Download Print this page
Sealey WPP1100 Quick Start Manual

Sealey WPP1100 Quick Start Manual

Submersible pond pump 1100ltr/hr 230v

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Warning!
instructions
Electricity
1. SAFETY
1.1.
ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and
any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate
safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend
that a Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into
a supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device
by contacting your Sealey stockist.
IMPORTANT: You must also read and understand the following instructions concerning electrical safety:
1.1.1.
The Electricity at Work Act 1989 requires that all portable electrical appliances, if used on business premises, are tested by a
qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.
The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances
1.1.2.
and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3.
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2.
and use a Portable Appliance Tester.
1.1.4.
Ensure that cables are always protected against short circuit and overload.
1.1.5.
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure
that none is loose.
1.1.6.
IMPORTANT: Ensure that the voltage marked on the appliance matches the power supply to be used
and that the plug is fitted with the correct fuse - see fuse rating at right.
DO NOT pull or carry the appliance by the power cable.
8
DO NOT pull the plug from the socket by the cable.
8
DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty item repaired
8
or replaced by a qualified electrician. When a BS 1363/A UK 3 pin plug is damaged, cut the cable just
above the plug and dispose of the plug safely.
1.2.
Fit a new plug according to the following instructions (UK only).
a)
Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b)
Connect the BROWN live wire to the live terminal 'L'.
c)
Connect the BLUE neutral wire to the neutral terminal 'N'.
d)
After wiring, check that there are no bare wires, that all
wires have been correctly connected, that the cable outer
insulation extends beyond the cable restraint and that the
restraint is tight.
1.2.1.
Double insulated products, which are always marked with this symbol
, are fitted with live (brown) and neutral (blue) wires only.
1.2.2.
To rewire, connect the wires as indicated above - DO NOT connect
either wire to the earth terminal.
IMPORTANT: Products which require more than 13amps are supplied
without a plug. In this case you must contact a qualified electrician to
ensure that a suitably rated supply is available. We recommend that
you discuss the installation of an industrial round pin plug and socket
with your electrician.
1.2.3.
If an extension reel is used it should be fully unwound before
connection. A reel with an RCD fitted is preferred since any appliance
plugged into it will be protected. The cable core section is important
and should be at least 1.5mm², but to be absolutely sure that the
capacity of the reel is suitable for this product and for others which
may be used in the other output sockets, we recommend the use
of 2.5mm² section cable. If an extension reel is to be used outdoors,
ensure it is marked for outdoor use.
© Jack Sealey Limited
SUBMERSIBLE POND PUMP 1100LTR/HR 230V
WPP1100
MODEL NO:
Original Language Version
Replacement fuse
rating: 13AMP
WPP1100 | Issue 6 (H,F,2,3) 28/02/2019

Advertisement

loading

Summary of Contents for Sealey WPP1100

  • Page 1 WPP1100 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 3. SPECIFICATION Model No: ....... . .WPP1100 Cable Length: ........10m Fountain Effects:.
  • Page 3 Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...