Permissible limits of the voltage range at which the unit operates satisfactorily.
# Unit ampacity = 125 percent of largest operating component's full load amps plus 100 percent of all other potential operating components' (EAC, humidifier,
etc.) full load amps.
Time ---delay type is recommended.
{
Length shown is as measured one way along wire path between furnace and service panel for maximum 2 percent voltage drop.
}
1
Low Amp Kit (KGAPC0101ECM) allows select furnaces to be installed with a 15 Amp Breaker and 14 AWG wire within the listed wire length. Affected data
shown as Default Value/Value with Lower Amp Kit.
Fig. 37 - - Field- -supplied Isolation Relay for Humidifiers with Internal Power Supply
Table 11 – Electrical Data
OPERATING VOLTAGE
MAXIMUM
RANGE*
Maximum*
Minimum*
127
104
127
104
127
104
127
104
127
104
127
104
14.7/11.2
127
104
14.8/11.3
127
104
To Humidifier Leads
To Humidifier Leads
W2
COM
W/W1
Y/Y2
R
G
Fig. 38 - - Typical Two- -Stage Field Wiring Diagram