Dell™ PowerEdge™ 1550 and
PowerApp™ 120 Systems —
PERC 3/DC Cable Installation
This document provides updated information for installing the Dell PowerEdge Expandable RAID
Controller 3/Dual Channel (PERC 3/DC) in your Dell PowerEdge 1550 or PowerApp 120 system.
The PERC 3/DC kit included with your system contains two small computer system interface (SCSI)
cables that connect your PERC 3/DC card to the internal SCSI backplane board in your system. A
description of these cables and their application is provided in Table 1.
Table 1. Cable Description
Cable Length
Short cable
Long cable
To avoid interference with system components and operation, be sure to use the short SCSI cable
when installing the PERC 3/DC card in your PowerEdge 1550 or PowerApp 120 system.
Installing the PERC 3/DC Card in Your System
To install the PERC 3/DC card in a PowerEdge 1550 or PowerApp 120 system, perform the following
steps.
WARNING: Before you install the PERC 3/DC card, you must turn off the system and dis-
connect it from the electrical outlet. For more information, see "Safety First—For You and
Your Computer" in the System Information document that came with your system.
1.
Turn off the system, including any attached peripherals, and disconnect the system from the
electrical outlet.
www.dell.com
Application
PowerEdge 1550 systems and
PowerApp 120 systems
All other supported systems
support.dell.com
P/N 4E580 Rev. A00
February 2001
04E580 A00

Advertisement

loading

Summary of Contents for Dell PowerEdge 1550

  • Page 1 PERC 3/DC card in your PowerEdge 1550 or PowerApp 120 system. Installing the PERC 3/DC Card in Your System To install the PERC 3/DC card in a PowerEdge 1550 or PowerApp 120 system, perform the following steps.
  • Page 2 Prepare the PERC 3/DC card for installation, and open the system cover. For instructions, see your system’s Installation and Troubleshooting Guide. Disconnect the power supply cable from the system board. NOTE: Disconnecting the power supply cable will facilitate cable installation in step 9. Remove the SCSI backplane board from the chassis.
  • Page 3 Reproduction in any manner whatsoever without the written permission of Dell Computer Corporation is strictly forbidden. Trademarks used in this text: Dell, the DELL logo, PowerEdge, and PowerApp are trademarks of Dell Computer Corporation. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products.

This manual is also suitable for:

Powerapp 120