Use
CC1N7713en
15.06.2016
Photocell Detectors
The photocell detectors are designed for use with burner controls, for the super-
vision of yellow-flame oil flames.
They are used especially in connection with burner controls for the control and
supervision of large-capacity burners.
The RAR... and this Data Sheet are intended for use by OEMs which integrate the
flame detectors in their products!
The RAR... flame detectors are used for the supervision of yellow-burning oil flames.
They are designed for use with the following types of burner controls: LAL..., LAE1...,
LAE10..., LOK16..., LFS1.1...
Building Technologies Division
7
713
RAR...

Advertisement

loading

Summary of Contents for Siemens RAR Series

  • Page 1 RAR... Photocell Detectors The photocell detectors are designed for use with burner controls, for the super- vision of yellow-flame oil flames. They are used especially in connection with burner controls for the control and supervision of large-capacity burners. The RAR... and this Data Sheet are intended for use by OEMs which integrate the flame detectors in their products! The RAR...
  • Page 2 Warning notes To avoid injury to persons, damage to property or the environment, the following warning notes must be observed! Do not open, interfere with or modify the flame detector!  All activities (mounting, installation and service work, etc.) must be performed by qualified staff ...
  • Page 3 ISO 9001:2008 ISO 14001:2004 OHSAS 18001:2007 China RoHS Hazardous substances table: http://www.siemens.com/download?A6V10883536 Service notes Each time a unit has been replaced, check to ensure that wiring is in an orderly state and that the wires are firmly connected. Disposal notes The flame detector contains electrical and electronic components and must not be dis- posed of together with household waste.
  • Page 4 Type summary Artikel-Nr. Type Length of Clamp and flange Photocell reference detector cable *) made of BPZ:RAR9 RAR9 Max. 100 m Without clamp / flange Silicon BPZ:RAR9(1) RAR9(1) Max. 100 m With clamp and flange with radius Silicon BPZ:RAR9(2) RAR9(2) Max.
  • Page 5 Technical data General data Safety class Degree of protection IP20  Note! IP40 to DIN EN 60529, at relative design of cable entry (e.g. AGG09) Mounting position optional Weight approx. 85 g Cable connection Screw terminals for min. 0.5 mm² and max. 1,5 mm²...
  • Page 6 Dimensions Dimensions in mm 49...73 Accessories 4 199 8806 0 Clamp for direct mounting on the burner M4 E2 DIN 7952 7713m02/0716 4 241 8855 0 4 241 8898 0 R0.3 7712m10e/1001 Company logo to 7712m09e/1001 LN 3 8380 0102 Company logo to 0.2 mm elevated LN 3 8380 0102...