Safety Warnings
All electrical work should be performed by a licensed electrician.
WARNING: Risk of electrical shock. Disconnect power to the pump before servicing. Do not handle the
pump with wet hands or when standing on a wet or damp surface.
WARNING: Risk of fire or explosion. Pump water only with this pump. Do not use this pump in the presence
of flammable or explosive vapors.
CAUTION: Motors run hot. Do not touch the motor housing during operation.

Utility Sink Pump - LTS250A, SBA025HPACK

Problem 1: Pump does not run when water flows in from the sink.
Possible Causes
1. The pump is not plugged in.
2. The circuit breaker has tripped.
3. The pump impeller is stuck.
4. The sink stopper is in the drain.
5. Not enough water to activate the pump.
6. Diaphragm switch has failed.
Problem 2: Pump runs but does not empty sink.
Possible Causes
1. The drain is clogged.
2. The discharge line is clogged.
3. The check valve is installed incorrectly.
Problem 3: Pump cycles ON and OFF when there is no water in the sink.
Possible Causes
1. The check valve is not installed.
2. The check valve is jammed.
Problem 4: Pump cycles ON and OFF when the sink is full.
Possible Causes
1. The shut-off valve is not installed.
2. The shut-off valve is out of adjustment.
1. Make sure the plug is connected.
2. Reset the circuit breaker by switching the breaker to the "ON" position.
3. Unplug the pump. To clear the impeller, Refer to "Maintenance" in the
owner's manual.
4. Remove the stopper.
5. Keep water running until the pump turns on.
6. Refer to the owner's manual and verify the installation is correct on the
discharge side. Contact customer support for next steps.
1. Clear the drain screen.
2. Unplug the pump, open and clear the discharge line.
3. Make sure the flow arrow on the check valve points away from the
pump.
1. Unplug the pump. Refer to the "Installation" section of the owner's
manual to install the check valve properly.
2. Unplug the pump. Open the discharge line and clean the check valve.
1. Unplug the pump. Refer to the "Installation" section of the owner's
manual to install the shut-off valve.
2. Refer to "Adjusting the Flow" section of the owner's manual to correctly
adjust the shut-off valve.
2
Corrective Action
Corrective Action
Corrective Action
Corrective Action
Everbilt Utility Pump Troubleshooting Guide

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LTS250A and is the answer not in the manual?

Questions and answers

Beatrice
January 26, 2025

Need help in finding why it keeps running g

1 comments:
Mr. Anderson
February 10, 2025

The Everbilt LTS250A may keep running due to the following reasons:

1. Check valve is not installed – Install the check valve properly as per the owner's manual.
2. Check valve is jammed – Unplug the pump, open the discharge line, and clean the check valve.

These issues can cause the pump to cycle ON and OFF even when there is no water in the sink.

This answer is automatically generated