THD (Total Harmonic Distorsion) <3% • Protections: undervoltage, overvoltage, overheating, overload, short circuit Introduction SP series PNI inverters convert 12V DC input voltage into 230V AC 50Hz voltage. We recommend that you read this manual carefully before putting the product into operation. Warnings •...
Safety precaution We recommend that you read this chapter carefully before using the product, in order to avoid personal injury and product damage. Symbols description Safety sign Antistatic sign Danger, electric shock The inverter generates high temperatures during usage. Carefully read the installation and operating instructions to avoid personal injury or damage to the equipment.
Page 5
4. Keep the inverter packaged before installation and use. 5. Do not manipulate the inverter in the presence of electrical conductors: metal watch, bracelets, rings. 6. The inverter must be repaired, installed and maintained only by qualified personnel. Inductive load and half-wave rectification load attentions! We recommend choosing an inverter with a power 2-3 times higher than the half-wave rectification or inductive load.
not blocked in any way. Also, do not mount the passive radiator part of the housing attached to a wall, ceiling or floor, but at a distance that allows air to pass. Inverter installation Enviroment conditions Keep the inverter in a dry and ventilated environment. Keep the inverter away from moisture, dust, heat, sunlight, volatile gas or high salinity.
Page 7
4. Connect the load to the Schuko socket. 5. After making sure all connections are made correctly, turn on the inverter. If the green LED indicator lights up, it means that the output voltage is correct and the inverter is working properly. The correct connection of the inverter is shown in the following diagram.
Maximum discharge current = Rated power / (storage voltagex0.85) Battery storage capacity = average discharge current discharge time Example: PNI SP1000W has a rated power of 1000W, 12V input voltage: Average discharge current = 1000 / (12x0.85) = 98A If kept on for 2 hours:...
Page 9
Choose a battery with a capacity greater than 196 Ah. Recommended values for the batteries Invertor Power (W) Recommended battery SP500W 12V, ≥100Ah SP1000W 1000 12V, ≥150Ah SP2000W 2000 12V, ≥200Ah User manual...
Troubleshooting The inverter does not 1. The battery is defective 1. Replace the battery turn on and the Power 2. The battery 2. Connect the battery LED does not light up connection is abnormal carefully 3. The fuse is blown 3.
Page 11
The inverter does not 1. The wires between the 1. Shorten the threads or work at 100% load battery and the inverter use thicker threads. We are too long. recommend using the 2. The connection to the wires in the package. battery / inverter is weak.
Technical specifications SP500W SP1000W SP2000W Input voltage 12V DC Output power 500W 1000W 2000W Output voltage 230V AC Frequency 50Hz/60Hz Transfer efficiency >88% Output wave Pure sine wave Total harmonic THDV ≤3% (100% linear load) distortion Overload capacity >120% undervoltage, overvoltage, overheating, overload,...
Page 13
• Protectie la subtensiune, supratensiune, supraincalzire, suprasarcina, scurtcircuit Introducere Invertoarele PNI din seria SP transforma tensiunea de intrare 12V DC in 230V AC 50Hz. Va recomandam sa cititi cu atentie acest manual inainte de punerea in functiune a produsului. Atentionari •...
Masuri de siguranta Va recomandam sa cititi cu atentie acest capitol inainte de utilizarea produsului, pentru a evita accidentarea personala si defectarea produsului Descriere simboluri Semn de siguranta Semn antistatic Pericol de electrocutare Invertorul genereaza temperaturi inalte in timpul functionarii. Cititi cu atentie instructiunile de montaj si utilizare, pentru e evita ranirea personala sau deteriorarea echipamentului.
Page 15
va asigura ca sistemul este descarcat complet. 4. Pastrati invertorul impachetat inainte de instalare si utilizare. 5. Nu manipulati invertorul in prezenta unor conductori electrici: ceas metalic, bratari, inele. 6. Invertorul trebuie fixat, instalat si intretinut doar de personal calificat. Atentie la sarcinile inductive si la rectificari de jumatate de unda Va recomandam sa alegeti un invertor cu o putere de 2-3 ori mai mare decat puterea consumatorilor de tip inductiv sau jumatate de unda modificata.
Page 16
a carcasei lipita de un perete, tavan sau podea, ci la o distanta ce permite trecerea aerului. Instalarea invertorului Conditii mediu de instalare Pastrati invertorul in mediu uscat si ventilat. Pastrati invertorul departe de umezeala, praf, caldura, lumina soarelui, gaz volatil sau cu salinitate ridicata. Precautii Intervalul de temperatura de functionare a produsului este -26˚C ~ + 60˚C .
Page 17
5. Dupa ce va asigurati ca toate conexiunile sunt facute corect, porniti invertorul. Daca indicatorul LED verde se aprinde, inseamna ca tensiunea de iesire este corecta si invertorul functioneaza corect. Conectarea corecta a invertorului este prezentata in urmatoarea schema. Atentionari 1.
Page 18
Curent maxim de descarcare = Putere nominala/(tensiune stocarex0.85) Capacitate de stocare baterie = curent mediu de descarcarextimp de descarcare Exemplu: PNI SP1000W are o putere nominala de 1000W, tensiune de intrare 12V, deci: Curent mediu de descarcare = 1000/(12x0.85)= 98A Daca se mentine 2 ore pornit:...
Page 19
Capacitate de stocare baterie = 98x2=196 Ah Alegeti o baterie cu o capacitate mai mare de 196 Ah. Valori recomandate pentru baterie Invertor Putere (W) Baterie recomandata SP500W 12V, ≥100Ah SP1000W 1000 12V, ≥150Ah SP2000W 2000 12V, ≥200Ah Manual de utilizare...
Page 20
Probleme si solutii Invertorul nu 1. Bateria este defecta 1. Schimbati bateria porneste si LED-ul 2. Conexiunea la baterie 2. Conectati bateria cu Power nu se aprinde este anormala grija 3. Siguranta este arsa 3. Schimbati siguranta Invertorul este in Invertorul este in 1.
Page 21
Invertorul nu 1. Firele intre baterie si 1. Scurtati firele sau functioneaza in sarcina invertor sunt prea lungi. folositi fire mai groase. 100% 2. Conectarea la baterie / Recomandam utilizarea invertor este slabita. firelor din colet. 2. Verificati si strangeti conectorii pe invertor si baterie.
Specificatii tehnice SP500W SP1000W SP2000W Tensiune de intrare 12V DC Putere de iesire 500W 1000W 2000W Tensiune de iesire 230V AC Frecventa 50Hz/60Hz Eficienta de transfer >88% Unda de iesire Sinusoida pura Distorsiune THDV ≤3% (100% linear load) armonica totala Capacitate >120%...
Page 23
Declaración UE de conformidad simplificada SC ONLINESHOP SRL declara que el Inversor de energia PNI SP500W, SP1000W, SP2000W cumple con la Directiva EMC 2014/30/EU. El texto completo de la declaración de conformidad de la UE está disponible en la siguiente dirección de Internet: https://www.mypni.eu/products/6848/download/certifications...
Need help?
Do you have a question about the SP500W and is the answer not in the manual?
Questions and answers