Wiring the Controller

Solenoids
Each of the solenoids must be connected
to the board inside the controller, as shown
in Figures 11, 12.
DC models: The black wire from each
solenoid should be attached to the
common terminal (C) as shown in Figure
11. The red wires should be attached as
shown to terminals Out A and Out B
respectively.
AC models: The solenoid wires will be
the same color. One wire from each
solenoid should be attached to the
common terminal (C), and the other wires
from each solenoid connected to terminals
Out A and Out B see Figure 12.
Figure 11 Wiring for DC Solenoids
Figure 12 Wiring for AC Solenoid