Error Messages - LOGICDATA LogicSP-2-1 User Manual

Motor control for height adjustable tv-set carriers
Table of Contents

Advertisement

User Manual
LogicSP-2-1 / LogicSP-2-2

6.2. Error Messages

The LogicSP motor control can report several error conditions to a diagnostic tool (a software
program running on a PC) or directly via a handset with integrated display.
Note: If you are not using a handset with integrated display, you will not see these error
messages.
In the absence of a handset with integrated display, these messages can be viewed
using a software program such as the LiftBox™ Diagnostic Tool by LOGICDATA.
The remainder of this section uses the appearance of these error messages on a standard
LOGICDATA handset with integrated display for illustration purposes.
The display reads HOT.
Possible Cause
The LogicSP control box is equipped with over-
temperature
protection.
mechanism forced the control box to stop.
The display reads E followed by a two-digit number.
Possible Cause
An internal error occurred.
Code
Description
00
No error.
01
Relay of motor 1 is stuck.
02
Relay of motor 2 is stuck.
06
MOSFET of motor 1 defective.
07
MOSFET of motor 2 defective.
11
Motor 1 socket shorted.
12
Motor 2 socket shorted.
16
Motor 1 socket plug detection.
17
Motor 2 socket plug detection.
21
Oscillator defective.
22
Short circuit Motorwire 1.
23
Short circuit Motorwire 2.
27
Operating Voltage too low.
28
Operating Voltage too high.
29
Impulse timeout Motor 1.
30
Impulse timeout Motor 2.
Wait until the control box has cooled down and
This
protection
the display no longer reads HOT. Then, the
control box is ready for use again.
Proceed according to the following table:
Unplug the control box. Contact our customer
service.
Unplug the control box. Contact our customer
service.
Unplug the control box. Remove the external short-
circuit. Plug-in the control box.
Connect a motor to the corresponding socket.
Unplug the control box. Contact our customer
service.
Unplug the control box. Remove external short circuit
(exchange damaged motowire). Plug-in control box.
Control box cannot function with this mains voltage.
Check specifications on the type label.
Unplug control box and contact your supplier.
Page 26 of 29
Solution
Solution
Solution