3. Disassembly and Reassembly
3-8 Removing the Cooling fan
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing the range . Replace all panels before operating the range . Failure to do so
can result in death or electrical shock .
WARNING
EXPLOSION, FIRE, AND ASPHYXIATION HAZARD
Shut off the gas supply to the range before servicing. Check all gas lines and fittings for leaks before
operating the range . Replace all panels before operating the range . Failure to do so can result in death or
personal injury from explosion, fire, or asphyxiation .
CAUTION
When you work on the gas range, be careful when handling sheet metal parts . Sharp edges may be present,
and you can cut yourself if you are not careful .
Parts
COOLING
FAN
Explanation Photo
Cooling
Fan Bracket
Cooling Fan
23
Explanation
1 .
Follow the steps in 3-2
2 .
Disconnect 2 wire connectors from TCO .
3 .
Disconnect 1 wire connectors
from Cooling Fan .
4 .
Remove 1 screws from the Cooling Fan
Bracket and separate
Cooling Fan assembly .
5 .
Remove 2 screws from the Cooling Fan
and Bracket and separate
Cooling Fan .
Need help?
Do you have a question about the NX58M6850S Series and is the answer not in the manual?