15. Changing basic settings
i
The set values guarantee that the ACS 511 will
function perfectly. These parameters may only be
changed by an A/C service unit engineer and after
approval from the manufacturer.
!
Follow the additional ACS 511 menu prompting.
Param-
Actions
eter
P1
System pressure empty.
Absolute pressure value above which re-
covery begins.
P2
Pressure at end of recovery.
Absolute pressure value above which re-
covery ends.
P3
Vacuum test pressure.
Absolute pressure value after which the
vacuum test turns out to be negative.
T1
Vacuum pump oil change threshold.
Number of hours before a prompt to
change the vacuum pump oil appears on
the display.
T2
Time for automatic emptying.
Value in seconds for duration of automat-
ic emptying.
T3
Maximum time for recovery.
If this time is exceeded, the function is
aborted and the message "LONG EXTRAC-
TION TIME" appears on the display.
T4
Weight variation monitoring threshold
Time in seconds in which the weight (re-
covered quantity) must change during re-
covery, otherwise the operation is abort-
ed.
T5
Oil outlet time. Time in minutes for the oil
drainage duration.
T7
Specified time for vacuum. The mean time
recommended by car manufacturers is 20
minutes.
T8
Not used.
T9
Vacuum test duration.
Time for checking any pressure increase
after the vacuum function has been exe-
cuted.
T10
Recycling plus vacuum time.
Time in minutes for the duration of the re-
cycling plus vacuum function.
T13
Maximum time for the filling process.
If this time is exceeded, the function is
aborted and the message "FILLING IN-
COMPLETE" appears on the display.
T14
EV9 UV contrast medium open duration.
Time in seconds for which the solenoid
valve EV9 is open. Corresponds to the
time for which UV contrast medium is
added.
T15
Maximum time for the oil filling process.
If this time is exceeded, the function is
aborted and the message "HIGH OIL FILL -
ING TIME" appears on the display.
T16
Maximum time for the flushing process.
If this time is exceeded, the function is
ended and the process continues.
|
1 689 975 252
2019-05-15
1. Call up the start screen.
2. Press <3> and <Flush> simultaneously and release.
 The message
5599
3. Enter
4. Select the relevant parameter with o u and confirm
with E .
i
Return with <Stop>.
Default
Param-
Actions
eter
T20
Vacuum test time for flushing operation.
1700
Time in seconds for the vacuum test dura-
tion in the flushing function.
600
T21
EV7 oil outlet open duration.
Time in seconds for which the solenoid
valve EV7 remains open during the oil out-
let function.
300
W1
Combo filter replacement threshold.
Value in kilograms before a prompt to re-
place the combo filter appears on the dis-
50
play.
W6
Max. capacity of small bottle.
Value in grams that represents the maxi-
mum quantity for filling the small internal
60
refrigerant cylinder.
W8
Max. capacity of large bottle.
Value in grams that represents the maxi-
30
mum quantity for filling the large internal
refrigerant cylinder.
OUTOIL2
Maximum capacity of used oil bottle.
If this value is exceeded, the message
60
"USED OIL BOTTLE FULL, EMPTY CON-
TAINER" appears.
OUTOIL3
Not used
HOSE
Minimum time for cleaning the service
4
CLEAN-
hoses. This is the minimum value in sec-
ING TIME
onds for emptying the service hoses af-
ter filling.
20
CON-
Activates and deactivates the "Save data
TROL RE-
via ACUSB PC interface" function.
PORT
-
COMPEN-
Activates and deactivates the "Compen-
300
SATION
sation at 0 in filling phase" function (i.e.
AT 0
compensation is deactivated).
BYPASS
Activates and deactivates the "Bypass"
function. If this function is activated, the
10
MENU key skips the waiting times for the
main ACS 511 functions.
RENAULT
Mode required by Renault.
20
CONFIG
The times between two recoveries are ex-
tended. This mode can be activated or de-
activated as required
BACKUP
See section 16.2.
2
10
15
ENTER CODE 0000
and confirm with E .
Robert Bosch GmbH
is displayed.
Default
120
90
50
10000
8000
250
-
60
0 (off)
0 (off)
0 (off)
0 (off)
-