Error Codes
When you apply power to the fixture, it runs a calibration (homing) sequence and displays any
errors that it detects.
Example:
error in channel 1. When multiple errors are present they will cycle on the display
twice, and then the fixture will reset (restart). Any errors that remain after two reset
cycles are not correctable by reset alone and will require service. Please contact
support if detailed assistance is needed.
Animation
This message displays after the reset of the fixture if any of the following conditions exist:
the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
•
the stepper motor is defective or the related IC driver on the main PCB has failed
•
the Animation movement is not located in the default position after the reset
•
Blade Rot
This message displays after the reset of the fixture if any of the following conditions exist:
the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
•
the stepper motor is defective or the related IC driver on the main PCB has failed
•
the Blade rotation is not located in the default position after the reset
•
Color
This message displays after the reset of the fixture if any of the following conditions exist:
the fixture head's magnetic-indexing circuit malfunctions (optical or magnetic sensor
•
failure)
the stepper motor is defective or the related IC driver on the main PCB has failed
•
the Color wheel is not located in the default position after the reset
•
Focus
This message displays after the reset of the fixture if any of the following conditions exist:
the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
•
the stepper motor is defective or the related IC driver on the main PCB has failed
•
the Focus wheel is not located in the default position after the reset
•
Gobo 1
This message displays after the reset of the fixture if any of the following conditions exist:
the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
•
the stepper motor is defective or the related IC driver on the main PCB has failed
•
Gobo Wheel 1 is not located in the default position after the reset
•
24
When the display shows "Err Info: Pan Movement", it means there is an
SolaFrame Theatre User Manual
Need help?
Do you have a question about the HIGH END SYSTEMS SolaFrame Theatre and is the answer not in the manual?