin to operate in cooling mode. The unit will remember the last used mode/settings if you shut down and restart.
  • Page 15: Heat Mode (Hs Model Only)

    Power button. Water Light EdgeStar Portable Air Conditioner The AP14000HS portable air conditioner can work as a heat pump. It must be vented for it to expel the cold air out the exhaust. To operate the unit in heat mode: 1) Make sure the power cord is plugged into a power outlet.
  • Page 16: Remote Control Overview

    Do not mix old and new batteries. Do not dispose of batteries in a fire as they may explode. Remote Control Overview The remote control can be used instead of the control panel to remotely operate your portable air conditioner. The remote’s functions are the same as on the control panel. Power Button Up Button...
  • Page 17: Remote Control Lcd Indicators

    NOTE: If you used the control panel to set up the unit, the remote control will not automatically update the information shown on the remote control’s LCD. EdgeStar Portable Air Conditioner Remote Control LCD Indicators Transmitter Indicator Mode Indicators Set Temperature Indicator...
  • Page 18: Operating The Remote Control

    The unit will remember the last used mode/settings if you shut down and restart. Auto-Restart: If power to the unit is interrupted, the air conditioner will restart itself in its last used mode/settings once power is restored. The compressor will restart after 3 minutes.
  • Page 19: Fan Only Mode

    Speed button to select the fan speed. You can choose between The AP14000HS model portable air conditioner can work as a heat pump. It must be vented for it to expel the cold air out the exhaust. To operate the unit in heat mode: 1) Make sure the power cord is plugged into a power outlet.
  • Page 20: Timer

    However, in very humid conditions, the internal reservoir may fill completely. This causes the air conditioner to turn off to avoid overflowing the internal reservoir. The indicator will appear on the Control Panel LCD.
  • Page 21: Energy Saving Guide

    EdgeStar Portable Air Conditioner Energy Saving Guide Read and follow the guide below to get the best performance and efficiency from your portable air conditioner:  Do not cover the air outlet (exhaust) while in use.  Do not place the unit in front of curtains or drapes- to ensure they do not obstruct the air intake.
  • Page 22: Maintenance

    Clean the air conditioner and filters regularly to maximize performance and efficiency, and prolong the unit’s life. Be sure to always unplug the air conditioner from the power outlet before cleaning. Use a soft dry cloth to wipe the body clean. If necessary, use lukewarm water to dampen a cloth to clean the unit.
  • Page 23: Troubleshooting

    EdgeStar Portable Air Conditioner Troubleshooting Follow the troubleshooting guide below to resolve common issues. Issue Possible Cause My air conditioner is Unit is not receiving not functioning at all power LCDI power cord is tripped Insufficient power Water reservoir is full...
  • Page 24: Troubleshooting Continued

    Troubleshooting continued Issue Possible Cause My air conditioner is Unit is not operating in not cooling at all cooling mode The compressor is not The ambient...
  • Page 25: Specifications

    EdgeStar Portable Air Conditioner Specifications Description of product Model Voltage/Frequency Input Power Current Color Coolant Timer Dimensions H x W x D Weight Description of product Model Voltage/Frequency Input Power Current Color Coolant Timer Dimensions H x W x D...
  • Page 26: Edgestar Limited Warranty

    EdgeStar authorized repair facility. PARTS: For a period of ONE (1) YEAR from the date of original purchase, EdgeStar will supply new, rebuilt, or refurbished parts free of charge. EdgeStar may request a defective part be returned in exchange for the replacement part.
  • Page 27 Web: http://www.edgestar.com E-mail: service@edgestar.com Register your product, download owner’s manuals, access additional troubleshooting resources, and obtain more information on other great EdgeStar products on the web at: http://www.edgestar.com Product contents and specifications may change without notice. EdgeStar Products Box 81336...