6.4.4. Software Update

Before updating the software from the display, send an ZCS Azzurro Technical Support requesting the files
for updating the 3000SP inverter firmware. Proceed as follows:
1. Switch off the ZCS 3000SP inverter by disconnecting the AC power and turning off the batteries.
If Pylontech batteries are used, set the switches of each battery in the pack to 0.
If WeCo batteries are used, press the POWER button for 5 seconds until the RUN light switches off.
2. Remove the central cover at the bottom of the inverter by unscrewing the four star screws, making
sure to loosen the four cable glands (as shown in the figure).
3. Extract the microSD card from its slot (shown in the figure above) by pressing lightly on the card and
pulling it out of the inverter. Then insert it into the PC using the appropriate adapter.
4. Open the SD card drive and create a new folder with the name ES3000firmware, making sure to
match the lowercase and uppercase letters as indicated and checking that there are no spaces. Now
copy the files attached to the email into the ES3000firmware folder.
5. Extract the SD CARD from the PC using the "safely remove hardware" process.
User Manual 3000SP
Rev. 1.1 16/03/2021
Identification: MD-AL-GI-00
Rev. 1.1 of 16/03/2021 - Application: GID
Max. charge threshold (V)
Max. discharge current
Min. discharge voltage (V)
Min. voltage threshold
(3)
End-of-discharge V
End-of-charge V
Value of maximum voltage (charge)
Maximum discharge current in A
(A)
Minimum voltage value (protection)
Minimum voltage value (discharge)
Voltage with batteries charged to 0%
Voltage with batteries charged to
100%
61 / 121

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AZZURRO 3000SP and is the answer not in the manual?

Questions and answers

Table of Contents