Download Print this page

Geisinger GBTVA-01 Instruction Manual page 4

Group head thermometer for e61 brew groups

Advertisement

Available languages

Available languages

(The difficult opening of the battery cover is not
a defect)
2.
Insert a LR44 battery with the + side up.
3.
Put the battery compartment cover back on.
Battery take-back
Batteries must not be disposed of with household
waste.
The consumer is legally obliged to return batteries
after use, e.g. at public collection points or where
such batteries are sold.
Batteries containing pollutants are marked with
the symbol „crossed out garbage can" and one of
the chemical symbols.
Battery notes
Batteries do not belong in the hands of children.
Never leave batteries lying around; there is a risk
of them being swallowed by children or pets
Batteries must never be short-circuited, disas-
sembled or thrown into fire. There is a risk of
explosion!
Leaking or damaged batteries can cause acid
burns on contact with the skin, so use suitable
protective gloves in this case.
When changing the batteries, only identical batte-
ries may be used.
Make sure that the polarity is correct when inser-
ting the battery.
If the device is not going to be used for a long
time (e.g. storage), remove the inserted battery to
avoid damage from leaking batteries.
disposal
Electronic devices are recyclable and do not belong in
the household waste. At the end of its service life, dis-
pose of the product in accordance with the applicable
statutory provisions. Remove any inserted batteries and
dispose of them separately from the product.
6. calibration (only GBTVA-01)
1.
The thermometer is only suitable for calibration in
a slush ice solution (60% crushed ice and 40% tap
water). Do not try to calibrate in any other way.
2.
Press the CAL button for 2 seconds.
3.
The display remains blank for 2 seconds.
4.
0.00 ° C or 32.0 ° F are displayed.
5.
The thermometer is now calibrated.
Note: To avoid accidental recalibration, this function
is only enabled at a water temperature of 30 to 34 ° F.
ERR appears for 2 seconds if the water is not within this
range.
7. Technical specifications GBTVA-01
Measuring range:
Display size:
Battery:
Unit of measurement ° F / ° C
Auto-off:
Housing material:
Technical specifications GBTVAQ-01
Measuring range:
Display size:
Battery:
Unit of measurement ° F / ° C
Auto-off:
Housing material:
Geisinger - Espresso in Perfektion
Bernd Geisinger
Schloßbühl 12
88348 Bad Saulgau
Tel.: 07583/941063
Email: info@geisinger.eu
www.geisinger.eu
-20 bis + 230 ° C
2,2 B x 1,3 H (cm)
1 LR44 enthalten
nach 10 Minuten
304 Edelstahlgehäuse / ABS
-40 bis + 200 ° C
2,5 B x 1,5 H (cm)
1 LR44 enthalten
nach 15 Minuten
Edelstahlgehäuse / ABS

Advertisement

loading
Need help?

Need help?

Do you have a question about the GBTVA-01 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Gbtvaq-01