Safety Distance (S) - Miele DA 416-6 Operating And Installation Instructions

Table of Contents

Advertisement

a Extraction
b Recirculation
c Ventilation grille positioned at the top for recirculation
de (only d is required for recirculation mode rangehoods):The shaded area
represents the wall or ceiling area for the vent cut-out and for fitting the
connection socket. Recirculation mode rangehoods only require an electrical
connection socket.
Connection for air extraction  150 mm, or 125 mm with reducing collar.

Safety distance (S)

The minimum distances between the top of a cooktop (excluding trivets, dials -
depending on model) and the bottom of the rangehood are as follows, unless a
greater distance is specified by the manufacturer of your cooking appliance.
See also "Warning and Safety instructions".
Cooking appliance
Electric cooktop
Open electric grill
Deep fat fryer (electric)
Multi-burner gas cooktop with maximum 45.4 MJ/h
total output, with no burner having a greater output than
16.2 MJ/h.
Multi-burner gas cooktop with total output greater than
45.4 MJ/h, or a gas cooktop including a single burner
with an output greater than 16.2 MJ/h.
Single gas cooktop with a maximum output of 21.6
MJ/h.
Single gas cooktop with a maximum output greater
than 21.6 MJ/h.
Installation
Minimum distance S
600 mm
650 mm
650 mm
650 mm
760 mm
650 mm
760 mm
27