H
WARNING
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other
fl ammable liquids in the vicinity of this
or any other boiler.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any boilers.
Do not touch any electrical switches,
do not use any phone in your building.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas supplier,
call the fi re department.
Installation and service must be
performed by a qualifi ed installer,
service agency or the gas supplier.
WARNING
Improper installation, adjustment, and/
or operation could cause carbon monoxide
poisoning resulting in injury or loss of life.
This product must be installed and serviced
by a professional service technician who is
experienced and qualified in hot water boiler
installation and gas combustion.
Product may not be exactly as shown
IMPORTANT
Read and save these instructions
for future reference.
Please file in Service Binder

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VITODENS 100-W B1HE and is the answer not in the manual?

Questions and answers

Summary of Contents for Viessmann VITODENS 100-W B1HE

  • Page 1 Operating Instructions for the system user Vitodens 100-W B1HE Series and B1KE Combi Series Wall mounted gas-fired condensing boiler with 3.5 inch black/white display On demand domestic Hot Water with Combi Boilers For operation with natural gas or liquid propane gas Heating Input: 8.5 to 199 MBH 2.5 to 58.3 kW VITODENS 100-W...
  • Page 2: Safety, Installation And Warranty Requirements

    Follow the manufacturing facilities. Viessmann maintenance schedule of the boiler contained in this manual. Contaminated combustion air will damage the boiler and may lead to substantial property damage, severe Operating and Service Documentation personal injury and/or loss of life.
  • Page 3: Table Of Contents

    Table of Contents Vitodens 100-W B1HE/B1KE Operating Page Safety Safety, Installation and Warranty Requirements ..... 2 About these Instructions..........5 For your Safety ............5 Operation ............. 5 Working on the equipment ........5 Maintenance and cleaning ........5 Flue gas smell ............5 Dangerous conditions ..........
  • Page 4 Table of Contents Vitodens 100-W B1HE/B1KE Operating Page Calling Up Information Calling Up Help Messages .........23 Checking Information ..........23 Checking the Energy Metering........23 Calling Up Licences for the Programming Unit ....23 Calling Up Licences for the Integrated Wireless Module .. 23 Checking Service Messages ........24...
  • Page 5: About These Instructions

    Safety Vitodens 100-W B1HE/B1KE Operating About these Instructions Take note of all symbols and notations intended to draw attention to potential hazards or important product information. These include “WARNING”, “CAUTION”, and “IMPORTANT”. See below. Warnings draw your attention to the presence of WARNING potential hazards or important product information.
  • Page 6: Carbon Monoxide

    Flue products contain poisonous carbon monoxide gas which can cause nausea or asphyxiation Note: Viessmann does not test any detectors and makes resulting in severe personal injury or loss of life. no representation regarding any brand or type of detector.
  • Page 7: Frozen Water Pipe Hazard

    Safety Vitodens 100-W B1HE/B1KE Operating For your Safety (continued) Frozen water pipe hazard Installation area conditions Your heating boiler is designed to provide a warm and comfortable living environment. It is not designed to WARNING ensure against freezing of water pipes.
  • Page 8: Intended Use

    General Information Vitodens 100-W B1HE/B1KE Operating Intended Use The boiler is only intended to be installed and operated in sealed unvented heating systems with due attention paid to the associated installation, service and operating instructions. It is only designed for the heating of water that is of potable water quality.
  • Page 9: Software Licences

    General Information Vitodens 100-W B1HE/B1KE Operating Software Licences This product contains third party software, including open source software. You are authorized to use this third party software in compliance with the relevant licensing terms. Licences for the integrated wireless module: See page 23.
  • Page 10: Energy Saving Tips

    General Information Vitodens 100-W B1HE/B1KE Operating Energy Saving Tips Saving energy when using central heating Do not overheat your home. Every degree of room temperature reduction saves up to 6% on your heating bills. Weather-compensated operation: Do not set your standard room temperature (temperature level “Standard”) higher than 68°F (20°C)
  • Page 11: Operating Principles

    Operation Vitodens 100-W B1HE/B1KE Operating Operating Principles Display Status display with Lightguide You can adjust any setting on your system centrally at A red illuminated strip (Lightguide) is displayed at the the control unit. lower or upper edge of the control unit during operation.
  • Page 12: System Overview

    Operation Vitodens 100-W B1HE/B1KE Operating System Overview Depending on the system equipment level, you can check the most important information in the system overview: Heating DHW (home screen) Note: Not valid for systems with a DHW tank with temperature switch (such as an Aquastat).
  • Page 13: Procedure For Setting Program

    Time Programs Vitodens 100-W B1HE/B1KE Operating Procedure for Setting a Time Program The following explains how to input the settings for a time program. The specifics of the individual time programs can be found in the relevant chapters. Time programs and time phases Not valid for operation with a DHW tank with temperature switch (such as an Aquastat).
  • Page 14 Time Programs Vitodens 100-W B1HE/B1KE Operating Procedure for Setting a Time Program (continued) Tap the following buttons: Copying the time program to other days of the week 1. Call up the home screen. Explanation of the procedure for DHW. Example: You want to copy the time program for “Monday”...
  • Page 15 Time Programs Vitodens 100-W B1HE/B1KE Operating Procedure for Setting a Time Program (continued) Changing time phases Deleting time phases Explanation of the procedure using DHW as an example. Explanation of the procedure using DHW as an example. Example: Example: For “Monday”, you want to change the end time for For “Monday”, you want to delete time phase 2.
  • Page 16: Dhw Temperature

    DHW Heating Vitodens 100-W B1HE/B1KE Operating DHW Temperature Note: When operating with a DHW tank with temperature For the Vitodens 100-W B1KE with instantaneous DHW switch (such as an Aquastat), the maximum target a scalding label is placed on the side of the boiler.
  • Page 17: Switching Dhw Heating On Or Off

    DHW Heating Vitodens 100-W B1HE/B1KE Operating Switching DHW Heating On or Off Tap the following buttons: 1. Call up the home screen. for “Turn on/off” 4. OK to confirm for “DHW” 6. OK twice to confirm for “ON” or “OFF”...
  • Page 18: Increased Dhw Hygiene

    DHW Heating Vitodens 100-W B1HE/B1KE Operating Increased DHW Hygiene Switching on the “Hygiene program” WARNING Tap the following buttons: 1. Call up the home screen. High DHW temperatures can cause scalding, for “DHW” e.g. if the DHW temperature is above 140°F (60°C).
  • Page 19: Setting The Display Brightness

    Further Adjustments Vitodens 100-W B1HE/B1KE Operating Setting the Display Brightness Tap the following buttons: 1. Call up the home screen. for “Settings” 4. OK to confirm for “Display brightness” 6. OK to confirm for “Display” 8. OK to confirm for the selected value 10.
  • Page 20: Setting The "Time" And "Date

    Further Adjustments Vitodens 100-W B1HE/B1KE Operating Setting the “Time” and “Date” The “Time” and “Date” are set at the factory. If your Set the date system has been shut down for a prolonged period, Tap the following buttons: you may need to reset the “Time” and “Date”.
  • Page 21: Summertime/Wintertime Automatic Changeover

    Further Adjustments Vitodens 100-W B1HE/B1KE Operating Summertime/Wintertime Automatic Changeover Tap the following buttons: 1. Call up the home screen. for “Settings” 4. OK to confirm for “Date and time” 6. OK to confirm for “Time” 8. OK to confirm for “Time changeover”...
  • Page 22: Switching Internet Access On Or Off

    Further Adjustments Vitodens 100-W B1HE/B1KE Operating Switching Internet Access On or Off You can control your system remotely via the internet Establishing a WiFi connection using an app. To do this, establish an internet connection Tap the following buttons: via WiFi: See the following chapter.
  • Page 23: Calling Up Help Messages

    Calling Up Information Vitodens 100-W B1HE/B1KE Operating Calling Up Help Messages You can call up help messages relating to some of the displays and functions. Tap the following buttons: within the menu if necessary for “Help” 2. OK to confirm...
  • Page 24: Checking Service Messages

    Calling Up Information Vitodens 100-W B1HE/B1KE Operating Calling Up Licences for the Integrated Wireless Module (continued) Third party software Acknowledgements Linux® is the registered trademark of Linus Torvalds in Overview the U.S. and other countries. This product includes This product contains third party software, including software developed by the OpenSSL Project for use in open source software.
  • Page 25: Checking Fault Messages

    Calling Up Information Vitodens 100-W B1HE/B1KE Operating Checking Fault Messages If your system has developed faults, “Burner fault” or WARNING “Active messages” are displayed. The Lightguide is flashing: See chapter “Switching the Lightguide on and If faults are not rectified, they may have life threatening off”.
  • Page 26: Acknowledging Messages

    Calling Up Information Vitodens 100-W B1HE/B1KE Operating Acknowledging Messages Tap the following buttons: 1. Call up the home screen. for “Active messages” 4. OK to confirm for “Acknowledge” 6. OK to confirm 7. OK to acknowledge the information All pending messages are acknowledged.
  • Page 27: Emissions Test Mode

    Emissions Test Mode Vitodens 100-W B1HE/B1KE Operating Emissions Test Mode Emissions test mode must only be activated by licensed professional heating contractor during the annual inspection. If possible, have the emissions test carried out during the heating season. Emissions test mode is switched on via the service menu.
  • Page 28: Switching Off The Boiler Without Frost Protection Monitoring

    Switching On and Off Vitodens 100-W B1HE/B1KE Operating Switching Off the Boiler Without Frost Protection Monitoring No central heating No DHW heating Frost protection for the boiler and the DHW tank is not active. 1. Turn off the ON/OFF switch.
  • Page 29: Rooms Are Too Cold

    What to do if... Vitodens 100-W B1HE/B1KE Operating Rooms are too Cold Cause Remedy The boiler is switched off. Turn on the ON/OFF switch: See page 28. Switch on the power supply to your system, e.g. at a separate MCB/fuse or mains isolator.
  • Page 30: There Is No Hot Water

    What to do if... Vitodens 100-W B1HE/B1KE Operating There is no Hot Water Cause Remedy The boiler is switched off. Turn on the ON/OFF switch Switch on the power supply to your system, e.g. at a separate MCB/fuse or mains isolator.
  • Page 31: Cleaning

    Maintenance Vitodens 100-W B1HE/B1KE Operating Cleaning The boilers can be cleaned with a commercially available domestic cleaning agent (non-scouring). Clean the surface of the operating unit with a microfiber cloth. Inspection and Maintenance Regular maintenance ensures trouble-free, energy efficient, environmentally responsible and safe heating.
  • Page 32: Overview Of "Main Menu

    Appendix Vitodens 100-W B1HE/B1KE Operating Overview of “Main menu” Note: Depending on the features of your system, not all Tap the following buttons: 1. Call up the home screen. of the displays and checks listed may be available under for the required information.
  • Page 33 Appendix Vitodens 100-W B1HE/B1KE Operating Overview of “Main menu” (continued) Note: Depending on the features of your system, not all Tap the following buttons: of the displays and checks listed may be available. 1. Call up the home screen. for the required menu.
  • Page 34 Appendix Vitodens 100-W B1HE/B1KE Operating Overview of “Main menu” (continued) Information Boiler information Burner Status Boiler serial number Device serial number Software version Burner hours run Thermostat function Heating circuit pump Type of heating Slope Level Altitude at the installation site...
  • Page 35: Terminology

    Appendix Vitodens 100-W B1HE/B1KE Operating Terminology Standby mode Heating operation Boiler is switched off. Only frost protection of boiler and Operating modes DHW tank is active. No central heating, no DHW heating To heat your home, the boiler provides heat as specified System version by the set supply temperature.
  • Page 36 Appendix Appendix Vitodens 100-W B1HE/B1KE Operating Terminology (continued) Heating curve slope Heating curve Heating curves illustrate the relationship between the outside temperature, the target room temperature and the supply temperature. The lower the outside temperature, the higher the supply temperature.
  • Page 37 Appendix Vitodens 100-W B1HE/B1KE Operating Terminology (continued) Heating circuit pump Circulation pump for circulating the heating water in the heating circuit Room air dependant operation The combustion air is drawn from the room where the boiler is installed. Direct vent operation Combustion air is drawn from outside the building.
  • Page 38: Lighting And Operating Instructions

    Appendix Vitodens 100-W B1HE/B1KE Operating Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE OPERATING W A R N I N G: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 39 Vitodens 100-W B1HE/B1KE Operating...
  • Page 40 Vitodens 100-W B1HE/B1KE Operating Scan for digital copy of this document...

This manual is also suitable for:

Vitodens 100-w b1ke

Table of Contents

Save PDF