Error Causes And Elimination; Maintenance; General Information - Bosch Rexroth IndraControl VSP 3 Series Instructions Manual

Table of Contents

Advertisement

DOK-SUPPL*-VSP*XX.3***-IT01-EN-P
Rexroth IndraControl VSP xx.3 Panel PC
13

Error Causes and Elimination

The error display on the front panel is described in
Display" on page
30.
Error
No image visible.
Wrong display resolution.
Touch screen functionality is not
available.
External displays do not show an
image.
After the new cards have been
plugged in, the card functions are
not available.
Fig.13-1: Error causes and error elimination
14

Maintenance

14.1

General Information

NOTICE
The IP degree of protection must be ensured during maintenance!
NOTICE
Comply with all ESD protective measures while working with modules and components!
Avoid electrostatic discharges!
chapter 12.2 "Operating and Error
Elimination
● Connect the voltage supply, check X10 connec‐
tion.
● Set the correct display resolution in the graphics
driver.
● Restart the panel PC.
● Recalibrate the touch screen.
● Check the connections.
● Shut down the panel PC, wait until the "Vin" LED
is cleared completely, restart the panel PC.
● Plug the card correctly into the PCI slot.
● Install the driver software of the card.
● Remove IRQ (Interrupt) conflicts with other PC
hardware components.
● Install the software of the card.
Loss of IP degree of protection due to incorrect
maintenance.
Damages to the device due to electrostatic dis‐
charges!