German pool EFB-PCTH User Manual page 10

Uv-c air purifier heater & fan
Table of Contents

Advertisement

Troubleshooting
WARNING!
Before maintenance work, turn off the product and unplug product from power source.
This product must be installed and repaired by the manufacturer's authorized after-sales personnel
only; if consumers entrust personnel not designated by the manufacturer, or if consumers perform
reparation work on their own, there may be a risk of personal injury or property loss.
PROBLEM
POSSIBLE REASON
Has plugged in power but the
Is the plug properly inserted into the socket?
product does not work
Is the battery dead?
Remote Control does not work
Is the battery inserted correctly?
Is the Remote Control aligned with the Signal Receiver?
Error Code
CODE
PROBLEM
POSSIBLE REASON
E1
Under Voltage
Induced by voltage too low
Protection
220V fan connected to 110V voltage
Under bad AC terminal block connection during operation of
fan, voltage of the electronic board may go too low
Pulling the plug when fan is operating at high speed. This is
because fan motor is still heated so electronic board takes
time to drop its electricity, inducing this problem. This is natural
occurrence. When plugged again, the fan will operate normally.
Electronic board defect
E2
High Voltage Pro-
Induced by voltage too high
tection
110V fan connected to 220V voltage
Electronic board defect
P.18
Troubleshooting
E3
Blocked Rotor
Rotor installed incorrectly, fan blade blocked
Poor connection between rotor terminal block and
electronic board
Rotor defect or disconnection
Rotor terminal block of the electronic board defect, poorly weld-
ed or terminal block pin missing
Electronic board defect: circuit driver, power component (MOS-
FET) or other components damaged by outer forces, Electronic
board parameter error
E4
Hardware
Short circuit of fan rotor or inner rotor
Overcurrent
Electronic board defect: driver error or power component (MOS-
FET) error
Incorrect rotor usage: using low voltage rotor on
high voltage driver
E5
Software
Electronic board defect: current sampling circuit error
Overcurrent
E6
Default Phase
Rotor disconnection
of Rotor
Poor connection between rotor and terminal block
Electronic board defect: driving error of driver
E7
Communication
Poor communication between display board and mother board,
Error
poor cable connection, cable terminal block installation error
Usage of display board with non-updated programme, matching
error with new mother board
Poor welding of electronic board terminal block
E8
Machine Tilting
Machine placed at an angle of ≥30 degrees
against the surface
Tipping Switch defect, electronic board defect
E9
Temperature-sensor
Temperature-sensor probe plug-in failure
probe not connected
Electronic board defect
Temperature-sensor probe defect