Wenglor CP08MHT80 Operating Instructions Manual

High-performance distance sensor

Advertisement

EN
CP08MHT80 OCP801H0180
CP24MHT80 OCP162H0180
CP35MHT80 OCP352H0180
High-Performance Distance Sensor
Operating Instructions
Translation of the Original Operating Instruction
Subject to change without notice
Available as PDF version only
Status: 24.03.2021
www.wenglor.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CP08MHT80 and is the answer not in the manual?

Questions and answers

Summary of Contents for Wenglor CP08MHT80

  • Page 1 CP08MHT80 OCP801H0180 CP24MHT80 OCP162H0180 CP35MHT80 OCP352H0180 High-Performance Distance Sensor Operating Instructions Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Status: 24.03.2021 www.wenglor.com...
  • Page 2 Index Proper Use Safety Precautions 2.1. Safety Precautions 2.2. Laser/LED warning 2.3. Approvals and IP Protection Technical Data 3.1. Complementary Products (see catalog) 3.2. Connection Diagram 3.3. Housing Dimensions 3.4. Control Panel Installation Instructions Initial Operation Function Adjustment 7.1. Manual Adjustments 7.2.
  • Page 3: Proper Use

    1. Proper Use High performance distance sensors which use the principle of angle measurement determine the distance be- tween the sensor and the object. These sensors have small working ranges (under 1 m) and recognize objects with high precision. Some sensors use a high-resolution CMOS line array and DSP signal processing. The color, shape and texture of the objects to be recognized does not affect the sensors’...
  • Page 4 2.3. Approvals and IP Protection RoHS Safety Precautions...
  • Page 5: Technical Data

    3. Technical Data CP08MHT80 CP24MHT80 CP35MHT80 Optical Data Working Range 30…80 mm 40...160 mm 50...350 mm Measuring Range 50 mm 120 mm 300 mm Resolution < 8 µm < 20 µm < 50 µm Resolution (Speed-Mode) < 12 µm < 30 µm <...
  • Page 6 OCP801H0180 OCP162H0180 OCP352H0180 Optical Data Working Range 30…80 mm 40...160 mm 50...350 mm Measuring Range 50 mm 120 mm 300 mm Resolution < 8 µm < 20 µm < 50 µm Resolution (Speed-Mode) < 12 µm < 30 µm < 80 µm Linearity 0,1 % 0,1 %...
  • Page 7: Connection Diagram

    3.1. Complementary Products (see catalog) wenglor offers Connection Technology for field wiring. Suiting Connection Technology No. Suiting Mounting Technology No. Analog Evaluation Unit AW02 Feldbus Gateways ZAGxxxN01 Interface Cable S232W3 Protection Housing Set ZSP-NN-02 Protection Housing ZSV-0x-01 3.2. Connection Diagram...
  • Page 8: Installation Instructions

    3.4. Control Panel On the control panel you find the Plus key and the Minus key, several LEDs and the rotary selector switch. The rotary selector switch is used for choosing the setting- and operation functions.  = Minus key (with LED) ...
  • Page 9: Manual Adjustments

    Outputs Analogue Output The analogue output is connected to analogue earth. The analogue output can be configured as a current output or a voltage output. If you have the choice we recommend the use of the voltage output (reduced cur- rent consumption).
  • Page 10 Set Input The Input can be used as RS-232 Receive Line (RxD), Emitted Light can be switched off at 24 V (La) or Emitted Light can be switched off at 0 V (La) . • Rotary Selector Switch Ý to RxD/La Mode è...
  • Page 11 Operate the sensor with high speed (Speed-Mode) • Set the rotary selector switch Ý to RES. / SPEED-MODE è The red F-LED lights up è The yellow U-LED lights up: Sensor presently set to high speed è The yellow I-LED lights up: Sensor presently set to high Resolution •...
  • Page 12: Special Settings

    7.2. Special Settings Adjusting the filter function: • Set the rotary selector switch Ý to FILTER ADJUST è The red F-LED lights up è The yellow LEDs are off: Filter function is presently disabled è Yellow LEDs blink once followed by a pause: filter currently set to level 1 (1/4 cut-off frequency) è...
  • Page 13 (connection 3, green) and can be connected to the appropriate connections of the communication partner. Software Tools: Software for the interface of the CP08 is available. Download address: www.wenglor.com Interface configuration: Baud rate: 38.400 baud, 8 data bits, no parity, 1 stop bit...
  • Page 14 Protocol for Communications via the RS-232 Interface Frame Layout for Data Transmission Transmitting Partner Characters (ASCII) Receiving Partner Frame Segment Start character / (ASCII 47) => Connect Frame header Length information 2 Byte => Connect Frame header Command bytes 2 Byte =>...
  • Page 15: Sensor Settings

    Adjustments about RS-232 Interface In the following commands is: = place holder for entered and emitted values = place holder for the Checksum Sensor Settings Reset Function Send Frame to the Response Frame from Sensor the Sensor Reset /000R4D. /030R0127D. Configure Output Function Send Frame to the...
  • Page 16 Function Send Frame to the Response Frame from Sensor the Sensor Teach-In measuring range initial point (0 V, 4 mA) /020T024B. /030MTx2qq. x = 0: Teach-In measuring range: both points acquired x = 1: Teach-In measuring range: one point still required Function Send Frame to the Response Frame from...
  • Page 17 Set Delay Time of Contamination Output Function Send Frame to the Response Frame from Sensor the Sensor Set Delay Time of Contamination Output /030fgxxqq. /030fgxxqq. xx = 00...99 for 1 to 99 measurements until the Error Output reacts in case of errors. The default value is 20. Attention: The duration of cycles of the number of measurements depends on the exposure time, but the delay time cannot be allocated.
  • Page 18 Function Send Frame to the Response Frame from Sensor the Sensor Query sensor status for Output, Teach Mode, /000W48. /050Wgtffeqq. Filter level and Error status output status for voltage output output status for current output teach mode zero point teach mode measuring range: one point still required teach mode measuring range: both points still acquired Filter adjustment error status: no errors...
  • Page 19: Maintenance Instructions

    Respectively valid national waste disposal regulations apply to product disposal. 10. EU Declaration of Conformity The EU declaration of conformity can be found on our website at www.wenglor.com in download area. High-Performance Distance Sensor...

This manual is also suitable for:

Ocp801h0180Cp24mht80Ocp162h0180Cp35mht80Ocp352h0180

Table of Contents