Petrol cold water high pressure cleaner (24 pages)
Summary of Contents for Spitwater SHW90
Page 1
PETROL HOT WATER HIGH PRESSURE CLEANER MODEL NO: SHW90 (SW21200PE) MADE IN AUSTRALIA SPITWATER AUSTRALIA PTY LTD 953 METRY STREET NORTH ALBURY NSW 2640 AUSTRALIA WARNING: Read and understand this instruction manual before operating this unit and retain for future reference.
Page 2
SPARE PARTS, ACCESSORIES AND AFTER SALES SERVICE Spitwater has an extensive range of spare parts and accessories to suit all your cleaning needs. For spare parts, accessories and service please contact 1800 SPITWATER (1800 774 892) and to view Spitwater's extensive range of high pressure cleaners online visit www.spitwater.com.au...
TECHNICAL DATA MODEL SW21200PE PRODUCT SHW90 #N/A UNIT PERFORMANCE FLOW RATE PRESSURE PRESSURE #N/A NOZZLE #N/A WATER TEMPERATURE #N/A °C WATER INLET PRESSURE MAX #N/A TEMP MAX #N/A °C ENGINE ENGINE MODEL HONDA GX630 TYPE PETROL SPEED 3570 #N/A #N/A...
DESCRIPTION OF SYMBOLS The following symbols are used throughout this instruction booklet in order to mark important paragraphs or sections that require particular attention. Their meaning is listed next to them for your attention. The following symbols are used on the unit in order to warn user of potential injury if not cautious. Their meaning is listed next to them for your attention.
Page 5
SAFETY LABELS, UNIT COMPONENTS FEATURES & CONTROLS • Always pay attention to the safety instructions provided on each label. Do not alter or remove safety labels PETROL TANK TEMPERATURE WATER INLET ADJUSTMENT CHEMICAL CONNECTOR TANK ISOLATOR SWITCH BURNER EMERGENCY ON / OFF STOP BUTTON DIESEL...
GENERAL SAFETY PRECAUTIONS 1. OBSERVE SAFETY INSTRUCTIONS • Make sure you have read and understood the whole instruction manual before installing, operating or carrying out any maintenance on this unit. • Warnings and serial label on the unit provide important directions and information on the safe use of the unit.
4. EXHAUST & FLUE GASES • Do not use combustion engine powered machines indoors unless adequate ventilation is assessed by national labor authorities. • Exhaust contains poisonous carbon monoxide gas that can build up to dangerous levels in closed areas. Breathing carbon monoxide can cause unconsciousness or death.
OPERATIONAL SAFETY PRECAUTIONS All health and safety regulations applicable to general safe work practices, as well as safe operation of equipment, as well as any specific standard for safe operation of high pressure cleaners according to local regulations must be followed. When operating this unit, 1.
Never exceed the maximum working temperature and pressure as indicated on the unit data plate and in this manual. • Only use this unit with cleaning chemicals recommended by Spitwater. The use of other cleaning agents or chemicals may adversely affect the safety of the unit. •...
5. When not in use the unit must be stored in a dry building where there is no possibility for the temperature to be at or below 0°C. If necessary to store the unit at or below 0°C contact your authorized Spitwater service agent for advice.
Page 11
2. Remove carton and carefully remove the unit from the pallet keeping it upright. Visually check for any damage, leaks or other issues. If any problem is found, contact your Spitwater agent immediately. 3. Identify the unit from the information on the serial label affixed to the unit.
8. NOZZLE ASSEMBLY Connect the high pressure nozzle (smaller hole) and the low pressure nozzle (larger hole) to the lance. Do not over tighten and make sure that the nozzle positions do not interchange during assembly. Add nozzle shield after nozzle assembly. Refer diagram below. 9.
Contact your Spitwater agent for advice and /or supply. • Make sure the water supply temperature and pressure meet the values specified in the technical data, then turn the water supply on. Visually check for leaks and contact your Spitwater service agent if found. •...
Page 14
12. FUELLING POINTS Remove the PETROL tank cap and fill the petrol tank with clean filtered petrol. ONLY USE CLEAN PETROL IN THIS UNIT, as using any other fuel will create a risk of explosion and damage to the unit. PETROL FUELLING POINT DIESEL FUELLING POINT Remove the DIESEL tank cap and fill the...
CHECK LIST” in the SERVICE / CARE section as a guide. If the unit is damaged or faulty in anyways, DO NOT use it and immediately contact your authorized Spitwater service agent for advice. TO START 1. Always wear appropriate Personal Protective Equipment.
TO USE PRESSURE ADJUSTMENT HIGH / LOW 1. Release the spray gun trigger lock. 1. To activate high pressure turn the lance handle clockwise and pull the trigger and to activate low 2. Pull the trigger on the spray gun and allow water to run through the system for a few pressure turn the lane handle anti-clockwise.
Page 17
2. Turn the temperature adjustment knob to achieve desire cleaning temperature. 4. Never allow sprayed detergent to dry on the cleaning surface, as this may damage the surface. 3. After hot water use, press burner stop button (0). This will turn OFF the hot water and change back TO STOP to cold water mode for cleaning.
Page 18
Turn the Isolator switch to OFF position. 5. If the unit is to be left unused for an extended period, be sure to clean the detergent line by running the water through it and dropping the detergent line into a container of clean water.
2. Carry out all regular maintenance and Spitwater recommends that all maintenance is inspections as listed in this manual using carried out by an authorized Spitwater service original Spitwater parts where required. agent using original Spitwater spare parts. 3. Always make sure before carrying out any...
● Clear fumes = ideal condition to run the unit. Check pump seals for any leak. Unusual noise from unit. STOP operting the unit, Unit is fit, proceed task Contact Spitwater service agent immediately Contact Spitwater service Do It Yourself, agent / Qualified person for...
Page 21
USAGE VS SERVICE FREQUENCY TABLE-A: Usage vs Service Frequency For more information on service intervals of the Honda petrol engine, refer manual Time interval for checks and replacement listed above are for units subjected to normal operating conditions. Should the unit be subjected to abnormal conditions (eg heavy use, dirty water, extreme temperatures or conditions etc) times should be reduced accordingly.
OIL CHECK POINTS ENGINE OIL CHECK PUMP OIL CHECK ENGINE OIL CHECK PUMP OIL CHECK Ensure the unit is on a flat surface. Ensure the unit is on a flat surface. Check the oil level in the pump using Remove the oil level dipstick and the dipstick or the sight glass on the wipe it clean.
TROUBLESHOOTING GUIDE If the fault cannot be identified or corrected using the below list (or remedy suggests contacting Spitwater service agent) stop using the unit immediately and contact your authorized Spitwater service agent to rectify. TROUBLESHOOTING GUIDE FAULT CAUSE REMEDY...
Need help?
Do you have a question about the SHW90 and is the answer not in the manual?
Questions and answers