1 Scope
These application notes are a guide to applying the G123-815
Buffer Amplifier. They tell you how to install, connect and
adjust the Buffer Amplifier. They do not tell you how to design
the closed loop system in which it is used.
2 Description
The G123-815 Buffer Amplifier interfaces between standard
PLC analogue input and output modules, on one side, and
a position transducer and a Moog valve, on the other.
It simplifies the use of a PLC in closing position loops.
The Buffer Amplifier solves the common problem of the
±10V PLC output being incompatible with the valve drive
requirements. It also provides digital noise filtering for the valve
signal and noise filtering for the position transducer signal.
For a more detailed description, see Moog brochure
G123-815E01.01.
3 Installation
3.1 Placement
A horizontal DIN rail, mounted on the vertical rear surface of
an industrial steel enclosure, is the intended method of
mounting. The rail release clip of the G123-815 should face
down, so the front panel and terminal identifications are
readable and so the internal electronics receive a cooling
airflow. An important consideration for the placement of the
module is electro magnetic interference (EMI) from other
equipment in the enclosure. For instance, VF and AC servo
drives can produce high levels of EMI. Always check the EMC
compliance of other equipment before placing the G123-815
close by.
3.2 Cooling
Vents in the top and bottom sides of the G123-815 case
provide cooling for the electronics inside. These vents should
be left clear. It is important to ensure that equipment below
does not produce hot exhaust air that heats up the G123-815.
m
Top vents
13
9
BUFFER AMP
1
5
Bottom
vents
3.3 Wiring
The use of crimp "boot lace ferrules" is recommended for the
screw terminals. Allow sufficient cable length so the circuit
card can be withdrawn from its case with the wires still
connected. This enables switch changes on the circuit card to
be made while the card is still connected and operating.
An extra 100mm, for cables going outside the enclosure,
as well as wires connecting to adjacent DIN rail units, is
adequate.
Enclosure
Grounded EMI
cable gland
Cable
Radial screen
termination
Preferred Wiring
Buffer Amplifier
G123-815
Cover
release
tab (2)
Screw
terminals
9 - 16
14
15
16
10
11
12
DIN rail
probe
Iv
valve
Vv
0V
2
3
4
Screw
6
7
8
terminals
1 - 8
DIN rail
release
clip
Cooling
airflow
Wires
100mm Loop
Page 1 of 4: C31885 Rev B 10.03

Advertisement

loading
Need help?

Need help?

Do you have a question about the G123-815 and is the answer not in the manual?

Questions and answers

Summary of Contents for Moog G123-815

  • Page 1 An extra 100mm, for cables going outside the enclosure, as well as wires connecting to adjacent DIN rail units, is Vents in the top and bottom sides of the G123-815 case adequate. provide cooling for the electronics inside. These vents should be left clear.
  • Page 2 Hz, where T = the sum of mS period switches selected 3.4 EMC 5.2 Low Rin The G123-815 emits radiation well below the level called for in its CE mark test. Therefore, no special precautions are required The “low Rin” switch drops the input resistance for the PLC for suppression of emissions.
  • Page 3 8 Block-wiring diagram +24V Supply +15V +24V Voltage Amplifier -15V Power Supply see note 1 Valve Command Filter valve 0.22mS (723Hz) 2.2mS (72Hz) +24V see note 2 Current Amplifier 4.7mS (34Hz) Filter Valve select Output select 10mS (16Hz) switches see v alve wiring diagrams (4 switches) 10mA...
  • Page 4 Moog Australia Pty. Ltd. Telephone: 03 9561 6044. Fax: 03 9562 0246. Moog pursues a policy of continuous development and reserves the right to alter designs and specifications without prior notice. Information contained herein is for guidance only and does not form part of a contract.