Ghost Controls TSS1 Installation And Owner's Manual

Ghost Controls TSS1 Installation And Owner's Manual

Hide thumbs Also See for TSS1:

Advertisement

TSS1 GATE OPENER INSTALLATION AND OWNERS MANUAL
A 12V BATTERY IS REQUIRED TO OPERATE OPENER AND IS NOT INCLUDED!
You must purchase a 12V Automotive or Deep Cycle Marine Battery before installing
or purchase our optional Battery Box Kit (ABBT2) for installing your operator.
WARNING: This product can expose you to chemicals including lead, which is known to the
State of California to cause cancer. For more information, go to
www.P65Warnings.ca.gov
Made in China,
©Ghost Controls
2020
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TSS1 and is the answer not in the manual?

Questions and answers

Stephen
February 23, 2025

Alarm code 5 reset Controller in open position. Piston does not move. Alarm beeps 5 times.

1 comments:
Mr. Anderson
February 23, 2025

To reset alarm code 5 (1st Arm Disconnected) on a Ghost Controls TSS1 when the controller is in the open position and the piston does not move, follow these steps:

1. Check the Arm Connection – Ensure that the first arm is properly connected to the control board.
2. Power Cycle the Control Box – Turn the control box power switch off and then back on.
3. Verify Alarm Reset – Alarm codes are only active for one minute after the gate stops moving, so after power cycling, the alarm should clear if the issue is resolved.
4. Test Gate Operation – Attempt to open or close the gate to confirm functionality.

If the problem persists, inspect wiring and connections for any damage or loose connections.

This answer is automatically generated

Lynne
April 13, 2025

Good morning. New board works great but no audible beeps when setting up remotes and no warning beeps when gate opens or closes. Is this a new feature or am I not setting something up right. Thanks

1 comments:
Mr. Anderson
April 13, 2025

There may be no audible beep when setting up remotes or when the Ghost Controls TSS1 gate opens or closes due to one or more of the following reasons:

1. The system may be disconnected from the battery, as noted in the troubleshooting steps.
2. A fuse may be blown or not properly seated, even if it tests as good.
3. The DIP switch settings may be incorrect—specifically, DIP switch #2 controls the warning beeper. If it is set to OFF, the warning beep is disabled.
4. The control board may not be receiving power, or the power indicator is not showing correct status due to lack of a solar indicator light.

Checking DIP switch #2 and ensuring proper power connection are recommended.

This answer is automatically generated

Summary of Contents for Ghost Controls TSS1

  • Page 1 TSS1 GATE OPENER INSTALLATION AND OWNERS MANUAL A 12V BATTERY IS REQUIRED TO OPERATE OPENER AND IS NOT INCLUDED! You must purchase a 12V Automotive or Deep Cycle Marine Battery before installing or purchase our optional Battery Box Kit (ABBT2) for installing your operator.
  • Page 2 C O N T A C T U S CONTACT US: 1572 Capital Circle NW, Tallahassee, FL 32303 www.ghostcontrols.com For sales, product information, or to locate a retailer near you: Call: 850-846-6400 Monday through Friday: 8:00–5:00 EST For installation assistance and technical support: Call: 850-898-1411 Monday through Friday: 8:00–5:00 EST Product information, technical article, and installation videos can be found at:...
  • Page 3: Table Of Contents

    C O N T E N T S CONTENTS Installation and Owners Manual Warranty Registration page 5 Operator Specifications page 6 System Safety page 7 System Overview page 10 Installation Planning page 12 Tools Needed page 15 Included Parts page 16 page 17 Control Box Installation page 22...
  • Page 4 Up to 1,000 ft. of wire can be used. For installations farther than 1,000 ft. from an AC power source, the Ghost Controls 10 Watt (AXDP) Solar Panel Kit can be used to charge the battery.
  • Page 5 WARRANTY REGISTER ONLINE WWW.GHOSTCONTROLS.COM NOTE If you’re unable to access the internet please fill out the warranty form below and mail in to us at Ghost Controls 1572 Capital Circle NW, Tallahassee, FL 32303 rst Name:__________________________________________ Last Name: _________________________________ Street:___________________________________________________________ Apt. #: ___________________________...
  • Page 6 S P E C I F I C A T I O N S SPECIFICATIONS TSS1 GATE OPERATOR KIT SPECIFICATIONS Compliance: The operator is system certified to be in compliance with UL325 Standard, 7th Edition System Operating Voltage: 12V DC...
  • Page 7: C O N T E N T S

    GHOST CONTROLS Technical Support for ® If you are unsure of any of these steps, please con- replacement signs if yours become damaged. tact GHOST CONTROLS Technical ® Support at 850-898-1411 or online at XII. While the gate is moving do not drive into the gate ghostcontrols.com/help/...
  • Page 8 Proper installation of these safety instructions sensors is critical to avoid false tripping while gate is in © GHOST CONTROLS 2016 motion and to reduce potential entrapment. ALARM CAUTION Extreme caution must be exercised when automatic...
  • Page 9 S Y S T E M S A F E T Y ENTRAPMENT AREA NOTES Between gate and post Keep hands, feet, and pets away from this area when gate is in motion. Pinch point between opener and gate Keep hands, feet, and pets away from this area when gate is in motion. Path of the moving gate All one zone Leading edge of gate and pinch point...
  • Page 10: System Overview

    S Y S T E M O V E R V I E W SYSTEM OVERVIEW IMPORTANT INSTRUCTIONS Thank you for choosing a GHOST CONTROLS Automatic Gate Opener system, the most innovative gate opener systems ® available for residential applications on the market today. This manual will guide you through the proper installation and main- tenance methods.
  • Page 11 S Y S T E M O V E R V I E W . When planning a system that will allow entry from a . Swing direction of gate(s). The image (shown in dia- busy road or highway, make sure the system is placed gram below) indicates the more common “Pull-to- Open”...
  • Page 12: Installation Planning

    P L A N N I N G INSTALLATION PLANNING SITE PLANNING SITE INSTALLATION VIDEO CAN BE FOUND AT GhostControls.com/Support/Installation-Video PREPARE THE GATE Proper installation, care, and ongoing maintenance of the gate is critical to increased usage life of the automatic gate opera- tor system.
  • Page 13 P L A N N I N G NOTE Push-to-Open installations REQUIRE an accessory Push-to-Open bracket kit (AXPO). Mounting location on gate and support post, column, or wall. A. Wooden posts should be at least 6 x6 in size and set in concrete. B.
  • Page 14 flexing of the gate while in motion. OPERATOR REAR MOUNT INSTALLATION CONSIDERATIONS The GHOST CONTROLS Automatic Gate Operator system is designed for installation on rectangular, square, or round ® AX3R AND AX4R ROUND POST ADAPTER ACCESSORIES) or posts (for 3"...
  • Page 15: Tools Needed

    T O O L S N E E D E D TOOLS NEEDED Corded/Cordless Drill 5/16" Drill Bit Standard or 7/32" Drill Bit Metric Wrenches Metr 7/16" Drill Bit (longer than diameter or thickness of post) Clamp Wire Strippers/Cutters trippers/Cutters trippers/Cutters trippers/Cutters trippers/Cutters...
  • Page 16: Included Parts

    Gate Mounting Hardware: Front Mounting Hardware: Rear Mounting Hardware: Control Box Control Box Mounting: AC Transformer in TSS1 Kit: 1st Opener Arm: 3 Button Remote: 10W Solar Panel TSS1XP Kit: © G h o s t C o n t r o l s 2 0 2 0 ®...
  • Page 17 Operator is not for use on solid panel privacy gates. The dimensions and step-by-step instructions that follow are for mounting the GHOST CONTROLS Gate Operator in ® installation system to a standard metal tubular-style agricultural gate that swings into property.
  • Page 18 STEP 2. Post bracket pre-assembly. Insert the M10x1.5x75mm bolt and M10 washer through the hole that is closest to the post on the post bracket. Bolt should then go through first pivot bracket, pivot spacer, second pivot bracket, and exit bottom hole of post bracket as shown below. Fasten a M10 washer and M10 locknut on the end of the bolt.
  • Page 19 NOTE For round wooden post installations we recommend notching the wooden post for proper installation of the post bracket. Follow the diagram for proper notching of a round post. 4-3/8" Width (4" minimum) 4.5" Height NOTE AX3R AND AX4R round post adapter accessories (sold separately). See illustration using the round post adapter below.
  • Page 20 STEP 4. Verifying minimum of 4˝ Gate Clearance and finishing rear post mount bracket assembly. If the clearance is less than 4˝, you will need to adjust the pivot brackets so that you have at least 4˝ of clearance. Once the clearances are correct, place the secondary bolt into the pivot bracket as shown. Insert the M10x1.5x75mm bolt and M10 washer through the post bracket hole, then first pivot bracket, pivot spacer, second pivot bracket, and exit out bottom hole of post bracket as shown below.
  • Page 21 STEP 5. Drilling rear post bracket holes and bolting. A . With the post bracket still clamped to post, mark the center of the bracket slots. Remove the bracket. You will need a 7/16˝ drill bit to drill the (4) holes to mount the rear post bracket to the post. TIP: Drill each hole one at a time and insert a bolt through to ensure that the holes are large enough and all aligned.
  • Page 22 OPEN SYSTEM STEP 7. Determine the mounting location of the control box and install. NOTE Mount the control box a minimum of 3 feet above the ground to keep dirt and water from damaging the control board and within 4 feet of the operator arm in order for the operator cable to reach the control box. A .
  • Page 23 Strain Relief B. Connect the terminal leads of the battery harness to your battery. IMPORTANT YOU NEED A 12V DEEP CYCLE MARINE/AUTOMOTIVE BATTERY OR THE ABBT2 BATTERY BOX KIT WITH TWO BATTERIES. SYSTEM WILL NOT OPERATE WITHOUT A BATTERY INSTALLED AND CONNECTED AT ALL TIMES.
  • Page 24: Connecting Arm To Control Box

    CONNECTING OPERATOR ARM TO CONTROL BOX STEP 9. Insert the operator cable into the control box. A . Route the operator cable through the same strain relief as the battery harness cable and into the control box. B. Connect the operator wires to the control board. Find the 1st operator screw terminal on control board and insert the red, black, green and white wires (left to right) into the matching color coded terminals and tighten each of the screws so that...
  • Page 25 PREPARING THE GATE SYSTEM CONTROLLER The gate system control board provides one convenient place to make all of your system connections and to change any settings that you desire to personalize how your automatic gate opener system operates at your home or property. This main board (shown below) is located inside of the control box of your system and will be referred to in detail through the next few sections.
  • Page 26 DIP Switch # OFF Position (FACTORY SETTING) ON Position Patent-pending SafeForce® Mode Monitored Safety Mode: Monitored safety devices required / (Factory Default): Force output is Compatible GHOST CONTROLS safety devices only. ® limited to ensure safe operation as Monitored safety devices must be present and operate prop- specified by Type C in UL325...
  • Page 27 TURN CONTROL BOX ON. YOU SHOULD HEAR A SERIES OF BEEPS AS THE SYSTEM IS TURNED ON. STEP 11. Locate the jog buttons at the top right of the control box to test the arm function. ARM EXTENDED OUT 3-4 INCHES WARNING: Step 12 needs to be completed.
  • Page 28 TURN THE CONTROL BOX OFF STEP 13A. FOR TUBE GATES ONLY attach the front mount using the tube gate brackets. A . Before assembling gate bracket make sure the (2) tube clamp brackets fit over the tubular gate bar. If not they will need to be flared before continuing on to next step.
  • Page 29 STEP 14A. FOR TUBE GATES, attach the tube gate bracket to the gate. The gate must remain in the desired open position. OPEN THE GATE TO THE DESIRED OPEN POSITION A . Attach the gate bracket assembly to the fully retracted operator as shown. Insert the supplied 10mm x 40 mm clevis pin, 10mm I.D Nylon Spacer, and clevis hairpin through the front of the operator and gate bracket to secure the bracket onto the front mount of the gate operator.
  • Page 30 STEP 14B. FOR FLAT PANEL GATES, gate must remain in the desired open position when attaching the front mount to the gate. OPEN THE GATE TO THE DESIRED OPEN POSITION A . Line up the pre-assembled front mount gate bracket over the center-most bar on your gate and mark the center location of the outermost hole on the gate.
  • Page 31 B. Install the front mount gate bracket on the gate by aligning the outermost hole and inserting (1) M8 x 65mm flat washer, and (1) M8 nylon locknut through gate and front mount bracket, as show below. Tighten to secure the brackets to the gate.
  • Page 32 F. Align the innermost hole of the gate bracket and insert (1) M8 x 65mm flat washer, and (1) M8 nylon locknut through both holes and tighten to secure the bracket to the gate. YOUR FRONT MOUNT GATE BRACKET SHOULD NOW BE ATTACHED AND SECURED TO THE GATE. G.
  • Page 33 This is the most common installation. The CLOSED limit is when the operator is extended and the gate is in the closed position. IMPORTANT ONLY THE OPERATOR ARMS’ EXTENDED LIMIT IS ADJUSTABLE AND CAN BE SET WITH THE CONTROL BOARD. THE ARMS’ RETRACTED POSITION IS FIXED AND IS NOT ELECTRONICALLY ADJUSTABLE. THE OPEN POSITION IS SET BY HARDWARE MOUNTING ONLY.
  • Page 34 POWERING THE SYSTEM WITH THE AC TRANSFORMER NOTE DO NOT USE THE AC TRANSFORMER AND SOLAR POWER AT THE SAME TIME! NOTE STEP 18. Route the AC transformer cable into the control box. (See note above) A . When wiring the AC Transformer you will need to insert the AC wires in the MATCHING CENTER AND RIGHT TERMINALS on the PWR INPUT screw terminals on the main control board and tighten each screw so that the wires do not come loose and fall out.
  • Page 35 C. Check the chart shown for number of hours of direct sunlight available for solar applications. D. Determine the number of expected winter cycles for a single gate using solar power by reviewing the map and chart shown. SHOULD BE CONNECTED TO ANY GHOST CONTROLS SYSTEM CONTROL BOARD. E CONNECTED TO ANY GHOST CONTROLS SYSTE...
  • Page 36 SETTING AUTOCLOSE TIME ON YOUR GATE The AUTOCLOSE TIME setting determines how long the gate will remain open each time it operates before automatically closing. The which requires the user to push either a remote transmitter button, keypad code, or push-button to close the gate.
  • Page 37 CANCELLING AUTOCLOSE TIME ON YOUR GATE NOTE Canceling AUTOCLOSE can only be performed when the gate opener is idle. Cancelling AUTOCLOSE will remove your previous duration setting and force you to pick a new duration the next time you enable AUTOCLOSE. You can use PartyMode to temporarily disable AUTOCLOSE and the system will retain your ®...
  • Page 38 Operator is not for use on solid panel privacy gates. The dimensions and step-by-step instructions that follow are for mounting the GHOST CONTROLS Gate Operator ® PUSH-TO-OPEN installation system to a standard metal tubular-style agricultural gate that swings into property. You will need to make sure you purchase the Push-To-Open Bracket Kit (AXPO) before you start installing.
  • Page 39 STEP 2. Post bracket pre-assembly. YOU START THIS STEP Insert the M10x1.5x75mm bolt and M10 washer through the hole that is closest to the post on the post bracket. Bolt should then go through first push-to-open bracket, pivot spacer, second push-to-open bracket, and exit bottom hole of post bracket as shown.
  • Page 40 NOTE For round wooden post installations we recommend notching the wooden post for proper installation of the post bracket. Follow the diagram below for proper notching of a round post. 4-3/8" Width (4" minimum) 4.5" Height NOTE AX3R AND AX4R round post adapter accessories (sold separately). See illustration using the round post adapter below.
  • Page 41 STEP 4. Verifying minimum of 4˝ gate clearance and finishing rear post mount bracket assembly. If the clearance is less than 4˝, you will need to adjust the pivot brackets so that you have at least 4˝ of clearance. Once the clearances are correct, place the secondary bolt into the post bracket as shown. Insert the M10x1.5x 75mm bolt and M10 washer through the post bracket hole, then first push-to-open bracket, pivot spacer, second push-to-open bracket, and exit out bottom hole of post bracket as shown below.
  • Page 42 STEP 5. Drilling rear post bracket holes and bolting. STEP 5. Drilling rear post bracket holes and bolting. A . With the post bracket still clamped to post, mark the center of the bracket slots. Remove the bracket. A . With the post bracket still clamped to post, mark the center of the bracket slots. Remove the bracket. You will need a 7/16˝...
  • Page 43 OPEN SYSTEM STEP 7. Determine the mounting location of the control box and install. NOTE Mount the control box a minimum of 3 feet above the ground to keep dirt and water from damaging the control board and within 4 feet of the operator arm in order for the operator cable to reach the control box. A .
  • Page 44 CONNECTING AND INSTALLING THE BATTERY AND BATTERY HARNESS STEP 8. Insert battery harness through strain relief in control box and attach to the control board. A . Route the battery harness cable through the strain relief on the bottom of the control box and connect the bullet connectors (red to red, black to black) to the control board harness.
  • Page 45 CONNECTING OPERATOR ARM TO CONTROL BOX STEP 9. Insert the operator cable into the control box. A . Route the operator cable through the same strain relief as the battery harness cable and into the control box. B. Connect the operator wires to the control board. Find the 1st operator screw terminal on control board and insert the red, black, green and white wires (left to right) into the matching color coded terminals and...
  • Page 46 PREPARING THE GATE SYSTEM CONTROLLER The gate system control board provides one convenient place to make all of your system connections and to change any settings that you desire to personalize how your automatic gate opener system operates at your home or property. This main board (shown below) is located inside of the control box of your system and will be referred to in detail through the next few sections.
  • Page 47 DIP Switch # OFF Position (FACTORY SETTING) ON Position Patent-pending SafeForce® Mode Monitored Safety Mode: Monitored safety devices required / (Factory Default): Force output Compatible GHOST CONTROLS safety devices only. ® is limited to ensure safe opera- Monitored safety devices must be present and operate prop- tion as specified by Type C in UL325...
  • Page 48 TURN CONTROL BOX ON. YOU SHOULD HEAR A SERIES OF BEEPS AS THE SYSTEM IS TURNED ON. STEP 11. Locate the jog buttons at the top right of control box to test the arm. ARM EXTENDED OUT 3-4 INCHES WARNING: Step 12 needs to be completed.
  • Page 49 TURN THE CONTROL BOX OFF STEP 13A. FOR TUBE GATES ONLY attach the front mount using the tube gate brackets. A . Before assembling gate bracket make sure the (2) tube clamp brackets fit over the tubular gate bar. If not they will need to be flared before continuing on to next step.
  • Page 50 P U S H - T O - O P E N STEP 14A. FOR TUBE GATES attach the tube gate bracket to the gate. The gate must remain in the desired closed position. CLOSE THE GATE TO THE DESIRED CLOSED POSITION A .
  • Page 51 STEP 14B. FOR FLAT PANEL GATES attach the front mount bracket to the gate. The gate must remain in the desired closed position. CLOSE THE GATE TO THE DESIRED CLOSED POSITION A . Line up the pre-assembled front mount gate bracket over the center-most bar on your gate and mark the center location of the outermost hole on the gate.
  • Page 52 B. Install the front mount gate bracket on the gate by aligning the outermost hole and inserting (1) M8 x 65mm flat washer, and (1) M8 nylon locknut through gate and front mount bracket, as show below. Tighten to secure the brackets to the gate.
  • Page 53 F. Align the innermost hole of the gate bracket and insert (1) M8 x 65mm flat washer, and (1) M8 nylon locknut through both holes and tighten to secure the bracket to the gate. YOUR FRONT MOUNT GATE BRACKET SHOULD NOW BE ATTACHED AND SECURED TO THE GATE. G.
  • Page 54 The OPEN limit is when the operator is extended and the gate is in the closed position. IMPORTANT ONLY THE OPERATOR ARMS’ EXTENDED LIMIT IS ADJUSTABLE AND CAN BE SET WITH THE CONTROL BOARD. THE ARMS’ RETRACTED POSITION IS FIXED AND IS NOT ELECTRONICALLY ADJUSTABLE. THE CLOSED POSITION IS SET BY HARDWARE MOUNTING ONLY.
  • Page 55 POWERING THE SYSTEM WITH THE AC TRANSFORMER NOTE DO NOT USE THE AC TRANSFORMER AND SOLAR POWER AT THE SAME TIME! NOTE STEP 18. Route the AC transformer cable into the control box. A . When wiring the AC Transformer you will need to insert the AC wires in the MATCHING CENTER AND RIGHT TERMINALS on the PWR INPUT screw terminals on the main control board and tighten each screw so that the wires do not come loose and fall out.
  • Page 56 D. Determine the number of expected winter cycles for a single gate using solar power by reviewing the map and chart shown. SHOULD BE CONNECTED TO ANY GHOST CONTROLS SYSTEM CONTROL BOARD. © G h o s t C o n t r o l s 2 0 2 0 ®...
  • Page 57 SETTING AUTOCLOSE TIME ON YOUR GATE The AUTOCLOSE TIME setting determines how long the gate will remain open each time it operates before automatically closing. The which requires the user to push either a remote transmitter button, keypad code, or push-button to close the gate.
  • Page 58 CANCELLING AUTOCLOSE TIME ON YOUR GATE NOTE Canceling AUTOCLOSE can only be performed when the gate opener is idle. Cancelling AUTOCLOSE will remove your previous duration setting and force you to pick a new duration the next time you enable AUTOCLOSE. You can use PartyMode to temporarily disable AUTOCLOSE and the system will retain your ®...
  • Page 59: Setting The Closed Limit

    T R O U B L E S H O O T I N G TROUBLESHOOTING GUIDE FOR HELPFUL VIDEOS VISIT: FOR MORE TROUBLESHOOTING TIPS VISIT: LEARN NEW REMOTE 2018-08 DO NOT USE this procedure if you already have a remote that operates the gate and just want to add an additional remote. If you want to add an additional remote, please refer to the remote manual for adding additional remote for your system.
  • Page 60 CONNECTING TO CONTROL BOARD NOTE Please refer to the manufacturer’s manual or website for more detailed instructions on how to connect and use accessories from other manufacturer’s with your Ghost Controls gate opener. ® PREPARING CONTROL BOX FOR ACCESSORY WIRING...
  • Page 61 INACTIVE — Opens circuit or has no connection. ACTIVE — Input is shorted to COM or BATTERY NEGATIVE. Use this terminal for Ghost Controls Push Button (AXPB). Active — Signal must go from INACTIVE then ACTIVE for the system to recognize the input and respond accordingly.EX: OPEN >...
  • Page 62: Manual Gate Operation

    M A N U A L MANUAL GATE OPERATION EVERY USER MUST KNOW THESE STEPS The gate can be opened or closed manually by releasing the front mount from the gate. You must disconnect the operator only after the operator power switch is OFF and the gate is NOT moving. If you have the accessory ZombieLock installed, this lock should be manually disengaged with the key because removing power does not ®...
  • Page 63: Accessories

    , determine gate opener system battery status, and can be quickly added as ® a new remote to an existing system. CR2032 Battery Included. The standard remote transmitter will control up to two separate GHOST CONTROLS gate systems ® (single or dual) and it can be learned as a new remote to an existing system. CR2032 Battery Included.
  • Page 64 ZombieLock , or any other device that needs to be attached to tubes. ® The GHOST CONTROLS Vehicle Sensor is the easiest way to trigger your gate to open when a vehicle ® is trying to exit your property. This sensor is buried beneath the ground surface next to your driveway and connects into your gate controller box.