Page 1
BMV 712 Smart Quick installation guide Battery safety warnings Working in the vicinity of a lead acid battery is dangerous. Batteries can generate explosive gases during operation. Never smoke or allow a spark or flame in the vicinity of a battery. Provide sufficient ventilation around the battery.
Page 2
BMV 712 Smart Quick installation guide Mounting option A Mounting option B Page 2 Rev: 00...
Page 3
BMV 712 Smart Quick installation guide BMV connections RJ12 LOAD BATTERY ONLY CHARGER Buzzer RJ12 Relay Shunt side view Shunt top view VE.Direct Head unit top view Head unit rear view LOAD BATTERY ONLY RJ12 CHARGER Battery negative connection System negative connection ...
Page 4
BMV 712 Smart Quick installation guide Monitoring voltage of a second battery Monitoring midpoint of a battery bank Connect the other power cable between the Connect the other power cable between the positive terminal of the second battery and the battery bank midpoint and the shunt B2 terminal ...