Section 3.2: Wiring; Section 3.3: General Specifications; Section 3.4: Electrical Specifications; Section 3.5: Output Power Guidelines - Nabco GT1175 Wiring And Programming Manual

Slide door opus control
Hide thumbs Also See for GT1175:
Table of Contents

Advertisement

www.NabcoEntrances.com
Rev. 8-11-21
SECTION 3.2: Wiring
Item
Power Input
Power for accessories
Output Rating
Relay Output Rating
F1 Fuse
SECTION 3.3: General Specifications
Specification
Temperature Range
Motor Type
Number of Signal Inputs
Number of Outputs
SECTION 3.4: Electrical Specifications
Note: All Wiring Diagrams included within this manual, reflect typical primary and secondary circuits that might be commonly
used. On site wiring may be different from that shown.
Note: NABCO factory utilizes Underwriters Laboratories (UL) recognized component wire, terminals and connector housings to
Table 1 Power Draw Common Accessories
manufacture all Automatic Door systems.
Sensor
BEA IXIO-DT1
Acusensor M
Optex i-oneX T
Acuzone T
Radio Control Receiver
CX33 Logic Relay
SECTION 3.5: Output Power Guidelines
TOTAL current draw from the Opus Control must not exceed 0.7A when providing power to:
Sensors
X
An auxiliary power supply, (e.g. NABCO Transformer 24 VDC Power Supply, P/N V-00022) must be utilized if TOTAL current draw
exceeds 0.7A.
The Opus Control must Not be used to power: Magnetic Locks nor Electric Locks
CAUTION
To determine if an auxiliary power supply must be used, add the total current draw of all devices. Please refer to the formula below:
1 x Cp/RX Radio Control Receiver @ 50 mA = 50 mA
100VAC - 130 VAC, AC 50-60 Hz; 3A (NABCO recommends min. 5A service)
12VDC; 750mA
Transistor Output; 100mA @ 12VDC
Mechanical Relay Output; 3A at 110VAC
120VAC Power Circuit of Control
-13 degrees to 140 degrees Fahrenheit
High voltage, Brushless Motor with Encoder, 115V
► 1 x Activation
► 2 x Safety
► 1 x Breakout (stop)
► 1 x Electric Lock Form C Relay
► 2 x Programmable Transistor Outputs
Part Number
V-00057
A-01306
V-00746
V-00745
24-11467
V-00734
Modules
X
Example: An Automatic Door System is to be fitted with the following devices:
2 x Acusensor M @ 150 mA = 300 mA
350mA does not exceed total current draw.
An Auxiliary Power Supply does not need to be used.
GT1175 Slide Door Opus Control Wiring and Programming Manual
Description
Description
200mA
150mA
208mA
208mA
50mA
320mA
Accessories
X
Total = 350 mA
► 2 x Door Mode
► 1 x Sequential
► 3 x Programmable
Current Consumption
(ea.unit) at 12VDC
Auxiliary Equipment
X
P/N C-00391