Selection Principle
The following table describes the principles for selecting CPRI fiber optic cables.
Table 3-3 Principles for selecting CPRI fiber optic cables
Remote
Distance
≤ 100 m
(328.08 ft)
Longer than
100 m (328.08
ft) and shorter
than or equal
to 150 m
(492.12 ft)
Greater than
150 m (492.12
ft)
Pin Assignment
The following table describes the labels on breakout cables of a CPRI fiber optic cable and
recommended connections of the breakout cables.
Table 3-4 Labels on and recommended connections for the breakout cables of a CPRI fiber optic
cable
Label
1A
1B
2A
Issue 06 (2014-07-30)
Selection Principle
Multimode fiber optic cable
Multimode fiber optic cable
Recommended: single-mode
fiber optic cable (single-mode
pigtail and trunk single-mode
optical fiber)
Single-mode fiber optic cable
(single-mode pigtail and trunk
single-mode fiber optic cable)
Installation Position
Multimode Fiber
Optic Cable
Between a BBU
and an AAU
CPRI RX port on the
AAU
CPRI TX port on the
AAU
TX port on the BBU
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Remarks
Connects the BBU and AAU
When it connects two AAUs, the distance
between the two AAUs must be shorter than
or equal to 10 m (32.81 ft).
Connects the BBU and AAU
The single-mode pigtail on the AAU or
BBU side is connected to the trunk single-
mode fiber optic cable using the ODF.
Multimode Fiber
Optic Cable
Between Two
AAUs
CPRI RX port on
AAU 1
CPRI TX port on
AAU 1
CPRI TX port on
AAU 0
3 AAU Cables
Single-mode Pigtail
(Transited by the
ODF)
RX port on the BBU or
CPRI RX port on the
AAU
TX port on the BBU or
CPRI TX port on the
AAU