GE IC3645SH7R354D2 Installation And Operation Manual page 18

Separately excited (sx) transistorized motor controllers for neighborhood electric vehicle application
Table of Contents

Advertisement

DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
Both the forward and reverse switches
-09
are closed at the same time.
MEMORY RECALL
NO
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
Accelerator pedal is depressed before
Traction
closing forward or reverse directional
Controller
switch.
•=Status code will disappear when
directional switch is closed or when
accelerator pedal is released.
Defective directional switch
•=Check forward or reverse switch to insure
closure when direction is selected.
Open circuit between directional switch(es)
and 12V positive or between directional
switch(es) and P4 or P5.
•=
Check all control wires and connections
shown in Trouble Shooting Diagram.
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
Start switch closed on power up after initial
-11
key switch closure.
MEMORY RECALL
NO
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
Traction
Start switch is mis-adjusted or defective.
•=
Input voltage at P3 should be less than
Controller
7.2V at key switch closure. Adjust or
replace accelerator unit to insure that the
voltage at P3 is less than 7.2V before
closing the start switch.
Short circuit between P15 and P3 in start switch
input circuit.
•=
Disconnect wire from P3. Check for short
circuit from this wire to 12V positive.
Resistance should be greater than 4.7K
ohms.
Defective control.
•=
Disconnect wire from P3. Measure voltage
from P3 to negative. Voltage should be
zero. If not, replace the control.
CORRECTIVE ACTIONS
CORRECTIVE ACTIONS
CAUSE OF STATUS INDICATION
This status code will be displayed when P4 and P5
are less than 7.2 volts, and P7 is less than 2.5 volts.
TROUBLE-SHOOTING DIAGRAM
KEY SWITCH *
DIRECTIONAL
SWITCH *
P1
P2 P3
+12V
PLUG (23 PIN)
P15 P14
P16
CAUSE OF STATUS INDICATION
This status code will be displayed when P3 is
greater than 7.2V when the key switch is closed.
TROUBLE-SHOOTING DIAGRAM
KEY SWITCH *
DIRECTIONAL
SWITCH *
P1
P2 P3
PLUG (23 PIN)
+12V
P15 P14
P16
P7 P9
Page 18
*
L
P4
P5
P21 P11 P10
P7 P9
P13 P8 P6
*
L
P4
P5
P21 P11 P10
P13 P8 P6