25L and 50L Electric Storage Water Heater
Models:
25S124P, 25S136, N25S124P,
N25S136, 50S124P, 50S136,
N50S124P, N50S136
Installation Details
Owner's Information
Warranty
For advice, repairs and service, call:
1300 365 115 (Australia)
0800 729 389 (New Zealand)
Carefully remove all packaging and
transit protection from the heater before
installation. Dispose of the packaging
responsibly using re-cycling facilities
where they exist.
Specifications and materials may change without notice.
Effective for the above model numbers of electric storage water heaters manufactured and
sold after 1st March 2021.
028299
Rev. C

Advertisement

loading
Need help?

Need help?

Do you have a question about the proflo 25S124P and is the answer not in the manual?

Questions and answers

Summary of Contents for Dux proflo 25S124P

  • Page 1 Owner’s Manual 25L and 50L Electric Storage Water Heater Models: 25S124P, 25S136, N25S124P, N25S136, 50S124P, 50S136, N50S124P, N50S136 Installation Details Owner’s Information Warranty For advice, repairs and service, call: 1300 365 115 (Australia) 0800 729 389 (New Zealand) Carefully remove all packaging and transit protection from the heater before installation.
  • Page 2: Important Safety Information

    Owner’s Manual – Proflo 25/50 Litre Water Heater Important Safety Information WARNING – THIS APPLIANCE To dissipate this gas safely it is MAY DELIVER WATER AT HIGH recommended that a hot tap be turned on TEMPERATURE. REFER TO THE for several minutes at a sink, basin or bath, PLUMBING CODE OF AUSTRALIA but not a dishwasher, clothes washer or (PCA), LOCAL REQUIREMENTS AND...
  • Page 3 PTR Valve or are fitted with a combination thermostat and a faulty thermostat. over-temperature energy cut-out. Turn off the water heater and contact Dux This device must not be tampered with After Sales and Service. or removed. Replacement of this device...
  • Page 4 The pipework must Method for Clause G12 of the NZBC. Other not be used to support the water heater. methods of compliance are available. Dux recommends that installations conform with Where the water heater is subjected to wet AS/NZS 3500.4.
  • Page 5: Table Of Contents

    Owner’s Manual – Proflo 25/50 Litre Water Heater Contents Important Safety Information Installation Requirements Plumbing Connections Specifications Filling and Draining Electrical Connection System Maintenance Considering a Service Call? Warranty © Dux Manufacturing Limited 2021. All rights reserved. 028299 Rev. C...
  • Page 6: Plumbing Connections

    Owner’s Manual – Proflo 25/50 Litre Water Heater Plumbing Connections Relief Valve: Refer to AS/NZS 3500.4 for guidance on these The Pressure & Temperature Relief (PTR) Valve, types of installations. along with a brass reducer, is supplied loose with the water heater. Hot Water Connection: The hot water pipe is to be connected to a The PTR Valve rating is 1,000 kPa.
  • Page 7 If the index is greater than 0.80, the electrical heating element should be replaced with a low power density Incoloy heating element. Please consult Dux After Sales and Service for advice if required. Cold Water Connection: The water heater is intended to be permanently connected to the water supply main, and not connected by a hose-set.
  • Page 8: Specifications

    Owner’s Manual – Proflo 25/50 Litre Water Heater Specifications Single Handed 25L model Single Handed 50L model Dual Handed 25L & 50L models Specifications Relief Valve: Storage Capacity (L) 30.5 Pressure (kPa) 1000 Hot Water Delivery (L) Temperature (°C) Net Weight Empty (kg) Power Rating (kW) Element Sizes (kW) 2.4, 3.6...
  • Page 9: Filling And Draining

    Owner’s Manual – Proflo 25/50 Litre Water Heater Filling and Draining Filling the Water Heater: Draining the Water Heater: The water heater must be filled with water Turn off the electricity supply to the before turning on the electrical supply. water heater.
  • Page 10: Electrical Connection

    Owner’s Manual – Proflo 25/50 Litre Water Heater Electrical Connection General: Connections are made at the terminal block This water heater is designed for single phase under the water heater electrical cover, 230-240V a.c. supply only. The electrical and a means for disconnection must be connection must comply with Local Supply incorporated in the fixed wiring in accordance Authority Regulations and AS/NZS 3000.
  • Page 11: System Maintenance

    Owner’s Manual – Proflo 25/50 Litre Water Heater System Maintenance Regular servicing will help to extend the life Five Year Service: of the water heater, and keep it operating This service should only be carried out by a safely and efficiently. licensed tradesperson.
  • Page 12: Considering A Service Call

    • Is there a leaking hot water pipe or contact Dux After Sales and Service. dripping hot water tap? A small leak can waste a large quantity of hot water. Replace faulty tap washers and arrange for your plumber to rectify any leaking pipe work.
  • Page 13: Warranty

    During the period (as specified in the table contrary to this manual or other above), Dux will repair or replace any failed instructions provided by Dux; component or where necessary, in the absolute discretion of Dux, replace the water •...
  • Page 14 To the extent permitted by law the liability of transport), or paying the travelling time of an Dux shall be limited to the cost of the repair approved Dux agent to and from the owners or replacement of the water heater.
  • Page 15 Warranty claims can be placed by completing Dux Manufacturing Limited the following steps: Lackey Road Moss Vale, NSW, 2577 • Contact Dux on one of the numbers listed Australia below. 1300 365 115 (Australia) • Select the “Service” option followed by the “Hot Water”...
  • Page 16 Please take a moment to fill out your details for warranty Electric Storage Water Heaters registration at: www.dux.com.au/warranty For advice, repairs and service, call: or use your smartphone to scan this code: 1300 365 115 (Australia) 0800 729 389 (New Zealand)