Cabinet Collector Series 50-90 Models 54, 64, 66, 75, 81, 84, 90 Installation and Operation Manual Installation, Operation, and Service Information Models 54-84 Shown This manual is property of the owner. Leave with the collector when set-up and start-up are complete. Donaldson Company reserves the right to change design and specifications without prior notice.
Page 2
Installation and Operations Manual. For a replacement manual, contact Donaldson Torit. This manual contains specific precautionary statements relative to worker safety. Read thoroughly and comply as directed. Discuss the use and application of this equipment with a Donaldson Torit representative. Instruct all personnel on safe use and maintenance procedures.
Consult and comply with all National and Local Codes related to fire and/or explosion properties of combustible materials when determining the location and operation of all dust, fume, or mist collection equipment. Standard Donaldson Torit equipment is not equipped with fire extinguishing or explosion protection systems.
Cabinet Collector, Models 54-90 Rating and Specifications 55-Gallon Drum Pack 5-Gallon Pail Pack Cabinet Models 54-84 Cabinet Base Front View Typical Front View Typical Front View Typical Side View Side View Side View Cabinet Model 90 60° SLOPE ON FILTER HOPPER SECTION DUST...
Donaldson Company, Inc. Operation During normal operation, dust-laden air enters the The filtered air flows up through the center of the collector through the dirty-air inlet and passes through filters and into the clean-air chamber. Clean, filtered air the collector where the dust collects on the outside discharges through clean-air outlet located on top of the surface of the filter media.
Turn power off and lock out electrical 6. Report incomplete shipments to the delivery carrier power sources before performing service or and your Donaldson Torit representative. maintenance work. 7. Remove crates and shipping straps. Remove loose Do not install in classified hazardous...
Donaldson Company, Inc. Rigging Instructions Collector Location Donaldson Torit equipment is not Suggested Tools & Equipment designed to support site installed Clevis Pins and Clamps Lifting Slings ducts, interconnecting piping, or electrical Crane or Forklift Pipe Sealant services. All ducts, piping, or electrical...
Donaldson Company, Inc. Standard Equipment Electrical Wiring Electrical installation, service, Provisional Anchor Bolt Recommendations or maintenance work must be performed by a qualified electrician and 1. Consider Hilti HIT-HY 200 Anchor System or comply with all applicable national and local equivalent.
Cabinet Collector, Models 54-90 Preliminary Start-Up Check Instruct all personnel on safe use and maintenance 5. Check that fan exhaust damper (if provided) is set to procedures. the fully-closed position. Electrical work during 6. Check and remove all loose items in or near the inlet installation, service or and outlet of the collector.
Donaldson Company, Inc. Maintenance Information Filter Removal and Installation Instruct all personnel on safe use and maintenance Use proper safety and protective procedures. equipment when removing contaminants and filters. Use proper equipment and adopt all safety precautions needed for Dirty filters may be heavier than they appear. servicing equipment.
Cabinet Collector, Models 54-90 EZ Filter Pack Removal - Models 54-84 1. Remove upper door and open lower door. 4. Allow the filter pack to collapse in the center and remove it by guiding it out the bottom side of the sealing frame.
Page 14
Donaldson Company, Inc. 8. Important - place one hand under center of EZ 5. Rest banded EZ Filter Pack on shaker bar. Filter Pack. Holding EZ Filter Pack against bottom of cabinet ledge, push each slide latch over cabinet ledge. Do not tighten wing screws at this time.
Cabinet Collector, Models 54-90 Filter Removal - Model 90 11. Place support bar over center of EZ Filter Pack 1. Remove upper and lower doors to access the filters. 2. Loosen both set screws on the front and rear hold down brackets.
Page 16
Donaldson Company, Inc. 5. Insert rear filter inserter as shown with long arm 7. Install the front filter inserter with the long arm towards the front. Insert the right angle plate as towards the back as shown and the angle brackets shown BETWEEN two filters.
Cabinet Collector, Models 54-90 Filter Installation - Model 90 9. Remove the filter that is between the filter inserts. 1. Install the bags into the collector. All but the last bag should be able to be installed easily. 2. Slide the rear hold down bar beneath the set screws at the back of the collector.
Page 18
Donaldson Company, Inc. 4. Swing the long arm of the filter inserter from left 6. Swing the long arm of the filter inserter from right to right to open a space around the filter that the to left while keeping the inserter tight to the front of inserter is straddling.
Cabinet Collector, Models 54-90 10. To make sure all bags are sealed properly, shine a 8. Install the front hold down bar. light up between each set of filters. If no light can be seen from the top side, the bags are properly sealed. If light can be seen, insert the filter inserter inside the bag with the bent frame to expand the inside width of the bag.
Donaldson Company, Inc. Optional Equipment cabinet Hopper see Detail A 1. Attach legs and cross bracing to hopper using 3/8- 16 x 1-in bolts, washers, and nuts as shown. Cross braces can be installed to allow front or back hopper access.
Page 21
Cabinet Collector, Models 54-90 See Detail A See Detail B hopper cross brace two, 2 x 50.62-in Front View Side View cabinet 3/8-in flat washer 3/8-16 x 1-in bolt 3/8-in flat washer 3/8-16 x 1-in bolt sealant hopper 3/8-in flat washer 3/8-16 hex nut Detail A Detail B...
Donaldson Company, Inc. 5-Gallon Pail Pack 55-Gallon Drum Pack 1. Apply sealant to the hopper flange or the pail cover The drum pack is designed to fit a customer-supplied, mounting plate flange toward the inside edge of the standard 55-gallon drum and provides easy access for bolt pattern.
Cabinet Collector, Models 54-90 Hopper Attachments 5- or 55-Gallon Drum Packs with or without Slide Gate 2. Fasten the drum cover assembly to the hopper flange 1. Apply 1/4-in diameter rope-type sealant to the drum using the hardware supplied. cover mounting plate flange. hopper flange sealant drum or pail cover...
Donaldson Company, Inc. Indoor Exhaust Deflector 1. Remove the top door assembly and set aside. 4. Position the indoor exhaust deflector on the cabinet top and fasten using eight 1/4-20 thread-cutting 2. Place a piece of non-combustible cloth over the screws.
Cabinet Collector, Models 54-90 Outdoor Exhaust Deflector 1. Remove the top door assembly and set aside. 4. Position the outdoor exhaust deflector on the cabinet top, align holes and fasten using eight #10-24 x 1/2-in 2. Place a piece of non-combustible cloth over the bolts, washers, and nuts supplied.
Donaldson Company, Inc. Ductwork If collector is operated with more than the maximum permissible inlet size, the fan motor can overload or dust can settle in the duct due to low air velocity. 1. Inlet collars can be located on the side, top, or back of the cabinet by removing the desired inlet cover plate and installing the inlet collar using the same screws.
Cabinet Collector, Models 54-90 Magnehelic Gauge ® The Magnehelic is a differential pressure gauge used 3. Attach the mounting bracket using three, #6-32 x 1/4- to measure the pressure difference between the clean- in screws supplied. air and dirty-air plenums and provides a visual display 4.
Donaldson Company, Inc. Outrigger Pack Note: Outrigger pack is for use with dust drawer 2. Fasten the four mounting tabs to the outrigger base models only. using four 5/16-18 x 4-in bolts, washers, and nuts. Tighten securely. Outriggers are standard for Model 90. 3.
Cabinet Collector, Models 54-90 HEPA Filter Models 60 and 70 6. Remove HEPA filter pack and apply silicone sealant 1. Position the HEPA filter pack on top of the collector around mounting surface. as shown. 7. Fasten angle bracket to cabinet using four 2.
Page 30
Donaldson Company, Inc. Model 80 1. Remove the top door assembly and set aside. 5. Position the HEPA filter pack on top of the collector aligning holes. 2. Place a piece of non-combustible cloth over the filters in the clean-air chamber to protect them from 6.
Cabinet Collector, Models 54-90 Exhaust Silencer If an exhaust silencer was ordered with the collector, the 3. Use a .116-in diameter drill bit to drill eight holes in mounting holes are pre-drilled. the collector top as shown. To install an add-on silencer: 4.
Donaldson Company, Inc. Attenuator If an attenuator was ordered with the collector, the 3. Use a .213-in diameter drill bit to drill eight holes in mounting holes are pre-drilled. the collector top as shown. To install an add-on attenuator: 4. Position the attenuator assembly, align holes, and fasten securely using eight 1/4-20 thread-cutting 1.
Cabinet Collector, Models 54-90 Chamber Silencer 1. Place the chamber silencer over the clean-air outlet on top of the collector. 2. Position silencer flush with the front of the collector and the exhaust opening facing the front. 3. Secure with all latches. Front latch Chamber Silencer (only available on Models 54-84)
Donaldson Company, Inc. Troubleshooting Problem Probable Cause Remedy Improper motor wire size Rewire using the correct wire gauge as specified by Fan blower and motor do not start national and local codes. Not wired correctly Check and correct motor wiring for supply voltage. See motor manufacturer's wiring diagram.
Page 35
Cabinet Collector, Models 54-90 Problem Probable Cause Remedy Insufficient airflow Collapsed or plugged duct Clean duct of all debris. Replace collapsed duct. Improper duct sizing Contact installer of dust collection equipment. EZ Filter Pack plugged Shake filter packs a minimum of once a day. Brush or manually clean filter packs plugged with sticky or fibrous material.
Donaldson Company, Inc. Collector Information (Process Owner to complete and retain for your records) Model Number _____________________________ Serial Number ______________________________ Ship Date _________________________________ Installation Date _____________________________ Filter Type ____________________________________________________________________________ Dust Being Collected ___________________________________________________________________ Dust Properties: Kst _______________Pmax ______________ MIE ____________ MEC __________________ Accessories __________________________________________________________________________ Other ________________________________________________________________________________ ____________________________________________________________________________________...
Cabinet Collector, Models 54-90 Service Notes Date Service Performed Notes...
Page 38
The Donaldson Torit Warranty Donaldson warrants to the original purchaser that the major structural components of the goods will be free from defects in materials and workmanship for ten (10) years from the date of shipment, if properly installed, maintained and operated under normal conditions. Donaldson warrants all other Donaldson built components and accessories including Donaldson Airlocks, TBI Fans, TRB Fans, Fume Collector products and Donaldson built Afterfilters for twelve (12) months from date of shipment.
Need help?