Summary of Contents for Vinten RADAMEC Fusion FH-100
Page 1
Vinten RADAMEC Robotic Camera Control Systems BROADCAST ROBOTICS FH-100 Robotic and Manual Pan & Tilt Head Operators Guide V3979-4980 Issue 3.0...
Page 2
Fusion FH-100 Robotic and Manual Pan & Tilt Head Operators Guide Publication Part No. V3979-4980 Issue 3.0...
Page 3
Vitec Group plc. Trademarks Vinten Radamec® and Vinten® are registered trademarks of the Vitec Group plc. Important information about this document Information contained in this document is subject to change.
английски език, а след това - преведени на други езици. Ако ezen utasításokat, kérjük, vegye fel a kapcsolatot a Vintennel не разбирате тези езици, свържете се с Vinten или с Вашия vagy a helyi képviselettel, és igényelje az eredeti utasítások дистрибутор, за...
Page 7
Disposing of old electronic equipment This symbol on the product or on its packaging indicates that this product must not be treated as household waste (applicable in the European Union and European countries with separate collection systems). It shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.
Contact Camera manual should be read in conjunction with Operating Guides for Dynamics Ltd or your local distributor to arrange the Fusion Pedestal, Fusion Height Drive and the Vinten servicing of this product. Radamec Controller when accompanying the installation of the Connections Fusion FHR-120 Robotic Head.
Page 9
Safety when working with Robotic equipment Safe working environment In normal operation, remote controlled Heads and Pedestals can move suddenly and without warning. Since audible warnings are not suitable for use within the studio environment, it is recommended that only trained personnel be allowed to work in the active areas where remote controlled Heads and Pedestals are located.
Operating Temperature .......... 0° C to 50° C Motor noise ..............Minimal Performance IMPORTANT NOTE: Technical data is subject to change without notice. Vinten Radamec reserves the right, without Tilt range ................±90° notice, to make changes in equipment design or performance Pan range ................359°...
The Head is supplied with standard accessories (Figure 1) including four fixing bolts and washers used when mounting the Head onto a tripod or pedestal mounting plate, a Vinten spanner and two telescopic pan bars for use when the Head is operated manually.
Mounting the head The Head has a standard Vinten four-hole mounting plate with a Quickfix base. The Head can be mounted onto a pedestal, typically the Fusion FP-188 pedestal, or onto a Vinten Heavy-duty tripod. CAUTION! Hold a fixing bolt in position through the mounting plate and ensure that the threaded end does not project more than 12 mm (15/32 in.) above the mounting plate face.
Page 16
Mounting the camera and payload Warning! Do not exceed maximum total payload 55 kg weight of 55 kg (121 lb) 121 lbs Fitting the camera The Head is designed to allow the camera and payload to swing about its own centre of gravity (C of G), as opposed to balancing with the use of springs or cams.
USB connection The Vinten Radamec Fusion Setup & Test software tool, called Vincon, is used to configure and set the Pan and Tilt limits of the Head. The software tool is also used by Service Personnel for diagnostic purposes. The software is installed onto a laptop or server/PC (usually running the Control software).
Page 18
Zoom/focus control input port on the Hand Control Interface unit. The unit is also supplied with the appropriate cables for connection to the pan bar hand-controls and camera lens. Figure 3 shows the connection between the Vinten Radamec Fusion Hand Control Interface and the Head. Figure 3 Fusion Hand Control Interface to Head Lens ports connection...
EPL connection to the Head is supplied by the EPL Out port on the Height Drive. The EPL In port connects to the Vinten Radamec Control Panel via the EPL Node. The Height Drive is supplied with a Head Communication cable that can be used to connect the Height Drive to the Head.
Head EPL port Head Communication cable Head Power Output socket Figure 5 Fusion Height Drive to Head Power & EPL Connections Balancing the Head and payload Ensure that the Head and camera cradle are level before balancing. When the Head is correctly balanced, the robotic drives will need the minimum amount of even effort to move the Head.
Page 21
Setting fore and aft balance When positioning the payload it is important to be aware of the potential danger of an unbalanced payload falling away suddenly. Always be prepared for this by maintaining a firm hold on the payload until the balance has been set correctly.
Before the limits can be set the Vinten Radamec Fusion Configuration software tool must be installed onto either a laptop for localized use within the studio or onto a PC or server, typically also running the Vinten Radamec Controller software.
Click SET PAN,TILT, X/Y AND HEIGHT LIMITS to set the limits for the pan and tilt axes. The Set pan, tilt & height limits dialog box appears as shown in Figure 7. Figure 6 Vinten Fusion Robot Control window (a) Robot Type section (b) Machine Version section (c) Zero Pan and Tilt button...
Figure 8 Angles of travel on the pan and tilt axes When done, click Apply and then OK to close the dialog box. Click OK to close the Vinten Fusion Robot Control window (Figure 6). Switch OFF the power to the Head.
Page 25
From the Control Panel, carefully drive the Head to its limits in both pan and tilt axes using the joystick to determine if the limits have been correctly set. Warning! Closely observe the camera movement while checking the software axis limits to avoid potential personal injury or damage to the equipment.
Operating instructions Powering up Warning! Ensure that all personnel and hazards are clear of Robotic equipment before switching the power ON. When the system is ready, ensure that all external cable connections are complete and the tilt lock is disengaged before switching the power ON. The Head should not move when power is switched ON, but zoom and focus will take up demanded positions on analogue lenses.
‘man’ will automatically rotate counter-clockwise to the ‘auto’ setting. To select robotic mode from a Vinten Radamec Control Panel: When a Head is set to manual operation, the Camera button on the Control Panel appears grey in colour. To bring the camera online, it must be enabled from the Control Panel before the camera can be controlled.
Zero Pan Pan right Pan left Move joystick to the Move joystick to the right to pan right. left to pan left. Figure 10 Controlling pan movements using a joystick Move joystick Move joystick forward to tilt the backward to tilt the camera downward.
Operating the Head in Manual mode Warning! The FH-100 Head can be used remotely from a Control Panel. Ensure that the Control Panel Operator does not attempt to select the camera whilst a Camera Operator is operating the Head manually. The Head can be operated manually by a camera operator using the bars to control the pan and tilt movements.
Adjusting the pan and tilt drag Both the pan and tilt mechanisms on the Head incorporate the patented Vinten lubricated friction (LF) system to ensure smooth movement of the camera about these axes and are fitted with dials to adjust the drag setting.
Maintenance Warning! To reduce the risk of electric shock, do not remove the cover. No user-serviceable parts inside. Refer to qualified service personnel. Routine checks During use, check the following: • Check the balance of the head. Re-balance as necessary. •...
Figure 14 Fuse compartment Adjusting the drag control dials The pan and tilt drag control dials may require adjustment after prolonged use. These adjustments must be carried out by competent persons. Contact Vinten Radamec for servicing the FH-100 pan & tilt Head.
Troubleshooting Fault Check Read Power supplied but the Check that the camera cradle tilt lock is Locking the camera cradle camera cradle is not moving. disengaged. Head not operating. Check that the power switch is ON. Powering up Ensure that the power and EPL cables Power and EPL are connected and secure.
Vinten Radamec Canon analogue Hand Control Interface, analogue servo lens ....V4050-0001 Vinten Radamec Canon digital Hand Control Interface, digital servo lens ....V4050-0002 Vinten Radamec Fujinon analogue Hand Control Interface, analogue servo lens .