Accupulse Setup - Panasonic EYFLA4 Quick Manual

Table of Contents

Advertisement

AccuPulse HR Setup Instructions
Step 1
Select Tool & Initial Torque Setting
*Chart based on medium/hard joint type
Step 2
Flush Detection Level Adjustment
1. Reset Torque Stage to initial
setting from Step 1 #2
2. Adjust L mode from L1 to L2
3. Rundown Fastener & confirm
Bolt head is Flush by VISUAL
Check
4. If NOK increase L mode until
Flush by Visual Check
5. If OK proceed to step 3
1. Choose correct tool & fastener size
from chart
2. Set tool torque stage according to the
chart & put tool in L1 mode.
3. Rundown fastener & audit with
torque wrench
4. Adjust torque stage up or down to
achieve target torque
5. If unable to achieve target torque
proceed to step 2
Step 3
Set Final Torque Stage
1. Perform static audit on fastener
with rotary transducer or torque
wrench
2. Adjust target torque value until
target torque is achieved