MOUNTING INSTRUCTIONS
Mount the cooker hood as shown in the pictures.
The cooker hood is heavy and in order to move it 2 persons are needed.
During the installation of the cooker hood, always wear protective handgloves to prevent injuries.
The pipe must be heat, flame and corrosionproof. The manufacturer strongly advises against the
use of reducers or pipes with different diameter to the hood outlet pipe, and pipes made of
flexible aluminium because performance is diminished and noise level increased.
The end part of the pipe, on the outside of the hole on the wall, must be of such a shape to
avoid rain, gusts of wind or other foreign bodies getting into the pipe. Should there be any doubt,
contact anyone specialising in the installation of gas or ventilation system and not to reduce air
flow.
BEFORE ELECTRICAL INSTALLATION
Before connection you must:
check that the electrical data indicated are in conformity with the main voltage and
■
frequency values of the building where the hood is to be installed;
check that the building is fitted with electric safety systems to protect against short circuits
■
and electric shock systems, according to the laws in force;
install an electric socket (or connection point) with a bipolar switch, which has contacts with
■
an opening of at least 3 mms;
if it is wished to install the hood with a plug, it is necessary that you have access to the
■
plug;
always turn off the main voltage supply by means of the bipolar switch before connecting
■
and switch on again only when connections have been completed, tested and are safe.
ELECTRICAL CONNECTION
WARNING
The electrical connection can only be carried out by qualified professional personnel, using
standard material and state of the art installation methods. The manufacturer declines any
responsibility for installations carried out by unskilled persons and for installations which are not
in conformity with the standard norms concerning electrical safety (both concerning methods
and materials).
ELECTRICAL TECHNICAL DATA
The electrical technical data are visible inside the hood after the removal of the grease filters.
CONNECTION TO THE POWER SUPPLY
The flexible feed cable supplied is already connected internally and emerges from the hood near
the air outlet duct.
It is possible to effect two types of electric installation:
fixed installation;
■
installation by means of plug on a socket.
■