Return to Library
2
ALARM LIST - VTC-200/300 (MAZATROL FUSION 640M)
If an alarm listed below occurs, it can be cleared by pressing
cause of alarm.
Alarm No.
Alarm Name
(SQ Coil No.)
200
HYDRAULIC UNIT
(F0)
PRESSURE DOWN
202
AIR PRESSURE
(F2)
DOWN
203
SPINDLE OIL
(F3)
PRESSURE DOWN
204
SPINDLE OIL LOW
(F4)
206
SPINDLE LUB.
(F6)
CHILLER MALF.
207
IRREGULAR
(F7)
SLIDEWAY OIL
PRESSURE
208
SLIDEWAY OIL LOW
(F8)
209
SLIDEWAY OIL
(F9)
MALFUNCTION
211
SPINDLE
(F11)
CONTROLLER
MALFUNCTION
212
MAGAZINE DRUM
(F12)
MALFUNCTION
214
ILLEGAL TOOL
(F14)
DESIGNATED
217
THERMAL TRIP
(F17)
218
CONVEYOR THERMAL
(F18)
TRIP
219
MAIN TRANSFORMER
(F19)
OVERHEAT
222
AFC OVERLOAD
(F22)
223
TOOL MEAS. UNIT
(F23)
NOT IN POS
Description
Low hydraulic pressure state has continued
for more than 2 seconds.
Low pressure for spindle lubrication
Low pressure of the spindle lubrication oil
(pressure switch)
Low spindle lubricating oil level
Alarm with the spindle lubricating oil chiller
unit.
Low slideway lubricating oil pressure
Low level of lubrication oil in the centralized
lubrication unit tank
Alarm with the centralized lubrication unit
(for the pressure error of the centralized
lubrication unit)
Alarm with the spindle controller
Alarm with the magazine controller
Tool with tool data specified as invalid is
commanded.
A thermal relay of auxiliary equipment motor
is tripped.
The circuit protector in the 100 V line is
tripped.
The thermal relay of chip conveyor or
conveyor drive motor is tripped.
The main transformer is exceeding 120°C
(248°F).
Spindle load cannot be lowered even when
an override value is lowered using the AFC
function.
An attempt is made to execute semi-
automatic tool length measurement while
the tool length measurement base is not in
place.
2-1
(clear) or
(reset) key after eliminating the
Machine Status
Feed hold
Spindle stop
Only display of message
Feed hold
Spindle stop
Feed hold
Spindle stop
Magazine rotation disabled
Magazine rotation disabled
Feed hold
Spindle stop
Only display of alarm
Single block
Spindle stop
Feed hold
Spindle stop
Sensor Detecting
the Alarm
SP10
Centralized
lubrication unit
SL4
X03
Centralized
lubrication unit
SL4
X9A
Spindle controller
X243
KM10, KM11,
FR4, FR76,
QF7, QF8, QF13
X1A
FR13, FR113,
X1B
Main transformer
X10
Need help?