CIFS service disabled!
Data disk n x % rebuilt
Disk n is broken
This message appears only if you have
licensed CIFS. One of the following errors
causes CIFS service to fail:
The filer's /etc/passwd and /etc/group
files are missing. To learn how to cre-
ate a new filer, refer to the Dell
PowerVault 720N, 740N, and 760N
System Administrator and Command
Reference Guide .
The filer failed to register its WINS
host name and workgroup name with
the WINS server. Using the cifs
setup command, enter the host
name and workgroup name.
The WINS server has a problem.
Refer to the documentation for your
WINS server for information about
troubleshooting the server.
n —The RAID group disk number; x —
amount of data reconstruction completed.
This shows how much data reconstruction
has been completed on the spare disk
after the system entered degraded mode.
If an error occurs when the reconstruction
is in progress, the error message over-
rides this message.
Refer to the Dell PowerVault 720N, 740N,
and 760N System Administrator and
Command Reference Guide for informa-
tion about how to locate a disk based on
the RAID group disk number.
n —The RAID group disk number. The
solution depends on whether you have a
hot spare installed in the system. Refer to
the Dell PowerVault 720N, 740N, and 760N
System Administrator and
Command Reference Guide for informa-
tion about how to locate a disk based on
the RAID group disk number and how to
replace a faulty disk.
Troubleshooting the Filer Hardware