PRECAUTIONS FOR USE
Warning:
• Make sure to insert the power plug securely.
Insecure insertion of the plug may cause
electrocution or fire.
• Never unplug the machine while running.
• Do not damage the cord or use an unapproved
cord.
• Do not plug other electric appliances into the
same socket or use extension cords.
• Never operate the air conditioner with wet
hands.
• Do not pull the plug out by the cord. This could
cause the cord to overheat and catch fire.
• Turn off the air conditioner and pull out the plug
when cleaning the air conditioner. This will
prevent electrocution or injury.
• The rated voltage of this air conditioner is 220-
240V with a tolerance of ±22V for fluctuation.
The compressor will vibrate if the voltage is too
low, causing damage to the cooling system.
• If you notice anything unusual (e.g. burnt smell),
switch off the power supply immediately and
contact the Whirlpool Authorized Service
Center nearest you.
If the abnormal condition continues, the air
conditioner could be damaged and could also
cause electrocution or fire.
• Grounding: The unit must be reliably grounded.
The grounding cable must be connected to the
special grounding system in the building.
If the building does not have a grounding
system, ask an expert electrician to install one.
Never connect the grounding cable to a gas
pipe, water pipe, sewage pipe or other unless
the professional considers it reliable.
• Make sure to unplug air conditioner when not in
use for an extended period. Accumulation of
dust could cause heating or fire.
• Set the room temperature appropriately. The
difference between indoor and outdoor
temperature should be 5°C.
Appropriate adjustment of the temperature
setting serves to reduce consumption.
• When the air conditioner is running, do not
leave doors and windows open in the room.
This will prevent loss of effectiveness of the air
conditioner.
• Never block the air inlet or outlet of indoor and
outdoor unit, as this will decrease the effect of
the air conditioner or cause it to shut down or
even catch fire.
• Spray cans, chemicals and gas tanks must be
placed at least 1m away from the indoor and
outdoor unit; they could cause fire or explosion
• Make sure to mount the outdoor unit on a
sturdy base. If the base is damaged and
unsteady, the unit could fall and cause injury.
• Do not stand or place anything on the outdoor
unit. Persons or objects falling from the unit
could cause injuries.
• Do not repair the air conditioner yourself.
Incorrect repairs could cause electrocution or
fire. Contact the Whirlpool Authorized Service
Center nearest you for repairs.
• Adjust the air flow and direction properly. When
the air conditioner is running, you can adjust the
air flow direction by setting the upper/lower
guide louver position using the remote control
or handle.
• Never reach with your finger or a stick into the
indoor or outdoor unit.
• Never blow the air directly at pets or plants, as
this may harm them.
• Never spray water onto the unit or wash the air
conditioner with water.
• Never let the air conditioner blow on a heat
source. This could put the flame out and cause
carbon monoxide poisoning.
• To avoid any harm to your health, do not blow
the cold air on your body too long or lower the
room temperature too much.
• This air conditioner cannot be used for drying
clothes or chilling foods.
Warning:
• Do not cut or damage the power cords and
control lines. Any damaged power cords and
signal control lines of the air conditioner must
be replaced by qualified technicians with special
cords.
• Persistent abnormality indicates that the air
conditioner may be damaged with the
consequent risk of electric shock or fire. This
may cause an electric shock.
• To prevent fire always use a special power
supply circuit.
• Disconnect the air conditioner from the power
supply if it is to be left unused for a long period.
• For 18-23K, 230V, with a tolerable fluctuation of
±23V. The compressor is subject to strong
vibrations under very low voltages which can
damage the refrigerating system. Electrical
elements are easily damaged by high voltage.
25

Advertisement

Table of Contents
loading

Summary of Contents for Whirlpool AMD 064

  • Page 1 Incorrect repairs could cause electrocution or • Do not pull the plug out by the cord. This could fire. Contact the Whirlpool Authorized Service cause the cord to overheat and catch fire. Center nearest you for repairs. • Turn off the air conditioner and pull out the plug •...
  • Page 2 • Ensure that the power supply is suitably • Do not cut or damage the external cable. Any protected by a special circuit with air breaker. damaged external cable must be replaced by The air conditioner automatically starts or stops qualified electricians.
  • Page 3: Description Of Air Conditioner

    DESCRIPTION OF AIR CONDITIONER Indoor Unit Air inlet Air outlet Remote Control Outdoor Unit Air inlet (10) Air outlet 1. Terminal board cover plate 7. Wall pipe 2. Key switch 8. Sealing tape 3. Front panel 9. Indoor & outdoor power cord 4.
  • Page 4: How To Use The Remote Control

    HOW TO USE THE REMOTE CONTROL Operating Guideline - General Procedures 1. After the main unit is connected to power, press the ON/OFF key on the remote control to start the air conditioner. (Note: The guide louver on main unit will be closed automatically when the air conditioner is switched off).
  • Page 5 UP/DOWN UP/DOWN Key Press these two keys when in COOL, DEHUMIDIFY, FAN or HEAT mode to set a temperature between 16 and 30°C. The temperature of each mode can be stored. FAN SPEED FAN Key Press this key to change the fan speed cyclically as follows: Indicates auto speed.
  • Page 6 CLOCK CLOCK key Press to set present time and then flashes. Press to adjust the time numeral segment within 5 seconds, if you press this button for more than 2 seconds, the time will increase or decrease 10 mins per 0.5 second; if you press again when the time flashing, the flash will stop and it denotes the setting succeeded.
  • Page 7 STORAGE AND TIPS FOR USING THE RC How to insert the batteries 1. Unscrew the screw on the battery cover. 2. Gently press down on the battery cover and push in the direction of the arrow to remove, as shown. 3.
  • Page 8: Cleaning And Maintenance

    CLEANING AND MAINTENANCE Warning • Make sure to stop the unit and unplug it before cleaning your air conditioner. Otherwise you may risk electrocution. • Wetting of air conditioner may cause the risk of electrocution. Never wash your air conditioner. •...
  • Page 9 2. Check the grounding cable for reliability. 3. Check the battery of the remote control for replacement. 4. Check the mounting frame of the outdoor unit for damage. If damaged, contact a Whirlpool Authorized Service Center. Maintenance after Seasonal Use 1. Disconnect from the power supply.
  • Page 10: Troubleshooting

    Warning: Do not attempt to repair the air conditioner yourself. Incorrect repairs may cause electrocution or fire, so please contact the Whirlpool Authorized Service Center nearest you for professional repairs. The following checks may save your time and costs. Malfunction...
  • Page 11 • If the air conditioner is left running in high humidity, moisture may condense on the grill and accumulate there. In case of the following events, please contact the Whirlpool Authorized Service Center nearest you. Stop the air conditioner and •...
  • Page 12 1. Choose a place where the noise and air flow to this manual by professionals; from the fan will not affect neighbors, animals 2. Contact the local Whirlpool Service Center or or plants; qualified technician before installation; 2. Ensure good ventilation of outdoor unit;...
  • Page 13: Electrical Safety Requirements

    ELECTRICAL SAFETY REQUIREMENTS 1. The power supply must be of rated voltage with Other: special circuitry for air-conditioning. The 1. The connection between the air conditioner diameter of the power cord must comply with and power cables and the connection between requirements.
  • Page 14 From the Wall Over 15 cm Over 15 cm From the Wall Above the floor Air intake side AMD 064 AMD 065 50 cm or more Space to the cover 50 cm or more Space to the cover 30 cm or above...
  • Page 15: Installing Indoor Unit

    INSTALLING INDOOR UNIT Installing Wall-Mount Frame 1. Level with plumb line or spirit level. As the drain outlet is on the left side, it is better for the left side to be lower when adjusting the wall-mounted board; 2. Use screws to secure the wall-mount frame on the wall; 3.
  • Page 16 Connection of Indoor and Outdoor Cables 1. Pull open the front panel; Covering plate 2. Unscrew the screw fastening the covering plate on terminal board. (See Fig. 1); Power 3. Pass the power cable through a separate cable duct on Connection the back of indoor unit and pull it out from the front;...
  • Page 17 Installing Connecting Pipe 1. The tapered end of the connecting pipe must be in line with the corresponding tape face of the valve joint. 2. Tighten the nut manually on the connecting pipe and then use a wrench to tighten it fully. Caution: Excess torque may damage the nut.
  • Page 18: Installing Outdoor Unit

    INSTALLING OUTDOOR UNIT Cable connection For AMD 064: Connecting diagrams for oudoor and indoor unit 1. Remove the handle on the right side plate of the outdoor unit (one screw). Handle 2. Remove the cable clamp, connect the power connection cable with the terminal on the connecting board and fasten it.
  • Page 19 For AMD 065: Connecting diagrams for oudoor and indoor unit 1. Disassemble the front side plate on the outdoor unit front side plate (4pc screw). 2. Remove the cable clamp, Back side panel connect the power connection Front side panel cable with the terminal on the connecting board and fasten it.
  • Page 20 Installing the pipes Install the drain fitting and the drain hose (for model with heat pump only). Condensation is produced and flows from the outdoor unit when the appliance is operating in the heating mode. In order not to disturb neighbours and to respect the environment, install a drain fitting and a drain hose to channel the condensate water.
  • Page 21 CHECKS AND TEST RUN AFTER INSTALLATION Check Items After Installation Check items Problems caused to improper installation Is the installation secure? The unit may fall, vibrate or make noise Has gas leakage been checked? May cause unsatisfactory cooling (heating) effect Is the thermal insulation of the unit sufficient? May cause unsatisfactory cooling (heating) effect Is drainage smooth?

Table of Contents