Whirlpool 8LIECHK-SSF-WL User Manual page 12

Hot, room & cold temperature water cooler
Table of Contents

Advertisement

Step B: Sanitize Probe and Taps
1. In a clean container, make a sanitizing solution of 1.5 gallons of tap water and 1.5 tablespoons
of unscented household bleach composition(I.E.5.25% sodium hypochlorite).
2. Wipe the probe and the area around all the taps with a soft cloth moistened with the sanitizing
solution.
Step C: Sanitize Reservoirs
1. Remove the cap from a spare empty 5 gallon bottle.
2. Fill the bottle with the water and bleach mixture.
3. Insert the probe into the bottle .
WARNING
Electrical shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
serious injury, fire, or electrical shock.
4. Slide the bottle into the cabinet and close the door.
5. Plug the power cord into a grounded wall outlet.
6. Turn the energy saving switches ON.
7. Allow the water and bleach mixture to fill up the empty reservoirs.
8. Wait 10 minutes then turn the energy saving switches OFF and unplug the power cord.
9. Dispense 1 cup of the water/bleach solution through each tap to clean out the waterways.
10. Place a 2 gallon or larger bucket under the drain plug in the rear of the dispenser.
11. Remove the drain cap and the drain plug. Cold water will immediately flow into the bucket. After
several seconds, hot water will dispense.
Reminder - Place the drain cap and the drain plug in a safe location so that they will not be
lost.
12. Once the unit has been drained, replace the drain plug and the drain cap.
13. Remove the remaining water from the reservoir by dispensing from the cold tap into a pitcher.
IMPORTANT: Do NOT Return Dispenser To Store.
If you have a question or problem, please contact 1-855-594-4755 for assistance.