GE
Lighting
Evolve
Modular Fixtures - Small & Medium (EASM & EAMM)
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Save these instructions for future use.
Risk of electrical shock. Disconnect power before servicing
or installing product.
Risk of injury or damage. Unit will fall if not installed
properly. Follow installation instructions.
Risk of injury. Wear safety glasses and gloves during
installation and servicing.
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This Class [A] RFLD complies with the Canadian standard ICES-003.
Ce DEFR de la classe [ A ] est conforme à la NMB-003 du Canada.
Note: This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area
is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
imagination at work
LED Area Light
WARNING
WARNING
CAUTION
• This luminaire is designed for outdoor lighting service,
and should not be used in areas of limited ventilation,
or in high ambient temperatures.
• Best results will be obtained if installed and maintained
according to the following recommendations.
• Luminaire is designed to operate in ambient
temperatures ranging from -40°C to 50°C and to be
mounted horizontally to a vertical pole with LEDs
facing down, as shown.
SPECIFICATIONS
• Weight: Maximum weight <50 lbs (22.68 kg)
• EPA: 1.35 sq ft max (0.13 sq M) (Calculated using
1.30 Cd X Total Area of 1.04 ft
• IP Rating: Optical 65, Standard Electrical Enclosure:
UL 1598 Wet Location Rated
Installation Guide
GEH-6006A
)
2

Advertisement

Table of Contents
loading

Summary of Contents for GE Evolve EASM

  • Page 1 Installation Guide GEH-6006A Lighting Evolve LED Area Light ™ Modular Fixtures - Small & Medium (EASM & EAMM) BEFORE YOU BEGIN Read these instructions completely and carefully. Save these instructions for future use. WARNING Risk of electrical shock. Disconnect power before servicing or installing product.
  • Page 2 UNPACKING • Place fixture against pole • Install 3/8 bolt, lock washer and washer in top as shown and tighten into nut plate • This luminaire has been properly packed so that no • Open arm door and install 3/8 bolt, lock washer and parts should have been damaged during transit.
  • Page 3 3c Square Pole Architectural Arm Mounting FIXTURE ARM TO ARM ADAPTER This luminaire has been configured the same as 3b Torque Top Bolt to 25 - 32 ft-lbs. and an adapter plate has been included to mount to (34-43 N-m) a square pole.
  • Page 4: Maintenance & Cleaning

    (1 - 888 - 69 - 43 - 533) GE Lighting is a subsidiary of the General Electric Company. Evolve and the GE brand and logo are trademarks of the General Electric Company. © 2013 GE Lighting. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
  • Page 5: Guide D'installation

    Guide d’Installation GEH-6006A Lighting Lampadaire à DEL Evolve ™ Systèmes d’installation Modulaires – Petit et Moyen (EASM & EAMM) AVANT DE COMMENCER ARRÊT Lisez attentivement toutes ces instructions. Conservez ces instructions pour référence future. AVERTISSEMENT Risque de choc électrique. Déconnectez l’alimentation électrique avant d’installer ou réparer ce produit.
  • Page 6 DÉBALLAGE • Placer le gabarit contre le poteau • Installer la vis de 3/8, la rondelle anti-retour et la rondelle supérieure comme indiqué et serrer contre la plaque de l’écrou. • Ce lampadaire et été emballé pour qu’aucune pièce ne soit •...
  • Page 7 3c Installation par support sur poteau à section GABARIT ET SUPPORT INTERMÉDIAIRE carrée Serrer la vis du haut à 25 - 32 ft-lbs. (34-43 N-m) Ce lampadaire a été configuré de la même manière que 3b et une plaque intermédiaire a été incluse pour installation sur poteau à...
  • Page 8: Entretien / Nettoyage

    (1 - 888 - 69 - 43 - 533) GE Lighting est une filiale de la General Electric Company. Evolve ainsi que la marque et le logo GE sont des marques commerciales déposées de la General Electric Company. © 2013 GE Lighting. Les informations fournies ici sont susceptibles de changer sans préavis. Toutes les données sont des valeurs de conception ou caractéristiques lors de leur mesure en conditions de laboratoire.
  • Page 9: Guía De Instalación

    Guía de instalación GEH-6006A Lighting Lámpara de LEDs para áreas Evolve ™ Lámparas modulares - pequeñas y medianas (EASM y EAMM) ANTES DE COMENZAR Lea estas instrucciones completamente y cuidadosamente. Guarde estas instrucciones para uso futuro. ADVERTENCIA Riesgo de descarga eléctrica. Desconecte la energía antes de suministrar servicio de mantenimiento o instalar el producto.
  • Page 10: Montaje

    DESEMPAQUE • Coloque la lámpara contra el poste • Instale el perno de 3/8, la arandela de seguridad y la arandela encima según se muestra, y apriete en la tuerca tipo placa • Esta lámpara ha sido empacada apropiadamente de modo •...
  • Page 11 3c Montaje con brazo arquitectónico en poste BRAZO DE LÁMPARA A PLACA ADAPTADORA cuadrado Apriete el perno superior hasta 25 a 32 lbs-pie. Esta lámpara tiene la misma configuración del montaje 3b y se (34 a 43 N-m) incluye una placa adaptadora para montaje en poste cuadrado. El patrón de orificios en el poste cuadrado deberá...
  • Page 12: Mantenimiento / Limpieza

    (1 - 888 - 69 - 43 - 533) GE Lighting es una filial de General Electric Company. Evolve y la marca y logo GE son marcas registradas de General Electric Company. © 2013 GE Lighting. La información suministrada está sujeta a cambios sin aviso previo. Todos los valores son valores típicos o de diseño, medidos en condiciones de laboratorio.

This manual is also suitable for:

Evolve eamm

Table of Contents