Operations Guide - DOC. 8137
Professional Audio Distribution Processor
NOTE: If rack mounting is not required, rubber feet are provided for table-top
mounting or stacking. Apply the feet near the corner edges on the underside of the
unit.
NOTE: Reliable grounding of rack mounted equipment should be maintained.
Particular attention should be given to supply connections other than direct
connections to the branch circuit. (e.g., use of power strips).
Two "ears" are provided with the CNX-PAD8 so that the unit can be rack mounted.
These ears must be installed prior to mounting. Complete the procedure below to
attach ears to CNX-PAD8.
1. There are 16 screws (#6-32 x 0.375" LG) that secure the CNX-PAD8
top cover. Remove the three screws closest to the front panel from one
side of the unit.
2. Position a rack ear so that its drilled holes align with the holes vacated
by the screws in step 1.
3. Secure the ear to the CNX-PAD8 with three screws from step 1, as
shown below.
Ear Attachment for Rack Mounting
4. Repeat procedure (steps 1 through 3) to attach ear to other (right) side.
5. If the rear panel of the CNX-PAD8 is accessible when mounted in the
rack, install the CNX-PAD8. If the rear panel is NOT accessible,
perform the hookup procedure before rack installation.

Hookup

Refer to the two hookup diagrams after this paragraph. The first diagram illustrates
the connections to a SmarTouch STS (ST-CP). The second diagram shows
connections to the Cresnet system. Other than making the power connection last,
complete the connections in any order, regardless of whether the CNX-PAD8 is part
of a SmarTouch STS (ST-CP) or a Cresnet system. RCA cables are not supplied.
NOTE: Review Network Modular Cable Requirements (latest revision of Doc.
5682) when making connections to the Cresnet RJ11 modular jacks.
NOTE: Review the Network Interconnection Diagram (latest revision of Doc.
5411) when making 4-wire connections.