Do you have a question about the UHE-CMTF91 and is the answer not in the manual?
Questions and answers
Melanie Turner
January 18, 2025
How do I get an instruction manual and where can I get cartridges.
1 comments:
Mr. Anderson
February 4, 2025
To obtain an instruction manual for the HoMedics UHE-CMTF91, visit www.homedics.com (for the USA) or www.homedics.ca (for Canada). To acquire cartridges or other accessories, you may also contact HoMedics customer service at 1-800-466-3342 (USA) or 1-888-225-7378 (Canada) during their operating hours.
This answer is automatically generated
Annie Parnell
January 29, 2025
Will not work no buttons will work
1 comments:
Mr. Anderson
February 10, 2025
The HoMedics UHE-CMTF91 may not be working and the buttons may not be responding due to the following possible causes:
1. Power Issue – The device may not be plugged in properly. Solution: Ensure the humidifier is connected to a working power outlet. 2. Power Supply Problem – There may be an issue with the circuit or fuse. Solution: Check the circuit breakers, fuses, or try a different outlet. 3. Low Water Level – The water level might be too low for the unit to function. Solution: Refill the water tank. 4. Dirty Transducer/Membrane – The ultrasonic transducer or membrane may require cleaning. Solution: Follow the cleaning instructions provided in the manual. 5. Incorrect Humidistat Setting – The humidistat may be set lower than the ambient humidity. Solution: Adjust the humidistat to a higher humidity level or set it to continuous mode. 6. Clogged Output Valve – The output valve may need cleaning. Solution: Follow the cleaning steps in the manual.
If the issue persists after checking these points, further troubleshooting may be needed.
This answer is automatically generated
Warren Duncan
February 11, 2025
Hi. I have the CMT F91. Lights are on, plenty of water in tank but no mist comes out.
1 comments:
Mr. Anderson
February 12, 2025
If your HoMedics UHE-CMTF91 humidifier is not producing mist despite having water and lights on, consider these possible reasons:
1. Empty or Incorrectly Seated Water Tank – Ensure the tank is filled with water and properly placed on the base. 2. Mineral Buildup – If the unit has been used without cleaning, mineral deposits may block the ultrasonic transducer. Clean the unit according to the manual. 3. Demineralization Cartridge Issue – If using a demineralization cartridge, check if it needs replacement, as an old or clogged cartridge can affect mist production. 4. Wrong Mist Level Setting – Ensure the mist level is not set too low. 5. Room Humidity Levels – If the room is already humid, the unit may produce less mist. 6. Blocked Mist Outlet – Check for any obstructions in the mist outlet. 7. Internal Malfunction – If none of the above solutions work, the unit may need professional servicing.
Try troubleshooting these issues to restore mist production.
Need help?
Do you have a question about the UHE-CMTF91 and is the answer not in the manual?
Questions and answers
How do I get an instruction manual and where can I get cartridges.
To obtain an instruction manual for the HoMedics UHE-CMTF91, visit www.homedics.com (for the USA) or www.homedics.ca (for Canada). To acquire cartridges or other accessories, you may also contact HoMedics customer service at 1-800-466-3342 (USA) or 1-888-225-7378 (Canada) during their operating hours.
This answer is automatically generated
Will not work no buttons will work
The HoMedics UHE-CMTF91 may not be working and the buttons may not be responding due to the following possible causes:
1. Power Issue – The device may not be plugged in properly. Solution: Ensure the humidifier is connected to a working power outlet.
2. Power Supply Problem – There may be an issue with the circuit or fuse. Solution: Check the circuit breakers, fuses, or try a different outlet.
3. Low Water Level – The water level might be too low for the unit to function. Solution: Refill the water tank.
4. Dirty Transducer/Membrane – The ultrasonic transducer or membrane may require cleaning. Solution: Follow the cleaning instructions provided in the manual.
5. Incorrect Humidistat Setting – The humidistat may be set lower than the ambient humidity. Solution: Adjust the humidistat to a higher humidity level or set it to continuous mode.
6. Clogged Output Valve – The output valve may need cleaning. Solution: Follow the cleaning steps in the manual.
If the issue persists after checking these points, further troubleshooting may be needed.
This answer is automatically generated
Hi. I have the CMT F91. Lights are on, plenty of water in tank but no mist comes out.
If your HoMedics UHE-CMTF91 humidifier is not producing mist despite having water and lights on, consider these possible reasons:
1. Empty or Incorrectly Seated Water Tank – Ensure the tank is filled with water and properly placed on the base.
2. Mineral Buildup – If the unit has been used without cleaning, mineral deposits may block the ultrasonic transducer. Clean the unit according to the manual.
3. Demineralization Cartridge Issue – If using a demineralization cartridge, check if it needs replacement, as an old or clogged cartridge can affect mist production.
4. Wrong Mist Level Setting – Ensure the mist level is not set too low.
5. Room Humidity Levels – If the room is already humid, the unit may produce less mist.
6. Blocked Mist Outlet – Check for any obstructions in the mist outlet.
7. Internal Malfunction – If none of the above solutions work, the unit may need professional servicing.
Try troubleshooting these issues to restore mist production.
This answer is automatically generated