Mazona Stoves Glencara Operation And Installation Manual

Mazona Stoves Glencara Operation And Installation Manual

Advertisement

Glencara/Ripley Stove Range
Eco-design Compliant
Operation and Installation Manual
Glencara/ Ripley 4kW MZEDGCMF4, Glencara/ Ripley 5kW
MZEDGCMF5, Glencara/ Ripley 8kW MZEDGCMF8
Version 2 – 09/06/2021
PLEASE RETAIN FOR FUTURE REFERENCE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Glencara and is the answer not in the manual?

Questions and answers

Summary of Contents for Mazona Stoves Glencara

  • Page 1 Glencara/Ripley Stove Range Eco-design Compliant Operation and Installation Manual Glencara/ Ripley 4kW MZEDGCMF4, Glencara/ Ripley 5kW MZEDGCMF5, Glencara/ Ripley 8kW MZEDGCMF8 Version 2 – 09/06/2021 PLEASE RETAIN FOR FUTURE REFERENCE...
  • Page 2: The Clean Air Act 1993 And Smoke Control Areas

    Clean Air Act requirements. The Mazona Glencara/ Ripley 4kW, 5kW and 8kW must be fitted with a mechanical stop to prevent closure of the secondary air controls beyond 6mm open, 6mm open and 10mm open retrospectively.
  • Page 3 Welcome to Mazona Congratulations on purchasing your very own Mazona stove. We’re sure you can’t wait to get started, but please, read this manual thoroughly. You’ll learn the ins and outs of using your stove and we promise you, you’ll hit the ground running. We’d like to thank you for supporting Mazona, a brand which strives to produce reliable, eco-friendly stoves at an affordable price.
  • Page 4 IMPORTANT It is important that this manual is read by the installer before installation. The householder should familiarise themselves with the manual before using the appliance. Incorrect installation of this stove can be dangerous. The installation should be carried out by a trained competent person and in accordance with local and national building regulations.
  • Page 5: Installation Instructions

    See below for suggested distance to combustible materials. Distance to Front Side Back Hearth combustibles. Temp. Glencara/Ripley 4kw 100cm 50cm 60cm >100°C Glencara/Ripley 5kw 100cm 50cm 60cm >100°C...
  • Page 6: Flue / Chimney

    Extraction fans lower the pressure in a building which can cause spillage of combustion products from an open-flued appliance. This can occur even if the appliance and the fan are in different rooms. If mechanical extraction is unavoidable in the same room as your stove, then seek specialist advice to ensure safe operation of the appliance.
  • Page 7: Hearth Construction

    Provision should be made to ensure the chimney can be swept in the entirety of its length. For local building regulations, please see page 4. If using single wall flue, please ensure there is a clearance of at least 3 times the diameter of the flue pipe from any combustible material (e.g.
  • Page 8: Lighting The Stove

    2) OPERATION INSTRUCTIONS Lighting the stove 1. Open the door and ensure the secondary/ air-wash control lever is opened fully. It’s the control on the right. 2. On first lighting, we recommend using 2 - 3 firelighters along with wood kindling built in a pyramid above the firelighters to obtain a good fire bed.
  • Page 9: Recommended Fuels

    Burning coal: • The Air-wash/secondary air lever (The control to the right) – This should be left partially open, to allow the air-wash system to keep the glass clean. • Primary air control lever (The control to the left) - When burning coal, the stove should be mainly controlled using this lever.
  • Page 10 If there are too few embers in the fire bed, add suitable kindling to prevent excessive smoke. Fuel constraints Glencara/Ripley Glencara/Ripley Glencara/Ripley Max fuel load 0.92kg...
  • Page 11 Weather Conditions Weather conditions can affect the performance of the stove. Strong winds combined with close buildings or trees can cause the stove to smoke. Heavy rain may lower the temperature of the flue making it difficult to light or slow to heat up.
  • Page 12: Troubleshooting (Faq)

    3) Troubleshooting/ F.A.Q. Problem Probable Cause Recommended Action Fire difficult to light Green/Wet wood Use recommended fuels Insufficient air Open air controls Insufficient draft Check flue is not obstructed, sweep if needed Fuel too large Use kindling / small logs to start fire Fire burns too quickly Too much air...
  • Page 13 Low heat output Poor quality fuel Use recommended fuels Insufficient Seal Check condition of rope seal around glass Page 13 of 24...
  • Page 14: Important Notice

    IMPORTANT NOTICE WARNING: When properly installed and operated this appliance should only emit fumes during fuelling and de-ashing. The stove is designed to be operated only with the doors shut. To prevent fume spillage only open the doors for ignition, refuelling and cleaning.
  • Page 15: Maintenance

    4) MAINTENANCE De-ashing The appliance should be de-ashed at least once every 24 hours depending on fuel type and heating load. With the door closed, use the riddling lever on the left side to filter the ash through the grate and into the ash pan below for removal.
  • Page 16: Flue / Chimney Cleaning

    Paintwork If paintwork needs repaired, contact your retailer directly. The paint used on your product is specialised high temperature resistant paint and ordinary paint will not suffice. Never perform any paint repair when unit is hot. Flue / Chimney cleaning Please ensure the flue is swept as instructed.
  • Page 17: Technical Information

    5) TECHNICAL INFORMATION Appliance Glencara/Ripley Glencara/Ripley Glencara/Ripley Fuel type Beech Anthracite Beech Anthracite Beech Anthracite Output kW (nominal) Efficiency (%) 75.4 79.2 75.6 86.5 79.0 79.6 CO Emissions 0.10 0.09 0.12 0.10 0.10 0.08 at 13% O (vol%) Emissions at 13% O...
  • Page 18 6) DIMENSIONS Maximu Weig Height(m Width(m Depth(m Collar (mm) (kg) length Appliance (mm) 250mm 5”/125m Glencara/Rip 487mm 380mm 292mm 59.5 ley 4kW 100mm 250mm 5”/125m Glencara/Rip 487mm 380mm 342mm ley 5kW 100mm 350mm 5”/125m Glencara/Rip 530mm 490mm 362mm 90.5 ley 8kW...
  • Page 19: Product Drawings

    7) PRODUCT DRAWINGS Glencara/Ripley 4kW Glencara/Ripley 5kW Page 19 of 24...
  • Page 20 Glencara/Ripley 8kW Page 20 of 24...
  • Page 21: Exploded Diagram

    EXPLODED DIAGRAM Page 21 of 24...
  • Page 22: Spare Parts List

    8) SPARE PARTS LIST Product Part Part number Quantity Door Glass Left side brick Right side brick Back brick Baffle Baffle brick Flue collar Baffle brick fixing bar Blanking Plate Outside air back cover Ashpan Ashpan tool Bottom grate Bottom grate support Riddling bar Outside air bottom cover...
  • Page 23: Warranty

    9) WARRANTY 5 Years – Your warranty covers replacement of the stove body if it is found to be defective within 5 years of purchase. Refitting and shipping costs are not covered. 1 Year – Bottom grate, bottom grate support, cast iron door, riddling bar, air control bars, fire bars, ashpan, flue collar &...
  • Page 24: Warranty Claim Form

    WARRANTY CLAIM FORM PLEASE ENSURE ALL MANDATORY SECTIONS (*) ARE CORRECTLY COMPLETED OR WE WILL NOT BE ABLE TO PROCESS YOUR CLAIM Customer name* Customer Address* Post Code* Date* Contact Number(s)* Retailer Name* Retailer Contact* Date of Purchase Type of fuel used* Problem reported* Comments Date of Installation*...