Model Number Nomenclature - Bryant LEGACY 580J Product Data

Gas heat/electric cooling packaged rooftop 3 to 15 nominal tons
Hide thumbs Also See for LEGACY 580J:
Table of Contents

Advertisement

MODEL NUMBER NOMENCLATURE

Unit Type
580J = Cooling/Gas Heat RTU
Legacy Series w/Puron Refrigerant
Voltage
E = 460--- 3--- 60
J = 208/230--- 1--- 60
P = 208/230--- 3--- 60
T = 575--- 3--- 60
Cooling Tons
04 = 3 Ton
05 = 4 Ton
06 = 5 Ton
07 = 6 Ton
08 = 7.5 Ton
09 = 8.5 Ton
12 = 10 Ton
14 = 12.5 Ton
16 = 15 Ton
Refrig. System/Gas Heat Options
A = Standard 1--- Stage Cooling models/Nat gas heat
B = Standard 1--- Stage Cooling models/Low NO
C = Standard 1--- Stage Cooling models/SS Gas HX
D = 2--- Stage Cooling models 08--- 16
F = 2--- Stage Cooling models and SS Gas HX (08--- 16)
G = 1--- Stage Cooling/Al HX w/Perfect Humidity 04--- 07
H = 1--- Stage Cooling/Low No
04--- 07
J = 1--- Stage Cooling/SS Gas HX w/Perfect Humidity
04--- 07
K = 2--- Stage Cooling/Al Gas HX w/Perfect Humidity 08-14
M = 2--- Stage Cool/SS Gas HX w/Perfect Humidity 08-14
Heat Level Input
Standard/Stainless Steel
072 = 72,000
115 = 115,000
125 = 125,000
150 = 150,000
180 = 180,000
224 = 224,000
240 = 240,000
250 = 250,000
350 = 350,000
Low NO
x
060 = 60,000
090 = 90,000
120 = 120,000
1
2
3
4
5
6
7
5 8 0 J E 0 6 A 0 7 2 A 1 A 0 A A
____________
______
heat
x
Heat w/Perfect Humidity
x
8
9
10 11 12 13 14 15 16 17
________
______
Intake/Exhaust Options
A = None
B = Temp econo w/ baro relief
E = Temp econo w/ baro relief & CO
H = Enthalpy econo w/ baro relief
L = Enthalpy econo w/ baro relief & CO
Q = Motorized 2 pos damper
Indoor Fan Options
1 = Standard static option
2 = Medium static option
3 = High static option
C = High Static Option w/High Efficiency Motor
(Size 16 only)
Coil Options
Models w/Round Tube Plate Fin (RTPF) condenser coil
(Outdoor --- Indoor --- Hail Guard)
A = Al/Cu --- Al/Cu
B = Precoat Al/Cu --- Al/Cu
C = E--- coat Al/Cu --- Al/Cu
D = E--- coat Al/Cu --- E--- coat Al/Cu
E = Cu/Cu --- Al/Cu
F = Cu/Cu --- Cu/Cu
M = Al/Cu --- Al/Cu --- Louvered Hail guards
N = Precoat Al/Cu --- Al/Cu --- Louvered Hail Guards
P = E coat Al/Cu --- Al/Cu --- Louvered Hail Guards
Q = E coat Al/Cu --- E coat Al/Cu --- Louvered Hail Guards
R = Cu/Cu --- Al/Cu --- Louvered Hail Guards
S = Cu/Cu --- Cu/Cu --- Louvered Hail Guards
Models w/All aluminum, Novation condenser coils
(Outdoor --- Indoor --- Hail Guard)
G = Al/Al --- Al/ Cu
H = Al/Al --- Cu/Cu
J = Al/Al --- E coat Al/Cu
K = E coat Al/Al --- Al/ Cu
L = E coat Al/Al --- E coat Al/Cu
T = Al/Al --- Al/Cu --- Louvered Hail Guards
U = Al/Al --- Cu/ Cu, Louvered Hail Guards
V = Al/Al --- E coat Al/Cu, Louvered Hail Guards
W = E coat Al/Al --- Al/ Cu, Louvered Hail Guards
X = E coat Al/Al --- E coat Al/Cu, Louvered Hail Guards
4
Packaging
A = Standard
B = LTL
Factory Installed Options
0A = None
2
2

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LEGACY 580J and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF