Page 2
• Manual created • Changed D15 to D20 throughout Changed coverage diagram for D20 (but not PET) 09-10-2020 • Changed Pet mode coverage and updated all drawings to reference D20 instead of D15 • Changes made in relation to PCR01383 •...
Page 4
1.0 Quick installation 1.1 Opening the device The devices are supplied in the unlocked position. If locked. Use a flat bladed terminal driver and turn the locking mechanism ¼ turn anti- clockwise. Slide the front down and towards you to remove. For ceiling mount devices remove the facia by turning it anti-clockwise, and then unlock as above.
Page 8
1.2 Mounting and cable entry Location Ensure you have the correct device for the intended application, and that it is sited correctly in the desired location. The field of view should be free from obstacles and any potential false alert causes. Devices should be mounted on stable internal surfaces and are NOT suitable for use externally.
Page 9
Ensure the devices field of view is not obstructed INS878EN-2 9/68...
Page 10
Install on a flat stable surface only INS878EN-2 10/68...
Page 11
Ensure surrounding structures are stable INS878EN-2 11/68...
Page 12
For internal use only Screws & Fixings A minimum of 2 opposing fixing holes should be used to ensure maximum stability. When corner mounting care should be taken to ensure the chassis is not twisted, if the corner is uneven then two fixings on the same side would be acceptable. Where removal from mounting detection is required you must ensure that the tamper fixing is opposite to at least one of the corner or wall fixings.
Page 13
passes around the post as shown. This helps avoid cable snagging when refitting the front chassis. NOTE: Do not use the screw fixing points to route cable. Corner mount Wall, ceiling & flat surface mount INS878EN-2 13/68...
Page 18
Premier Elite control panel. For other wiring types, please refer to the manufacturer’s instructions for your equipment. The device is defaulted to the Texecom EOL values. Use a terminal driver to move the switch to any other position.
Page 20
EOL wiring to a Premier Elite 24 & 64-W INS878EN-2 20/68...
Page 21
EOL wiring to a Premier Elite 48 & 640 INS878EN-2 21/68...
Page 22
RLED terminal The RLED (Remote LED) terminal can be used to control the LED for walk testing INS878EN-2 22/68...
Page 23
To use the RLED feature put switch 1 in the up position which will disable the LED. When an output is triggered 0V is applied to the RLED terminal which will enable the LED. On a Texecom control panel the output can be programmed as either Engineer Logon or Walktest.
Page 24
Pet Mode (P15, Q20 & D20) When using Pet mode, switch 2 and the lens obscuration slider should both be placed in the UP position. P15 10mtr @ 90° up to 35kg Q20 12mtr @ 90° up to 20Kg pet immunity compliant to PD6662 & EN50131-2-2 D20 12mtr @ 85°...
Page 25
CloakWise™ D20 & CD CloakWise is a proprietary detection algorithm, unique to Texecom, that can distinguish the presence of an intruder even if the unauthorised person attempts to mask or ‘cloak’ their presence. Utilising advanced signal processing techniques to both microwave and PIR channels, the CloakWise technology can recognise cloaking attempts and detect accordingly.
Page 26
Low ceiling mount CQ & CD only Low mode lowers the sensitivity of the device and provides greater false alarm immunity. Thorough walk testing across the entire protected area should be carried out to ensure catch performance is as expected. Note: Never use CloakWise with LOW mode.
Page 27
CQ & CD Slider Leave in the default position INS878EN-2 27/68...
Page 29
1.5 Testing, commissioning & LED indications When installation is complete, the device should be thoroughly walk tested to ensure the desired protection is being achieved, and any adjustments to the device are made to cater for the specific location and any local site conditions. Note: LED’s are disabled during normal use if the RLED switch is ON.
Page 31
Resistance and voltage readings should be recorded at the time of installation. Voltage readings should be taken at the device Resistance reading should be taken at the CIE or ACE where the circuit is terminated. 2.0 Variants 2.1 CAPTURE P15 INS878EN-2 31/68...
Page 56
Microwave DO NOT USE 3.0 Accessories INS878EN-2 56/68...
Page 57
3.1 Branding Branding is available for wall mount devices from our website CLICK HERE consists of a printed insert and a clear cover which fits over the front of the device and holds the insert in place. Note: The cover should be removed before sliding the front of the device off for servicing or adjustment.
Page 61
3.2 Optional wall or ceiling mount brackets Part Numbers Pack of 10 brackets AFU-0004 Screws & Fixings To ensure maximum stability 2 screws should be used for either mounting option. Dependent on the mounting substrate, suitable fixings may be required. The size and type will depend on the choice of fixing screw.
Page 66
4.0 Specifications Specification P15, Q20, D20, CQ, CD EN50131-2-2 (P15, Q20, CQ) EN50131-2-4 (D20, Alarm System CD), EN50131-1, PD6662:2017 Grade 2 Class II AKBA0000 (P15) AKCA0000 (Q20) Product Type AKDA0000 (D20) AKFA0000 (CQ) AKGA0000 (CD) Operating 9-15Vdc (12V + - 25%) Voltage Maximum P15, Q20, CQ –...
Page 67
Ceiling Mount: 125mm Diameter, Depth 43mm. 5.0 Legal information 5.1 Supplier Texecom Ltd, Haslingden, Lancashire, BB4 4PW, UK. Made in England 5.2 WEEE Directive 2012/19/EU (WEEE Directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. To recycle, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points.
Page 68
Test yearly by the installer 5.4 Warranty Limited lifetime warranty. As the Capture P15, Q20, D20, CQ, CD is not a complete alarm system, but only a part thereof, Texecom cannot accept responsibility or liability for any damages whatsoever based on a claim that the Capture P15, Q20, D20, CQ, CD failed to function correctly.