Replacing Fuses
If the unit does not function at all when connected to the main power supply i.e. does not illuminate
after replacing the lamp. Then it is highly likely that the fuse has blown.
Disconnect from main power supply before attempting to replace either lamps or fuse.
In order to replace the fuse, disconnect from the main power supply first, and then unscrew the
fuseholder cover to reveal the fuse. The unit has a label attached which indicates the correct fuse
rating and you will also find this listed as part of the specifications for the unit later in this guide. It is
most important that replacement fuses are of the correct rating. Failure to use the correct fuse could
damage the lighting effect beyond economic repair.
The fuse should simply be placed inside the holder and the screw cap replaced, when this is done
connect to the main power supply to check. If the unit is still not working then please CHAUVET for
servicing.
Caution
Do not touch unit or lamps while hot.
No user serviceable parts inside, please refer to CHAUVET for service.
Power Connections
The unit is supplied with a power plug appropriate to its voltage and destination. Should any other
connections be required they must be carried out with the following configuration.
Earth = Green/Yellow cable
Neutral = Blue cable
Live = Brown cable
In the USA & Europe, it is required that all plugs are 3-pin type i.e. with Earth/Ground connection.
In the UK, it is required that all mains plugs are fitted with 5A fuses.
Packing List
Please check contents of your packaging carefully for the following items:
1 x CH-214 Tetra (Master Head)
3 x CH-214 Tetra (Linkable Heads)
4 x 64514 / 64516 Lamps
3 x 3m (10') linking cables
1 x Literature – user guide / warranty card
Technical Specifications
Power
120V~60Hz AC
Fuses
20mm Glass 3.15A Quick Blow
o
2 x 5-pin (180
) DIN twistlock
Control In/Out
sockets
1 x 120V 300W
Lamps
Part No 64514
Dimensions
300 x 280 x 180mm / 12in x 11in x 7in
Weight
230V~50Hz AC
20mm Glass 1.6A Quick Blow
o
2 x 5-pin (180
) DIN twistlock
sockets
1 x 230V 300W
Part No 64516
3.13kg / 7lbs
Te t r a
CH-214
Users Guide
Please read these instructions carefully before use
World-wide Headquarters:
3000 North 29
Hollywood, FL 33020
Tel: +1-954-929-1115 Fax: +1-954-929-5560
www.ChauvetLighting.com
Ct.
th

Advertisement

loading
Need help?

Need help?

Do you have a question about the CH-214 and is the answer not in the manual?

Questions and answers

Summary of Contents for Chauvet CH-214

  • Page 1 The fuse should simply be placed inside the holder and the screw cap replaced, when this is done connect to the main power supply to check. If the unit is still not working then please CHAUVET for servicing.
  • Page 2 Finally before switching on, check that the lamp is housed correctly in the lamp holder and that the lamp replacement cover has been screwed back into place. If after replacement of the lamp, the unit is still not working then please contact CHAUVET for servicing.

This manual is also suitable for:

Tetra