Dell PowerEdge 4100/180 and 4100/200 Systems Installation and Troubleshooting Guide
Table 3-1. System Messages
Cause
The battery on the sys-
tem board is dead.
The CMOS configura-
tion data is corrupted.
The installed diskette
drive type does not
match the diskette drive
type in CMOS.
A cable or connector
may be loose, or the
keyboard may be faulty.
One or more DIMMs
may be improperly
seated or faulty.
The diskette, CD, or
hard-disk drive may not
have a bootable operat-
ing system on it.
The microprocessor chip
on the system board may
be malfunctioning.
A chip on the system
board may be mal-
functioning.
The RTC on the system
board may be mal-
functioning.
Action
Replace the battery on the system board, and run the System
Setup program to restore the system configuration informa-
tion. See "Replacing the Battery" in Chapter 8 for details.
Run the System Setup program to restore the system configu-
ration information.
Run the System Setup program to correct the diskette drive
type.
Check the keyboard cable and connector for proper connec-
tion. If the problem persists, run the Keyboard Test Group in
the system diagnostics to determine whether the keyboard or
keyboard controller is faulty. See Chapter 5, "Running the
System Diagnostics."
Remove and reseat the DIMMs. See "Installing DIMMs" and
"Removing DIMMs" in Chapter 8.
Insert a diskette or CD with a bootable operating system, or
load a bootable operating system on the hard-disk drive. Run
the System Set Test Group to determine whether the micro-
processor chip is faulty. See Chapter 5, "Running the System
Diagnostics."
Run the System Set Test Group to determine whether the
microprocessor chip is faulty. See Chapter 5, "Running the
System Diagnostics."
Run the System Set Test Group to determine whether the sys-
tem timers are faulty. See Chapter 5, "Running the System
Diagnostics." A faulty chip on the system board usually
requires that you replace the system board.
Run the System Set Test Group to determine whether the RTC
on the system board is faulty. See Chapter 5, "Running the
System Diagnostics."