Status bar

Tab.10: Status bar
LED
Green steady light
Red static
Yellow static
Yellow flashing
Red, yellow and
green are flashing
Red, yellow, green
static
Yellow off
Meaning
Tightening case evaluation:
OK
Tightening case evaluation:
NOK
Ready for operation
The check interval defined
by the user has elapsed.
System error
System boot
Not ready or in sequence
test
Bosch Rexroth AG
9
Maintenance and repair
9.1

Cleaning and care

CAUTION
Direct contact with the detergent!
Direct skin or eye contact with the detergent
as well as swallowing or inhaling the detergent
may cause injuries.
Avoid direct physical contact with the
detergent.
Observe the instructions for use and first
aid in the "Technical safety sheet" as well as
in the "Safety data sheet" of the detergent
manufacturer.
NOTICE
Penetrating dirt or liquids!
Failures may occur. Safe function of the
product is no longer ensured.
Always provide for absolute cleanliness
when working with the product.
For cleaning ErgoSpin/CC-ErgoSpin hand-
held nutrunners and their components, use
the LOCTITE® 7063™ detergent, see the
manufacturer's information below.
Manufac-
Henkel AG & Co. KGaA
turer:
Henkelstr. 67
40191 Düsseldorf
Germany