Ariston Thermo FAST EVO X Training Manual

Ariston Thermo FAST EVO X Training Manual

Instantaneous gas water heater 11, 14 low nox
Table of Contents

Advertisement

TRAINING MANUAL
FAMILY: Instantaneous Gas Water Heater
BRAND : ARISTON - CHAFFOTEAUX
MODEL: FAST EVO X - FLUENDO PLUS LNX
FAST R X - BRD LNX
TYPE : 11, 14 low NOx
version : 1V1
17/12/2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FAST EVO X and is the answer not in the manual?

Questions and answers

Summary of Contents for Ariston Thermo FAST EVO X

  • Page 1 TRAINING MANUAL FAMILY: Instantaneous Gas Water Heater BRAND : ARISTON - CHAFFOTEAUX MODEL: FAST EVO X - FLUENDO PLUS LNX FAST R X - BRD LNX TYPE : 11, 14 low NOx version : 1V1 17/12/2018...
  • Page 2 Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX Modification Fast Evo X “Display version” added 17/12/2018 18/07/2018 Creation of the document VERSION DATE NAME MODIFICATION Page. 2 di 64...
  • Page 3: Table Of Contents

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX INDEX GENERAL INFORMATION ..........................5 1.1 SIEZE & DIMENSIONS ............................5 1.1.1 FAST EVO X/FLUENDO PLUS LNX ........................ 5 1.1.2 FAST R X/BRD LNX ............................6 ............................. 7 OF THE APPLIANCE 1.2.1 FAST EVO X DISPLAY ............................
  • Page 4 Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX ................................46 MANIFOLD ELECTRIC CABLE ............................... 47 5.1 FAST EVO X/FLUENDO PLUS LNX ........................47 5.2 FAST EVO X DISPLAY ............................48 5.3 FAST R X/BRD LNX ............................. 49 ERROR CODE ...............................
  • Page 5: General Information

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 1 GENERAL INFORMATION 1.1 SIEZE & DIMENSIONS 1.1.1 FAST EVO X/FLUENDO PLUS LNX  Model 40.8 234.1 25.8 47.8 58,8 210.8 225.2 23.3 147.8 264.6 22.8 LEGEND A Hot water outlet...
  • Page 6: Fast R X/Brd Lnx

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 1.1.2 FAST R X/BRD LNX  Model 40.8 18.5 13.6 58.8 93.3 210.8 255.2 92.8 15.5 10.6 Page. 6 di 64...
  • Page 7: Hmi Of The Appliance

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX HMI OF THE APPLIANCE 1.2.1 FAST EVO X DISPLAY LEGEND 1 Reset 2 Temperature”-” button 3 Temperature ”+”button 4 “on/off” button Page. 7 di 64...
  • Page 8: Fast Evo X/Fluendo Plus Lnx

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 1.2.2 FAST EVO X/FLUENDO PLUS LNX LEGEND 1 Knob 2 Scale of temperature 3 Led 1.2.3 FAST R X/BRD LNX 1.2.4 Information with the LED If the LED is fixed: the power of the batteries is too low, changed them.
  • Page 9: Detailed Description

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX DETAILED DESCRIPTION 1.3.1 FAST EVO X/FLUENDO PLUS LNX LEGEND 1. Fume thermostat PCB box 2. Exhaust hood Flow sensor 3. Heat exchanger 10. Ignition PCB 4. Burner 11. knob 5.
  • Page 10: Fast R X/Brd Lnx

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 1.3.2 FAST R X/BRD LNX LEGEND 1. Exhaust hood 8. Water gas valve 2. Heat exchanger 9. Overheat thermostat 3. Burner 10. Gas connect pipe 4. Water connect pipe 11.
  • Page 11: Preparation For Wall Mounting (New Installation)

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX PREPARATION FOR WALL MOUNTING (NEW INSTALLATION) 1.4.1 FAST EVO X/FLUENDO PLUS LNX Place the securing plate marking hole A above the water inlet line and to the left of the water line perpendicular.
  • Page 12: Fast R X/Brd Lnx

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 1.4.2 FAST R X/BRD LNX FAST 617.4 485.8 114.2 52.8 53.2 18.4 13.5 93.3 FAST 617.4 485.8 52.3 53.7 15.5 10.6 Recommandations  Position the water heater as close as possible to the flue exhaust.
  • Page 13: Hydraulic Diagram

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 1.5 HYDRAULIC DIAGRAM 1.5.1 FAST EVO X/FLUENDO PLUS LNX LEGEND 1. Heat exchanger Ignitor 2. Hot water outlet Battery (number 2) 3. Burner Hot water NTC sensor 4. Ignitor sensor Knob for setting the temperature 5.
  • Page 14: Fast R X/Brd Lnx

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 1.5.2 FAST R X/BRD LNX LEGEND Heat exchanger Magnetic plug Wet chamber Water valve Burner Control unit Ignition electrode Over heat thermostate Ionisation electrode Safety exhaust fume Gas valve...
  • Page 15: Operation Logic

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 2 OPERATION LOGIC 2.1 FAST EVO X/FLUENDO PLUS LNX When water faucet is turned on, if the water flow rate is over (>2 l/mn), electrical impulse will be input...
  • Page 16 Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX Water flow > 2 l/min Mesasure of the flow rate Ignition cycle Safety gas valve (9 et 10) Gas valve (20 et 21) Ignitor (12) Detection (5) Ionistation current> 0,5 uA...
  • Page 17: Fast R X/Brd Lnx

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 2.2 FAST R X/BRD LNX Turn on the power switch, when the tap is turned on, the water flow is more than (2L/min) or the water pressure is higher than 0.2bar, the micro-switch (15) gives the electrical signal to the ignition controller (A).
  • Page 18 Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX The thermostat (E) monitor water temperature inside HEX, when exhaust gas goes out of flue hood and flue hood temperature exceeds 145 ℃, the machine stops working. (Machine only for RU market has this function) Right knob(9)...
  • Page 19: Management Of The Appliance

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 2.3 MANAGEMENT OF THE APPLIANCE 2.3.1 FAST EVO X/FLUENDO PLUS LNX TEMPERATURE 35°C 65°C RANGE Variation of the temperature by the knob The sanitary tap is detected by the proportional...
  • Page 20: Fast R X/Brd Lnx

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 2.3.2 FAST R X/BRD LNX TEMPERATURE 35°C 65°C RANGE Variation of the temperature by the knob SANITARY TAP The sanitary tap is detected by water pressure After dection flame, there is verification of the...
  • Page 21: Special Function

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 2.4 SPECIAL FUNCTION 2.4.1 ANTIFREEZE FUNCTION If the appliance is installed where is possible that the temperature goes down 5°C, we suggest to drain the water. 2.4.2 SOLAR FUNCTION The opening temperature for the thermostatique is 48°C...
  • Page 22: Hydraulic Components

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 3 HYDRAULIC COMPONENTS 3.1 FAST EVO X/FLUENDO PLUS LNX 3.1.1 HYRAULIC BLOCK - Inlet Water flow sensor Filter Inlet cold water Selector of water flow Reed sensor Cold water...
  • Page 23: Hydraulic Block - Outlet

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 3.1.2 HYDRAULIc BLOCK - outlet NTC sensor outlet Hot water connection NTC outlet sensor Page. 23 di 64...
  • Page 24: Heat Exchanger

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 3.1.3 HEAT EXCHANGER The heat exchanger is in copper and the pipe is in series. There are 2 different dimensions of the heat exchanger, depend on the power.
  • Page 25: Sanitary Flowmeter

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 3.1.5 SANITARY FLOWMETER When there is a sanitary tap, the flow of water passes through the turbine that allows the electronic card to measure the flow by means of a reed sensor.
  • Page 26: Overheat Sensor

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 3.1.7 OVERHEAT SENSOR The overheat thermostat is located on the heat exchanger. The opening of contact of overheat thermostat (85°C) causes boiler safety shutdown. To restart the appliance the temperature must be go down the normal operating values of the thermostat (80°C) and: ON/OFF on the flow rate.
  • Page 27: Fast R X/Brd Lnx

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 3.2 FAST R X/BRD LNX 3.2.1 HEAT EXCHANGER The heat exchanger is in copper and the pipe is in series. There are 3 different dimensions of the heat exchanger, depend on the power.
  • Page 28: Safety Fume Sensor

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 3.2.3 SAFETY FUME SENSOR Fixed on the left side of the air intake hole by 2 screw. The safety device is connected in series with the overheater. Datas: Cut of temperature: All models: 145°C...
  • Page 29: Gas

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 4 GAS 4.1 FAST EVO X/FLUENDO PLUS LNX The valve gas is equiped with safety gas valve and a motor for the coil of the regulation of the principal main valve..
  • Page 30 Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX Solenoid Motor (rep 20) and solenoid coil (rep 21) Gas diaphragm rep 7 Motor rep 20 coil rep 21 Page. 30 di 64...
  • Page 31: Fast R X/Brd Lnx

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 4.2 FAST R X/BRD LNX The valve is equiped with water valve, gas valve, interstage valve,microswitch, Page. 31 di 64...
  • Page 32: Setting Gas

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 4.3 SETTING GAS 4.3.1 FAST EVO X DISPLAY 4.3.1.1 MEASURE OF THE GAS PRESSURE Supply pressure check 1. Unscrew the screw “b” and insert the pressure gauge fitting pipe in the pressure intake.
  • Page 33 Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 4.3.1.2 Parameter setting To access the paramters simultaneously press the “-” and “+” buttons for 3 seconds, the display will show “PA”. To select the other parameters press “+”button.
  • Page 34 Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 4.3.1.3 MAX burner pressure setting 1. Close the gas valve; 2. Unscrew the screw “a” and insert the manometer connection pipe into the pipe tap 3. Open the gas valve 4.
  • Page 35: Fast Evo X/Fluendo Plus Lnx

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 2. Unscrew the screw “a” and insert the manometer connection pipe into the pipe tap 3. Open the gas valve 4. Press “on/off” button the display will show 5.
  • Page 36 Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX Machine model selection Switch Gas nat Gas nat Page. 36 di 64...
  • Page 37 Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX Gas category selection Gas nat Gas nat Note: The setting of gas/model should be done before assembled the battery, make sure the knob is on the open position. Any change in the working mode is useless.
  • Page 38 Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 4.3.2.3 Setting the maximum burner pressure gas Inlet pressure gas: b.* Pressure gas on the burner: a Removed the batteries before setting Open the sanitary tap. Put the Switch 1 on ON : Test Mode.
  • Page 39 Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX Inlet pressure gas: a Pressure gas on the burner:b Open the sanitary tap. Put the Switch 1 on ON : Test Mode. Put the Switch 2 / Switch 3 OFF : Mini Power.
  • Page 40 To removed the gas diaphragm, and change the appliance to natural gas to GPL (or reverse), you must do:  Change the manifold and diaphragm gas.  Set the micro switchs on the main PCB (see table) for FAST EVO X or set on display the “PA” for FAST EVO X DISPLAY.
  • Page 41 Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX  New diaphragme gas  New manifold Be carefull that the TIP must enter in the hole of the membrane, if not there is no mouvement of it.
  • Page 42: Fast R X/Brd Lnx

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 4.3.3 FAST R X/BRD LNX 4.3.3.1 Supply pressure check 1. Close the gas valve. 2. Loosen screw “b” and insert the pressure gauge connection pipe into the pipe tap.
  • Page 43 Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 6. Check the maximum burner pressure. The pressure should correspond to the value established in relation to the type of gas for which the appliance is MAXIMUM BURNER PRESSURE (mbar) designed.
  • Page 44 Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX Page. 44 di 64...
  • Page 45: Burner

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 4.4 BURNER The low NOx emission is realized by the low NOx burner, the inlet water go through the burner blades result to cooling down the burner, thus a lower flame temperature is approached.
  • Page 46: Position Of The Probes On The Burner

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX Position of the probes on the burner 4.6 MANIFOLD Page. 46 di 64...
  • Page 47: Electric Cable

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 5 ELECTRIC CABLE 5.1 FAST EVO X/FLUENDO PLUS LNX LEGEND 1. Ignition Electrode Knob for the temperateur setting 2. Ionisation Electrode Overheat temperature flue gas and water 3. Gas valve NTC outlet sensor 4.
  • Page 48: Fast Evo X Display

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 5.2 FAST EVO X DISPLAY Page. 48 di 64...
  • Page 49: Fast R X/Brd Lnx

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 5.3 FAST R X/BRD LNX LEGEND 1.Gas collector 5.Thermostat(85℃&140℃) 2.Battery 6.LED 3.Power switch 7.P.C.B 4.Gas water valve 8.Ignite pin &flame sensor pin Page. 49 di 64...
  • Page 50: Error Code

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 6 ERROR CODE The Led on the control box who is green normally, turns red with an error code. This led flash during the error code as follow :...
  • Page 51: Troubleshooting- Fast Evo X/Fluendo Plus Lnx

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX TROUBLESHOOTING- FAST EVO X/FLUENDO PLUS LNX 6.1.1 Flashing (micro switch not correct) Single Flashing Micro-switch not in correct (x1) position Check the position of the micro switch with the instruction booklet 6.1.2 Flashing (Temperature sensor out)
  • Page 52: Flashing (No Flame Detected)

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 6.1.3 Flashing (No flame detected) Flashing Triple No flame detected (x3) Insufficient Check the static pressure gas Check the pressure pressure gaz between reducer of the installation 17 et 25 mb natural gas...
  • Page 53: Flashing (Problem On The Gas Valve)

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 6.1.4 Flashing (Problem on the gas valve) Quadruple flashing Problem on the gas valve (x4) Problem on the gas valve Replace the gas Check the valve gaz gas valve...
  • Page 54: Flashing (Fume Temperature Too High)

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 6.1.5 flashing (Fume temperature too high) flashing Quintuple Fume temperature too hight (x5) Gas pressure Check the dynamic too hight Set the pressure reducer of pressure gaz between...
  • Page 55: Troubleshooting-Fast R X/Brd Lnx

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 6.2 TROUBLESHOOTING-FAST R X/BRD LNX 6.2.1 Flashing (Low voltage) Flashing Low voltage Change batteries 6.2.2 No ignition No ignition Water pressure is Check water Increase water pressure flow...
  • Page 56: Ignition But Not Successful

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX Ignition but not successful 6.2.3 Ignition but not successful Insufficient pressure gas or Check inlet gas type Check the gas type and not correct gas and pressure pressure reducer of the...
  • Page 57: Fast Evo X Display

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 6.3 FAST EVO X DISPLAY 6.3.1 E2 (Water temprerature sensor failure) Water temperature sensor failure Check the Pressure < 0,1 b Increased the pressure water P > 0,1 b...
  • Page 58: E3 (Igniton Failure Or Flame Lift)

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 6.3.2 E3 (igniton failure or flame lift) Ignition failure or flame lift Insufficient Check the static pressure gas Check the pressure pressure gaz between reducer of the installation...
  • Page 59: E4 (Gas Vavle Defective)

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 6.3.3 E4 (gas vavle defective) Gas valve defective Problem on the gas valve Replace the gas Check the valve gaz gas valve Gas valve correct Doesn’t open Replace the gas...
  • Page 60: E5 (Overheat)

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 6.3.4 E5 (overheat) Overheat Gas pressure Check the dynamic too hight Set the pressure reducer of pressure gaz between the installation 17 et 25 mb natural gas and 28 et 40 GPL...
  • Page 61: Technical Specification

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX 7 TECHNICAL SPECIFICATION Page. 61 di 64...
  • Page 62 Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX Page. 62 di 64...
  • Page 63 Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX Page. 63 di 64...
  • Page 64: Page. 3 Di

    Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX Page. 64 di 64...

Table of Contents