Preface Congratulations to your new PrimuX ISDN card, a high performance adapter for professional communications. This manual will guide you through installation and configuration of the PrimuX ISDN adapter. We wish you lots of success with our ISDN adapters! Sincerely, Gerdes AG...
Contents Preface Contents Copyright notice License Agreement Copyright License Upgrades Term Limited Warranty Customer Remedies No Other Warranties No Liability for Consequential Damage Limit of Liability Right to Audit Supplementary Software U.S. Government Restricted Rights Contractor/ manufacturer is: News and Updates Customer Services Software Requirements...
Gerdes Aktiengesellschaft does not provide any intellectual property licenses with the sale of PrimuX products other than a license to use such product in accordance with intellectual property owned or validly licensed by Gerdes Aktiengesellschaft or its subsidiaries.
License Agreement This is an Agreement between you the Company and your Affiliates (referred to in some instan- ces as ''You'' and in other instances as ''Company'') and all your Authorized Users and Gerdes Aktiengesellschaft (''Gerdes''). YOU SHOULD CAREFULLY READ THE FOLLOWING TERMS AND CONDITIONS BEFORE INSTALLING OR DOWNLOADING THE SOFTWARE.
Limited Warranty The only warranty Gerdes makes is that the medium on which the Program is recorded will be replaced without charge if Gerdes, in good faith, determines that it was defective in materials or workmanship and if returned to your supplier with a copy of your receipt within ninety (90) days from the date you received it.
Program, even if Gerdes has been advised of the possibility of such damages. As some jurisdictions do not allow the exclusion or limitation for certain damages, some of the above limitations may not apply to You or your Authorized Users.
(3%) or more of the Authorized Users within the Company. If material discrepancies are disclosed, Your Company agrees to pay Gerdes for the costs associated with the audit as well as the license fees for the additional Authorized Users. In no event shall audits be made more frequently than semi-annually unless the immediately preceding audit disclosed a material discrepancy.
We highly recommend that regularly check this web site for updates or upgrades. Customer Services Your PrimuX ISDN adapter is very easy to install and use. This manual should contain all information you need. As every PC is different, it is always possible that problems occur that are due to specific configurations of your PC.
The driver software for the PrimuX adapters can be used on Windows XP, Windows Server 2003, Windows 7, 8, 8.1, 2008 Server and 2012 Server. Linux The driver software for the PrimuX adapters can be used with a Linux kernel version 2.4.x (2.4.10 or higher) or 2.6.x and 3.x. The CAPICFG TRACER tools need the GTK libraries 1.2...
Page 11
• In the GTK based installation program simply click Begin Install. The driver and utilities will be installed, compiled and loaded As the PrimuX drivers are not licensed under the GPL, recent Linux kernels may show a warning message (tainted kernel) when loading the drivers. You can safely ignore this message, though.
This command loads the current configuration from the driver. CAPICFG will query you to save your changes before deleting the current configuration. Open remote configuration This command opens a connection to a PrimuX driver loaded on another PC and loads its configuration. On the other PC the RMTCAPI daemon has to be started for this to work.
Page 13
Please input the IP address of the remote PC and the port used by the RMTCAPI daemon. Then click on Ok. Open This command loads a previously saved configuration from disk. CAPICFG will query you to save your changes before deleting the current configuration. Save This command saves the current configuration to disk.
Page 14
Copy selected data to the clipboard and delete it from the configuration. Copy Copy selected data to the clipboard. Paste Insert clipboard contents into the configuration. Delete Delete selected data. The 'Insert' menu CAPI Service The CAPI service can be added only once. It enables access to the ISDN adapters using the CAPI 2.0 (and CAPI 1.1) interface.
Page 15
The 'View' menu Toolbar Toggle the toolbar display. Statusbar Toggle the status bar display. Advanced Toggle availability of the advanced settings page. This page shows some technical settings that you can modify on your own risk... The 'Help' menu Content Open the contents page of the online help.
Page 16
CAPI Service These pages show information about the features supported by the CAPI service. You can use this list to check if the driver supports specific features some applications require. General This page shows the manufacturer data, version and revision information and an optional serial number the adapter reports to applications.
Page 17
RAS service On this page you will find the number of channels available for internet dial up connections. Adapter settings On this page you will find some general information about the selected adapter. Some adapter types (i.e. adapters connected to the serial port) need additional settings. These settings will be shown on this page, too.
Page 18
Line type Some technical data about the kind of line this port can be connected to. Switch Type You can get information about the switch and interface type from your phone provider. As most countries today use the ETSI-DSS1 standard the default setting should be a good start.
Page 19
same length and the lowest extension has to be numerically smaller than the highest extension. Depending on the port it may be necessary to add a trunk number to both numbers. Advanced The advanced settings are quite technical and require some basic knowledge of ISDN hardware. Adapters for the S0 bus offer the following advanced settings: Direct Dial In (NT2) If you set this to Yes the driver will automatically generate a SETUP ACK message on incomplete numbers.
Page 20
Group). The Hunt Group setting makes sense when a PBX can sense a deactivated line and will automatically distribute inbound calls only to active lines. Operating Mode [only available on adapters with NT mode support] Here you can select if the port should be used as terminal equipment (setting TE- Terminal Equipment (recommended)) or network termination.
Page 21
Service Settings You can specify what services should be available on each port. If you put a S2M and a S0 adapter into your PC you could configure the S2M for the CAPI service and the S0 adapter for the RAS service so it could be used for remote access. To configure a port for a specific service just drag the corresponding service symbol onto the port and drop it.
Page 22
Dial-In Numbers On this page you can select the range of extensions on which calls should be selected for this service. Please make sure that the specified lowest and highest extension lie inside the configured extension range for this port! CAPICFG...
ISDN over LAN The RMTCAPI daemon and the RMTCONFIG application enable you to share ISDN ad- apters over a TCP/IP network. To enable sharing you need to start the RMTCAPI daemon on those PCs with ISDN hardware. Other PCs can be set up to access the shared adapters by using RMTCONFIG.
When your local network is configured for DNS you can use DNS names instead of IP addresses when configuring shared ISDN access. CAPI Extensions The following chapters describe extensions to the CAPI standard the PrimuX drivers offer. These informations only will be useful for software developers. CAPI Extensions...
NT Mode The NT Mode can be enabled on supported adapters using CAPICFG. The port settings (Switch Type, TEI etc.) retain their meaning in NT Mode. This way it is possible to create PTMP and PTP ports. Simple When set to NT - Network Termination [simple] the driver will handle all NT peculiarities by itself so you can use standard applications.
Page 26
the connection by sending a DISCONNECT_REQ message it has to generate a busy tone by itself, too. Connections initiated by the application In this case almost no special handling is necessary. Only when the application terminates the connection it has to generate a busy tone for the terminal. Early B3 Connect In NT Mode the Early B3 Connect mechanism can be used after receiving a CONNECT_IND message.
Need help?
Do you have a question about the PrimuX and is the answer not in the manual?