Sanyo PLC-XE50A Service Manual page 56

Hide thumbs Also See for PLC-XE50A:
Table of Contents

Advertisement

Service Adjustment
Group/
Item Name
Item
Group 250 FAN Cntorol
0 FAN1 MIN ADJUST (DAC)
1 FAN1 MAX ADJUST (DAC)
2 FAN2 MIN ADJUST (DAC)
3 FAN2 MAX ADJUST (DAC)
4 FAN3 MIN ADJUST (DAC)
5 FAN3 MAX ADJUST (DAC)
6 Not used
7 Not used
Group 251
Not used
Group 252 Fan Option
0 HI-LAND SWITCH
1 SAFETY SWITCH
2 FAN MANUAL SWITCH
3 FAN1 MANUAL VOLTAGE
4 FAN2 MANUAL VOLTAGE
5 FAN3 MANUAL VOLTAGE
6 Not used
7 Stand Mode
Fan Offset Voltage Update In-
8
terval
Group 253 Fan Tem Error Setting (Memorized)
0 Not used
1 Not used
2 Not used
3 Not used
4 Not used
5 Temp A Warning (High)
6 Temp B Warning (High)
7 Temp C Warning (High)
8 Temp B-A Warning (High)
9 Temp C-A Warning (High)
10 Temp A Warning (Normal)
11 Temp B Warning (Normal)
12 Temp C Warning (Normal)
13 Temp B-A Warning (Normal)
14 Temp C-A Warning (Normal)
15 Temp A Warning Offset (Temp)
16 Temp B Warning Offset (Temp)
17 Temp C Warning Offset (Temp)
18 Temp B-A Warning Offset (Temp)
19 Temp C-A Warning Offset (Temp)
20 Temp A Warning Offset (Time)
21 Temp B Warning Offset (Time)
22 Temp C Warning Offset (Time)
23 Temp B-A Warning Offset (Time)
24 Temp C-A Warning Offset (Time)
25 Factory Mode
Function
DAC Output for Fan
Adjust the tolerance of DAC and Fan
Volage.
* Lamp mode is forced Eco
0: Normal, 1: Hi-Land, 2-4: Hi-Land
1-3
For test purpose
0: Auto, 1: Manual
Fan Voltage (unit : 0.1V)
Effective only when Fan Maual
switch is 1
Stand mode setting
0: Normal(Free) 1: Normal(Fixed)
2: Celling 3: Down 4: Up
filter clogged Fan Voltage Update
interval time ( sec.)
Temp. A to judge the Temp Error at
High (Room)
Temp. B to judge the Temp Error at
High (Panel)
Temp. C to judge the Temp Error at
High (Lamp)
Temp. B-A to judge the Temp Error at
High (Clogging Det.)
Temp. C-A to judge the Temp Error at
High (Clogging Det.)
Temp. A to judge the Temp Error at
Normal (Room)
Temp. B to judge the Temp Error at
Normal (Panel)
Temp. C to judge the Temp Error at
Normal (Lamp)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Offset of Temp Error (Temp.)
Error Setting Value is increased X°C at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Offset of Temp Error (Minutes)
Error Setting Value is increased X
minute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
For factor use
Initial
45
235
45
235
45
235
0
0
0
100
100
100
0
60
Normal
Ceiling
Down
Up
41
41
41
41
32
32
32
32
51
51
51
51
57
57
57
57
73
73
73
73
78
78
78
78
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
42
42
42
42
32
32
32
32
52
52
52
52
58
58
58
58
75
75
75
75
80
80
80
80
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
5
5
5
0
0
1
1
1
1
1
0
- 56 -
Range Note
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 5
0 - 6
0 - 3
0 - 255
0 - 255
0 - 255
0 - 4
1 - 600
Normal/Celling/Down/Up
30-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
30-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
30-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
30-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
30-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
30-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-100
HiLand : Normal/ Celling/Down/Up
Down
Normal
Up
Celling

Advertisement

Table of Contents
loading

Table of Contents