NI PXI-1422 Getting Started

Image acquisition device for pxi, pci, or compactpci

Advertisement

Quick Links

Getting Started with the NI PXI/PCI-1422
The NI PXI/PCI-1422 (NI 1422) is an image acquisition device for PXI, PCI, or CompactPCI. This
document describes how to install and configure the necessary hardware and software components
to begin using the NI 1422.
What You Need to Get Started
You need the following items to set up and use the NI 1422:
NI 1422 image acquisition device
Video camera or other video device
D100 series camera cables, depending on your camera
PXI, PCI, or CompactPCI computer running Microsoft Windows Vista/XP/2000 with at least one
available slot
Note
Visit
Instruments image acquisition device compatibility with Windows Vista.
NI Vision Acquisition Software 8.0 or later, which includes the NI-IMAQ driver software
Optional software for developing applications:
NI Vision Builder for Automated Inspection
NI Vision Development Module
LabVIEW
LabWindows
Microsoft Visual Basic
Optional Equipment
National Instruments offers a variety of products for use with your NI 1422, including the following:
D2504 video cable for access to trigger lines
Four-pod BNC cable that routes trigger signals to a BNC connector block
RTSI bus cables for connecting the NI 1422 to other Vision, Motion Control, or Data Acquisition
(DAQ) devices
Refer to the National Instruments catalog, visit
you for more specific information about these products.
Related Documentation
The following documents contain additional information that you may find helpful:
NI PXI/PCI-1422 User Manual—Contains information about programming options, hardware
functionality, and signal connections.
NI Vision Acquisition Software Release Notes—Contains information about new functionality,
minimum system requirements, and installation instructions for the NI-IMAQ driver software.
and enter
ni.com/info
/CVI
for more information about National
rdvisionvista
, or call the National Instruments office nearest
ni.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PXI-1422 and is the answer not in the manual?

Questions and answers

Summary of Contents for NI PXI-1422

  • Page 1 Getting Started with the NI PXI/PCI-1422 The NI PXI/PCI-1422 (NI 1422) is an image acquisition device for PXI, PCI, or CompactPCI. This document describes how to install and configure the necessary hardware and software components to begin using the NI 1422.
  • Page 2: Safety Information

    • Measurement & Automation Explorer Help for NI-IMAQ—Describes how to configure the NI-IMAQ driver software, NI image acquisition devices, and cameras using Measurement & Automation Explorer (MAX). • NI-IMAQ Help—Contains fundamental programming concepts for the NI-IMAQ driver software and terminology for using NI image acquisition devices.
  • Page 3: Installation

    Unpacking The NI 1422 ships in an antistatic package to prevent electrostatic discharge from damaging device components. To avoid such damage in handling your device, take the following precautions: Ground yourself using a grounding strap or by touching a grounded object, such as the computer chassis.
  • Page 4 NI PXI-1422 You can install an NI PXI-1422 in any available 5 V peripheral slot in a PXI or CompactPCI chassis. Install the NI Vision Acquisition Software before installing the NI PXI-1422. Refer to the NI Vision Acquisition Software Release Notes for specific installation instructions.
  • Page 5: Specifications

    The NI PCI-1422 is now installed and the camera is connected. Configuring the NI 1422 After you have installed the NI 1422 and powered on the computer, the computer will recognize the device and assign resources to it. Use Measurement & Automation Explorer (MAX), the National Instruments configuration utility, to configure the NI 1422 for acquisition.
  • Page 6: Pci Interface

    –12 V (20 mA) Physical Dimensions PCI-1422 ............10.7 × 17.5 cm (4.2 × 6.9 in.) PXI-1422............16 × 10 cm (6.3 × 3.0 in.) Weight PCI-1422............0.127 kg (0.28 lb) PXI-1422............0.172 kg (0.38 lb) Environment Operating temperature ........... 0 °C to 55 °C Storage temperature ..........–20 °C to 70 °C...
  • Page 7: Electromagnetic Compatibility

    Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification search by model number or product line, and click the appropriate link in the Certification column. © National Instruments Corporation Getting Started with the NI PXI/PCI-1422...
  • Page 8: Waste Electrical And Electronic Equipment (Weee)

    Thailand 662 278 6777, Turkey 90 212 279 3031, United Kingdom 44 (0) 1635 523545 National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies.

This manual is also suitable for:

Pci-1422

Table of Contents