E-CON Ver. 1.20 Software for the ALGEBRA FX 2.0 Series 1. E-CON Overview 2. EA-100 Setup 3. Setup Memory 4. Program Converter 5. Starting a Sampling Operation All of the explanations provided here assume that you are already familiar with the operating precautions, terminology, and operational procedures of the calculator and the EA-100.
• 6(HELP) ... Displays E-CON help. • Pressing the K key (Setup Preview) or a cursor key while the E-CON main menu is on the screen displays a preview dialog box that shows the contents of the setup in the current setup memory area.
2. EA-100 Setup You can use the E-CON Mode to set up the EA-100 for sampling and then start sampling immediately or save the setup in calculator memory. You can use either of the following two methods to set up the EA-100.
Page 4
4. Press any key to start Setup Wizard and display the sensor specification screen. • Press 1 to specify a CASIO sensor, or 2 to specify a VERNIER sensor. From the menu of supported sensors that appears, select the one you want.
Page 5
• 4(PRGM) ... Converts the setup to a program (page 4-1). • Pressing 2(NO) in step 7 returns to the E-CON main menu and stores the setup in the E-CON Mode’s current setup memory area. You can use the following function key operations from the E-CON main menu to manipulate the contents of the current setup memory area.
Page 6
The following procedure describes the general steps for using Advanced Setup. Refer to the pages as noted for more information. 1. Display the E-CON main menu. 2. Press 1(SETUP). This displays the “Setup EA-100” sub-menu. 3. Press c(Advan). This displays the Advanced Setup menu.
Page 7
• You can return the settings on the above setup screens (b through e) using the procedure described under “To return setup parameters to their initial defaults”. 6. After you create a setup, you can use the function key operations described below to start sampling or perform other operations.
Page 9
Sample Selecting this parameter displays a screen for making real-time settings, and for specifying the sampling interval, number of samples, measurement time recording method, and storage location for measurement time records. • To change Sample Setup settings 1. While the Advanced Setup menu is on the display, press c(Sample). •...
Page 10
(4) Measurement Time Recording Method (Rec Time) • 1(None) ... No time recorded. • 2(Abs) ... Absolute time in seconds from start of sampling • 3(Rel) ... Relative time (interval between samples) in seconds • 4(Int A) ... Absolute time calculated from sampling interval and number of samples •...
Page 11
2. Use the function key operations described below to change Trigger Setup settings. • To change the setting of an item, first use the f and c cursor keys to move the highlighting to the item. Next, use the function keys to select the setting you want. (1) Trigger Source (Source) •...
Page 12
Option Use the Option Setup screen to make View Window settings, to specify the channel for real- time sampling, and to make filter settings. • To change Option Setup settings 1. While the Advanced Setup menu is on the display, press e(Option). •...
Page 13
You can use either of the two following procedures to create a new custom probe configuration while creating an EA-100 setup using Advanced Setup. The term “custom probe” means any sensor other than the CASIO or VERNIER sensors specified as standard for the E-CON Mode. 2-11 EA-100 Setup c(9-p): 9-point...
Page 14
• To configure a custom probe starting from the Advanced Setup menu 1. From the E-CON main menu, press 1(SETUP) and then c(Advan) to display the Advanced Setup menu. • See “Creating an EA-100 Setup Using Advanced Setup” on page 2-4 for more information.
Page 15
• To configure a custom probe starting from the Channel parameter setting screen 1. From the E-CON main menu, press 1(SETUP) and then c(Advan) to display the Advanced Setup menu. • See “Creating an EA-100 Setup Using Advanced Setup” on page 2-4 for more information.
Page 16
u To use the MULTIMETER Mode You can use the Channel parameter settings of Advanced Setup to configure a channel so that EA-100 MULTIMETER Mode sampling is triggered by a calculator operation. 1. Use the Channel parameter setting Sensor item to configure a sensor. •...
• While the E-CON main menu is on the display Performing the setup save operation while the E-CON main menu is on the display saves the contents of the current setup memory area (which were created using Setup Wizard or Advanced Setup).
Page 18
You can use the following procedure to check the contents of a setup before you use it for sampling. 1. On the E-CON main menu, press 2(MEM) to display the setup memory list. 2. Use the f and c cursor keys to highlight the name of the setup you want.
Page 19
• To recall a setup and use it for sampling 1. On the E-CON main menu, press 2(MEM) to display the setup memory list. 2. Use the f and c cursor keys to highlight the name of the setup you want.
Page 20
To delete setup data 1. On the E-CON main menu, press 2(MEM) to display the setup memory list. 2. Use the f and c cursor keys to highlight the name of the setup you want. 3. Press 4(DEL). 4. In response to the confirmation message that appears, press w to delete the setup.
• While the E-CON main menu is on the display Performing the program converter operation while the E-CON main menu is on the display converts the contents of the current setup memory area (which were created using Setup Wizard or Advanced Setup).
Page 22
3. Press w. • This starts conversion of the setup data to a program. • The message “Complete!” appears when conversion is complete. u To convert setup data to a program and transfer it to a CFX-9850 Series/ fx-7400 Series calculator 1.
5. Starting a Sampling Operation The section describes how to use a setup created using the E-CON Mode to start an EA-100 sampling operation. k Before getting started... Be sure to perform the following steps before starting sampling with the EA-100.